Fixed
Fri Jul 7 18:04:58 2017
e748
OFFLINE
General
Kinematic Line12Be(d,3He)11Li
Fixed
e748
Sat Jul 8 16:39:00 2017
e748
RUN
General
CD2
Stop run 372 - CHIO digitizer lost parameters
Fixed
e748
Sat Jul 8 16:41:57 2017
e748
RUN
General
CD2
Run 373
Restart after rewriting parameters onto CHIO
digitizer
Same conditions as previous run
Fixed
e748
Sat Jul 8 17:04:25 2017
e748
RUN
General
CD2
RUN 374
We stopped run 373 to check the MUVI scalers
on the DAS.
We wrote the parameters onto the CHIO digitizer
Fixed
e748
Sat Jul 8 19:41:25 2017
e748
RUN
General
CD2
Run 374 (file change)
19:29 data file change -> run_0374.dat.08-07-17_16h57m56s.2
Previous change : 18:11 -> run_0374.dat.08-07-17_16h57m56s.1
Fixed
e748
Sat Jul 8 20:49:48 2017
e748
BEAM
General
CD2
Beam position on target
The beam spot on target has shifted upwards
by ~3 mm since beginning of 10Be run (see
run 366 and attached plot from run 374, July
Fixed
e748
Sat Jul 8 21:04:07 2017
e748
BEAM
General
CD2
Update: beam position on target
At ~21:00 we called PCP: They adjusted the
DC41VE steerer to center vertically the beam
on our target.
Fixed
e748
Sat Jul 8 21:53:58 2017
e748
BEAM
General
CD2
Scalers run 374
Counting rates keep decreasing though the
primary is still ~4.5 uAe and the beam is
centered on our target.
Fixed
e748
Sat Jul 8 23:22:18 2017
e748
BEAM
General
CD2
Update on counting rates + scalers
18O 4.5 uAe
CATS1 91 kcps
CATS2 114 kcps
Fixed
e748
Sun Jul 9 16:37:21 2017
e748
CHIO
General
CD2
CHIO digitizer out
CHIO digitizer was out in run 378
Fixed
e748
Sun Jul 9 16:43:40 2017
e748
OFFLINE
General
CD2
Elastic scattering MM6&7
Telescope 6&7 are analyzed for 12Be beam.
The energy of Si vs angle plot for each telescope
(CsI veto and beam position gate) are shown.
Fixed
e748
Sun Jul 9 18:44:38 2017
e748
BEAM
General
CD2
LOST BEAM around 18h30
Vaccuum was lost after CSS2, so we lost the
primary beam (18:30)
Operators called the astreinte.
Fixed
e748
Sun Jul 9 20:38:11 2017
e748
BEAM
General
CD2
LOST BEAM around 18h30
Seems there is a water leak in the beam line
near alpha.
Astreinte is at work.
Fixed
e748
Sun Jul 9 23:57:34 2017
e748
BEAM
General
CD2
NUMBER FOR PCP
There is a major shutdown of the GANIL phone
system.
You can not call the pcp via the usual extention;
Fixed
e748
Mon Jul 10 00:23:41 2017
e748
RUN
General
CD2
Return of the beam (Jedi not available)
Beam is back.
JCT refoc the beam on target (attached pictures).
All god beside that. Still no phone on campus!
Fixed
e748
Mon Jul 10 00:35:29 2017
e748
RUN
General
CD2
Run 380
Started at 0:02
18O 4.3 uAe, fluctuating
Fixed
e748
Mon Jul 10 01:34:12 2017
e748
RUN
General
CD2
Run 380 (file change)
Data file change at 1:18 -> run_0380.dat.10-07-17_00h02m00s.1
18O 4.5 uAe
Fixed
e748
Mon Jul 10 02:04:33 2017
e748
CATS
General
CD2
CATS raw strips and trajectories
Fixed
e748
Mon Jul 10 02:47:27 2017
e748
RUN
General
CD2
Run 380 (file change)
2:26 data file change -> run_0380.dat.10-07-17_00h02m00s.2
18O 4.5 uAe
Fixed
e748
Mon Jul 10 03:34:24 2017
e748
RUN
General
CD2
Run 380 (file change)
3:33 data file change -> run_0380.dat.10-07-17_00h02m00s.3
18O 4.5 uAe