MUST2 SAMURAI_2018 S3-LEB-LPC SUPERNEMO MUGAST EXPAND SCALP GALATRON HiCARI VELO
  MUST2, Page 13 of 48  Not logged in MUST2
Status ExpNbr Date Authordown Type Category Target-Source Subject
Fixede748 Mon Jul 3 03:48:57 2017 e748OFFLINEGeneral Correlation Test on Run 104

We analysed run 104 to check the correlation of events coded in different crates. It is clear now that the events from the MUST2 crate are shifted by +1 with respect to the CHIO crate.

On the following plot, parameters coded in the two different crates (MUST2 and CHIO) are displayed :
- (left) unshifted Vs unshifted:
chShifted.Draw("ADC_VOIE_29:ADC_CHIO_V15");
- (right) shifted(N+1) Vs unshifted(N):
chShifted.Draw("ADC_VOIE_29:AutoTree.ADC_CHIO_V15");

To check the correlation on a converted root run (here example for run 104), execute the macro:
> root
> .L CheckDataShift.C
> CheckDataShift(104)
Attachment 1: run_104_shifting.pdf
run_104_shifting.pdf
Fixede748 Mon Jul 3 06:26:24 2017 e748OTHERGeneralN/ADamned ELOG
We just recovered the ELOG after 5-6 hrs out of order
Fixede748 Mon Jul 3 06:30:54 2017 e748BEAMGeneralN/A12Be beam rate
Final 12Be beam rate as obtained by JCT with present wedge is about 6.10^3 per euA in D6
expected Imax of 18O is 6-7 euA

purity is 99%
Fixede748 Mon Jul 3 06:30:58 2017 e748DAQSoftware PROBLEM of conversion for RUN with even number
IMPORTANT

We realized that starting at run 160 (included) all run with an even number (160,162,etc) give an error at conversion:

--> Error : 8018c82 Error in getting infomation in your file!
May be no Ganil format run !
or your are not a the begining of a run (try a Skip('r') before))
code erreur sortie rd_evstr (en hexa) = 1101--> Error : 8018001 Initialization of event structure: Event Struct :size = 8192 Struc = 38891632


This has to be investigated by experts of the DAQ when they will come...
Fixede748 Mon Jul 3 07:04:30 2017 e748OTHERGeneralN/Atritons
Count rate in ZD plastic is bout 2;5 times larger than in CATS1 and CATS2, probably due to tritons
Fixede748 Mon Jul 3 07:06:17 2017 e748RUNGeneralCD2RUN 173 - First Physics with 12Be
RUN 173

START: 6H11
STOP: 7H31

PRIMARY BEAM: 1.2 uA

TARGET: CD2 (2.5 mg.cm-2, to be checked)

TRIGGER: MUST2 1 to 8

BEAMRATE: 8 kHz on CATS2
22 kHz on PL
Attachment 1: run173_MUST2_Ecal.png
run173_MUST2_Ecal.png
Attachment 2: run173_MUST2_dEE.png
run173_MUST2_dEE.png
Attachment 3: Capture-1.png
Capture-1.png
Fixede748 Mon Jul 3 07:52:36 2017 e748RUNGeneralCD2RUN 175
RUN 175


START: 7h45
STOP:

PRIMARY BEAM: 1.2 uA

TARGET: CD2 (2.5 mg.cm-2, to be checked)

TRIGGER: MUST2 1 to 8

BEAMRATE: 9 kHz on CATS2
22 kHz on PL

(RUN 174 junk - skipped on purpose)
Fixede748 Mon Jul 3 07:52:39 2017 e748RUNGeneralCD2RUN 175
RUN 175


START: 7h45
STOP:

PRIMARY BEAM: 1.2 uA

TARGET: CD2 (2.5 mg.cm-2, to be checked)

TRIGGER: MUST2 1 to 8

BEAMRATE: 9 kHz on CATS2
22 kHz on PL

(RUN 174 junk - skipped on purpose)
Fixede748 Mon Jul 3 17:31:08 2017 e748OFFLINEGeneralCD2BEAM and FRAGMENT PID
We used the Si in D6 and the TOF(CATS1-CAVIAR) to identify the beam nuclei.

Using a gate on 12Be and 11Be, we looked at the PID using Qplastic VS TOF(CATS1-CAV) and TOF(CATS1-PL).

It seems that we can separate 12Be and 11Be using these two spectras.
Attachment 1: run_203_PID_SiD6.pdf
run_203_PID_SiD6.pdf
Attachment 2: run_203_PID_beam.pdf
run_203_PID_beam.pdf
Attachment 3: run_203_PID_reactionfrag.pdf
run_203_PID_reactionfrag.pdf
Fixede748 Mon Jul 3 20:02:46 2017 e748OFFLINEGeneralCD2run217
PID run 217
trigger = plast
Attachment 1: Capture.png
Capture.png
Fixede748 Mon Jul 3 21:13:18 2017 e748OFFLINEGeneralN/Acats
run222 cats
Attachment 1: Capture.png
Capture.png
Fixed  Mon Jul 3 22:40:33 2017 e748RUNGeneral Plastic_Cats_T
Tac run_223

Range: T_CATS1_CAV 1 µs
T_CATS1_2 200ns
T_MUVI_CATS1 500ns
T_PL_CATS1 1µs
T_PLch_CATS1 1µs
T_PL_CATS2 1µs
T_Pl_CHIO 2µs

Attachment 1: run_223_tac2.pdf
run_223_tac2.pdf
Attachment 2: run_223_tac1.pdf
run_223_tac1.pdf
Fixede748 Tue Jul 4 01:21:04 2017 e748OFFLINEGeneralCD2run 236
cats > target
cats > target, gated by must
Attachment 1: Capture.png
Capture.png
Fixede748 Tue Jul 4 04:01:50 2017 e748RUNHardware RUN249
RUN249

Same setting as RUN248.
run_0249.dat.04-07-17_03h56m24s
Start 3h56 Gtape OK
Stop 4h58
608 MB
Fixede748 Tue Jul 4 05:08:30 2017 e748MUST2Hardware MUST2 signql check in offline analysis
RUN248
MUST2 DSSD XE signal for all telescopes T1-T8 confirmed.
MUST2 DSSD YE signal for all telescopes T1-T8 confirmed.
MUST2 DSSD XT signal for all telescopes T1-T6,T8 confirmed. No T7.
MUST2 DSSD XT signal for all telescopes T1-T4,T6,T8 confirmed. No T5,7.

MUST2 Csi E signal for all telescopes T1-T4,T6,T7 confirmed.
MUST2 Csi t signal for no telescopes T1-T8. This is normal.

MUST2 SiLi E signal for all telescopes T5,T8 confirmed.
MUST2 SiLi T signal for all telescopes T5,T8 confirmed.
Fixede748 Tue Jul 4 05:11:20 2017 e748MUST2Hardware MUST2 signql check in offline analysis
RUN248
MUST2 DSSD XE signal for all telescopes T1-T8 confirmed.
MUST2 DSSD YE signal for all telescopes T1-T8 confirmed.
MUST2 DSSD XT signal for all telescopes T1-T6,T8 confirmed. No T7.
MUST2 DSSD XT signal for all telescopes T1-T4,T6,T8 confirmed. No T5,7.

MUST2 Csi E signal for all telescopes T1-T4,T6,T7 confirmed.
MUST2 Csi t signal for no telescopes T1-T8. This is normal.

MUST2 SiLi E signal for all telescopes T5,T8 confirmed.
MUST2 SiLi T signal for all telescopes T5,T8 confirmed.
Attachment 1: 2017-07-04_run248_gatconf.png
2017-07-04_run248_gatconf.png
Attachment 2: 2017-07-04_run248_must2_energy_x.png
2017-07-04_run248_must2_energy_x.png
Attachment 3: run248_MUST2_xt.png
run248_MUST2_xt.png
Attachment 4: run248_MUST2_yt.png
run248_MUST2_yt.png
Attachment 5: run248_MUST2_CsIE.png
run248_MUST2_CsIE.png
Attachment 6: run248_MUST2_CsIT.png
run248_MUST2_CsIT.png
Attachment 7: run248_MUST2_SiLiE.png
run248_MUST2_SiLiE.png
Attachment 8: run248_MUST2_SiLiT.png
run248_MUST2_SiLiT.png
Attachment 9: run248_MUST2_MM1_SiEvsCsIE.png
run248_MUST2_MM1_SiEvsCsIE.png
Attachment 10: run248_MUST2_DSSDYE.png
run248_MUST2_DSSDYE.png
Fixede748 Tue Jul 4 05:20:31 2017 e748RUNHardware RUN250
Same setting as RUN248.
run_0250.dat.04-07-17_04h58m50s
start 4h58 Gtape ok
Stop. The HT for SiLi T5 1 tripped off with the over current alert (current limit set 25 micro A for 400 V). Turned on the HT and restarted the run. The current was slowly increasing over time. Watch out the current read.
Fixede748 Tue Jul 4 05:23:20 2017 e748CATSSoftware CATS signal
RUN248
The chqrge distribution of CATS1&2, X&Y
Gate:CATSdiv trigger
Attachment 1: run248_CATS1XQ.png
run248_CATS1XQ.png
Attachment 2: run248_CATS1YQ.png
run248_CATS1YQ.png
Attachment 3: run248_CAT2XQ.png
run248_CAT2XQ.png
Attachment 4: run248_CATS2YQ.png
run248_CATS2YQ.png
Fixede748 Tue Jul 4 07:00:55 2017 e748RUNHardware RUN252
Same setting as RUN248.
RUN251 junk header
run_0252.dat.04-07-17_05h33m06s
Start 5h33 end 6h30.
No issue during the run.
Fixede748 Tue Jul 4 07:01:50 2017 e748RUNHardware RUN254
Same setting as RUN248.
RUN253 junk header
run_0254.dat.04-07-17_06h32m10s
Start 6h32 - 7h33 no issue

ELOG Home Page