MUST2 SAMURAI_2018 S3-LEB-LPC SUPERNEMO MUGAST EXPAND SCALP GALATRON HiCARI VELO
  MUST2, Page 11 of 48  Not logged in MUST2
New entries since:Thu Jan 1 01:00:00 1970
Fixed, e748, Wed Jul 5 14:34:15 2017, Marlene, RUN, General, CD2, Run summary 329,330 Scalers_run330.pngTAC_run330.pngcorr_run330.pngexl_run330.pngCapture-1.png
We thought the merge was broken, but the issue was the Raw Data gruscipt connecting to the wrong port.

Everything reestablished as before.
Fixed, e748, Wed Jul 5 15:30:03 2017, Freddy, OFFLINE, General, , MUST2 offline analysis of run 323 PID_M2_run332.png
Here is a plot of the MUST2 PID for telescope 3:
- dE - TOF with a veto on CsI_ to remove direct 12Be hitting the detector.
- dE - E ungated for a given crystal close to the beam axis
Fixed, e748, Wed Jul 5 17:15:57 2017, e748 DB, RUN, General, CD2, screenshot of scalers  Capture-run330.png
primary I = 6.9 uA

[IMG]elog:209/1[/IMG]
Fixed, e748, Wed Jul 5 18:36:49 2017, Freddy, OFFLINE, General, , PID from NUMEXO merged (partially) DeE_CHIO_NUMEXO_run323.png
Here is the PID(dE Vs E)  plot obained using the IC energy from NUMEXO Vs the plastic energy coded in our acquisition for the long run of last night (323)

The resolution is indeed about 10% (estimated on the 12Be spot.
Fixed, e748, Wed Jul 5 18:47:25 2017, e748 DB, RUN, General, CD2, new run - 331 Capture-run331.png
primary I = 6.9 uA

[IMG]elog:211/1[/IMG]
Fixed, e748, Wed Jul 5 19:05:13 2017, e748 DB & IS, RUN, General, CD2, tritons in the beam Capture-tritons.png
Tritons can be seen from the following plot. Some of them cross target frame and then lose 1.5MeV in the DSSDs. 
12Be particles are stopped by the frame. 
Fixed, e748, Wed Jul 5 19:10:33 2017, e748 DB&IS, ONLINE, General, CD2, tritons in the beam Capture-tritons.png
Tritons can be seen from the following plot. Some of them cross target frame and then lose 1.5MeV in the DSSDs. 
12Be particles are stopped by the frame. 
Fixed, e748, Wed Jul 5 21:13:14 2017, e748 IS, RUN, General, CD2, RUN 331 scalers  
primary beam I = 6.5 uA unstable in the last 30 minutes (20h20 - 20h45)

[IMG]elog:209/1[/IMG]
Fixed, e748, Wed Jul 5 22:29:10 2017, e748 DB, ONLINE, General, CD2, trajectories Capture-traj.png
[IMG]elog:215/1[/IMG]
Fixed, e748, Thu Jul 6 00:07:33 2017, e748 DB, ONLINE, General, CD2, Strips CATS raw  Cats-raw-run331.png
[IMG]elog:216/1[/IMG]
Fixed, e748, Thu Jul 6 01:00:21 2017, Freddy, MUST2, Hardware, N/A, Problem with position of télescopes 6&7 Nouveau_document_2017-07-06.pdf
Due to a cabling problem telescope 6 was seen as telescope 7 and inversly.
Fixed, e748, Thu Jul 6 01:26:15 2017, Franck et Valérian, CHIO, Hardware, N/A, UPDATE : CHIO's electronic scheme (valid from run 293) Schema_electronique_CHIO.pdf
Since Run 293 inspection line of NUMEXO 2 has been used as input signal of CAEN digitizer.
Fixed, e748, Thu Jul 6 01:34:42 2017, e748, RUN, General, CD2, Run 331 (file change) Scalers_run331_2.png
1:25 file change -> run_0331.dat.05-07-17_18h45m44s.2
18O beam: 6.6 uAe
CATS1: 40000 cps
Fixed, , Thu Jul 6 02:02:48 2017, Anastasia, OFFLINE, General, , First signs of the elastic Elastic.png
Hereby you can see some first signs of the [U]elastic scattering[/U] [COLOR=purple]12Be(d,d)12Be[/COLOR]
with punch through events that will be later taken care of, after the calibration of[COLOR=blue] CsI[/COLOR].
Pinned, e748, Thu Jul 6 02:41:13 2017, Freddy and the night shifters, CHIO, General, , CHIO analog treatment 
Interestingly, the bipolar output of the amplifier of the CHIO sent (and splitted) to check correlation on the channel 15 of the ADC CHIO (or on channel
29 of the ADC MUST2) provides a much better resolution (about 10%) than the one obtained using the unipolar output that we were looking since then (about
20% resolution).
Fixed, e748, Thu Jul 6 03:03:39 2017, iFreddy and the night shifters, CHIO, General, , CHIO analog (unipolar and bipolar) and digital run323_chiocompare.pngDeE_CHIO_NUMEXO_run323.pngrun323_CHIO_DIGIVAEN.pdf
Interestingly, the bipolar output of the amplifier of the CHIO sent (and splitted) to check correlation on the channel 15 of the ADC CHIO (or on channel
29 of the ADC MUST2) provides a much better resolution (about 10%) than the one obtained using the unipolar output that we were looking since then (about
20% resolution).
Fixed, e748, Thu Jul 6 03:35:32 2017, e748, RUN, General, CD2, Run 331 (file change) Scalers_run331_3.png
3:30 file change -> run_0331.dat.05-07-17_18h45m44s.3
18O: 7.2 uAe
CATS1: 40000 cps
Fixed, e748, Thu Jul 6 05:48:26 2017, e748, MUST2, General, CD2, SiLi 1/T5 trip 
Restart SiLi 1/T5 that reached 26 uA and tripped a few minutes ago.
Current = 21 uA when biased up again, and reaches 24 uA in a few minutes.
Fixed, e748, Thu Jul 6 06:23:18 2017, e748, RUN, General, CD2, Run 331 (file change) scalers_run331_4.png
6:19 file change -> run_0331.dat.05-07-17_18h45m44s.4
18O 7.1 uAe
CATS1 : 36000 cps
Fixed, e748, Thu Jul 6 07:17:05 2017, e748, MUST2, General, CD2, SiLi 1/T5 trip 
SiLi 1/T5 tripped at 7:16.
We turn it on again immediately -> 23 uA

ELOG Home Page