MUST2 SAMURAI_2018 S3-LEB-LPC SUPERNEMO MUGAST EXPAND SCALP GALATRON HiCARI VELO
  MUGAST, Page 8 of 132  Not logged in MUGAST
Fixed, com2019, Sat Apr 6 06:24:04 2019, mugast, RUN, Software, CD2, new data 5more statistics° Run_256_kin.png
 
Fixed, e768s, Wed Jul 17 01:08:03 2019, mugast, VAMOS, General, LiF, new beam settings run_60_target_thick_01_Vamos.png
The last values Q32=21.0, Q31=22.8
With these new optimzed values, we have: 
Std dev-x=6.147
Fixed, e744s, Sat Apr 13 17:31:54 2019, mugast, VAMOS, Hardware, , new Threshold on DC1 Channel 127 
Channel 127 of DC1 had a reduction of gain from yesterday, I corrected the gain by calibration and I reduced the threshold from 2114 to 2083 in order to
reach the same low level.
(We can still see the lower gain in the online because the watcher is not reloaded, but it is ok in the root files) 
Fixed, e744s, Mon Apr 15 15:36:48 2019, iulian Francois Fairouz Catalin, OFFLINE, General, CH2, looking for gamma proton events elab_Brho_gamma_thetaCond_int_ThinTar.pdfelab_Brho_gamma_thetaCond_int_ThickTar.pdfelab_Etot_gamma_thetaCond_ThinTar.pdfelab_Etot_gamma_thetaCond_ThickTar.pdf1504b.jpg
elab_Brho_gamma_thetaCond_int_ThinTar.pdf   -> thin target ELab protons vs Brho 14O in M/Q for protons mult 1 in MUGAST. Orange are the same, but conditioned
by Theta Lab protons vs Brho Vamos.
elab_Brho_gamma_thetaCond_int_ThickTar.pdf  -> thick target ELab protons vs Brho 14O in M/Q for protons mult 1 in MUGAST. Orange are the same, but conditioned
Fixed, e744s, Fri Apr 12 13:53:56 2019, diego, OTHER, General, , intervention 
TAC FPMW_HF in VAMOS was still out of range for MUGAST physics
We increased the range from 1us to 2us and applied a delay of 200 ns to the stop of the TAC.
Fixed, TEST, Mon Feb 24 10:26:29 2020, Marlène, GRIT, General, , infos 
We have changed the range of the TAC FAG-HF to 500ns (it was 200 ns before)

there is no delay on the STOP of MUVI, it is directly the HF clean.
Fixed, e768s, Fri Jul 19 13:24:01 2019, mugast, OFFLINE, General, LiF, g-ray spectrum (run 112) requiring 19Ne in VAMOS 21.png
 
Fixed, e744s, Sat Apr 13 17:03:14 2019, Jérémie & François, OFFLINE, General, , first gamma spectrum 35gamma.png
After a few hours run.
Fixed, e744s, Sun Apr 14 03:30:28 2019, Iulian Iulia, OFFLINE, Social, CH2, first calculation ECM ThetaCM for gamma-P emission first_gammaP_rec.pdfAlias_iul.C
 
Fixed, e768s, Sat Jul 27 11:02:13 2019, mugast, ONLINE, General, , figures run 152 18x
 
Fixed, e744s, Tue Apr 16 00:04:08 2019, beyhan, OFFLINE, General, , ewire evolution vs beam intensity (normalized to CATS intensity) EWIRE0_change_122_vs_130_vs_131.pdfEWIRE1_change_122_vs_130_vs_131.pdfEWIRE2_change_122_vs_130_vs_131.pdfEWIRE3_change_122_vs_130_vs_131.pdf
 
Fixed, , Mon Apr 8 07:54:53 2019, iulian, MUST2, Hardware, , end alpha contamination run bilan_run262_bck_mugast4.pngbilan_run262_bck_mugast3.pngbilan_run262_bck_mugast2.pngbilan_run262_bck_mugast1.png
Problem M3 EY , moving piedestal... See below
Alfa spectra have changed, no longer continuous excepting partially MM2.
Fixed, e793s, Fri Mar 12 03:57:46 2021, Taras, Nishu, Chloe, Charlie, VAMOS, General, CD2, dipole issue fixed run56_dipolefixed.png
the alimentation on dipole (G1.G.D4.P) was turned off,
the value was resetted(322.6) and works fine now.
cour: 323.5 A
Fixed, e744s, Tue Apr 16 01:01:42 2019, beyhan, louis, serge, , OFFLINE, General, , different parameters evolution as function of intensity 6x
 
Fixed, e768s, Sat Jul 27 21:12:47 2019, teodora & beyhan, OTHER, Hardware, , cout rate with no beam & water level check 6x
Around 9 pm, we observed an average count rate of 30kHz on the "or agata" scaler rates panel of GECO. The other count rates were ok.
In the agata acquisition monitoring the rate was given about 8k. one of the detector was showing a rate in red.
Fixed, e793s, Tue Mar 16 04:06:46 2021, Lynda, Cyril, Nishu, AGATA, General, CD2, counting rates AGATA 
crystal 12B counting rate is too low ~ 5 / s compared to an average of ~ 80/s - 100/ s for the other crystals
and 05B counting rate is too high from time to time reaching ~2000/s
but every thing is "green" ?!
Fixed, com2019, Sat Apr 6 13:10:11 2019, mugast, VAMOS, Hardware, CD2, check in VAMOS HV 
target drift chamber HV checked. They are OK
Fixed, e744s, Thu Apr 11 17:37:29 2019, Valérian, Chloé and François, OTHER, Hardware, , changes in the electronic 
Changes made in the electronic during the break between 14N and 14O

1) T_VAMOS-CATS1
    Fixed, e744s, Thu Apr 11 18:08:12 2019, Marlène, OTHER, Hardware, , changes in the electronic 
[quote="Valérian, Chloé and François"]Changes made in the electronic during the break between 14N and 14O

1) T_VAMOS-CATS1
Fixed, e744s, Mon Apr 15 09:59:32 2019, Marlène, RUN, General, CH2, change thresholds in DSSD MUST2 and suppression CsI 
From RUN126
change of MUST2 DSSD thresholds : thresholds are 583 keV now
change of CsI suppression : before it was suppressed up to 8210 now it is 8200 

ELOG Home Page