Fixed, e768s, Mon Jul 22 06:14:38 2019, Faïrouz & Sylvain, RUN, General, LiF, Run 122 with more centered beam profile 
|
Even with a more centered beam profile, AGATA request triggers is increasing too much and too fast!!! after 5 mn run, we are already at 100khz!!!
Need Bertrand to solve the situation. |
Fixed, e768s, Mon Jul 22 06:32:40 2019, Faïrouz & Sylvain, RUN, General, LiF, We put the Faraday cup because AGATA can not cope with the very high counting rate (>110kHz)
|
We will call Emmanuel & Bertrand.
We stopped the run 122, waiting for Bertrand to come and work on the beam size and focalization. |
Fixed, e768s, Mon Jul 22 07:48:03 2019, OttoRun, RUN, General, LiF, Run123
|
*************************
Run : 123
*************************
Start at 2019-07-22 07:47:55.021346
beam intensity after optimization 2.0e7 pps
OR VAMOS ~ 1500 Hz
Target: 1.25 mg/cm2 (nb 1) 7LiF
Triggers
MUGAST (backward, MM, 90 deg)
VAMOS %100
BaF2 %100
Stop at 2019-07-22 08:16:58.580316
Stop comment: End of beam position optimization |
Fixed, e768s, Mon Jul 22 08:23:02 2019, Christian - Bertrand, Sylvain, Frank, Francois, BEAM, General, LiF, Beam adjustment notes
|
Adjustment of beam position, moved up by approximately 15mm on VAMOS FP, down by 2mm on target. AGATA rate reduced to normal, about 4k after 5 min equilibration, no substantial satellite seen in direct beam on VAMOS FP. See separate entry for detailed discussion. Note, however that while beam intensity measurement is 2.1e7, VAMOS trigger on reaction setting is approximately 1100. |
Fixed, e768s, Mon Jul 22 08:26:07 2019, OttoRun, RUN, General, LiF, Run124
|
*************************
Run : 124
*************************
Start at 2019-07-22 08:18:38.043920
Restart after beam position optimization by Bertrand to reduce AGATA rate
(probably from beam hitting the target frame)
Beam position in VAMOS FP moved by +15 mm in vertical
-> - 2 mm in vertical on target
Beam intensity: 2.0e7 pps
OR VAMOS ~ 1100 Hz
So the VAMOS/intensity ratio has changed
Target: 1.25 mg/cm2 (nb 1) 7LiF
Triggers:
MUGAST (backward, MM, 90 deg)
VAMOS %100
BaF2 %100
Rates:
FAG: 160
MUGAST: 150
OR AGATA: 1400
OR VAMOS: 1100
Stop at 2019-07-22 10:54:58.589478
Stop comment: stop to recover MG3X |
Fixed, e768s, Mon Jul 22 08:28:00 2019, mugast, OTHER, General, LiF, Scalers at start of run124
|
|
Fixed, e768s, Mon Jul 22 08:29:19 2019, Faïrouz, Sylvain, Francois et Franck, Bertrand, BEAM, General, LiF, Beam profile updated 
|
To solve the very high counting rate observed on AGATA (and on MUST2 with a lesser degree), the beam was retuned.
After inspection of the beam profile in VAMOS, Bertrand tuned the vertical steerers G1.DC21-VE (from 0.5 -> 0.0A). The consequence is a shift of 2mm in vertical position at the target position.
Everything seems back to normal. |
Fixed, e768s, Mon Jul 22 09:40:06 2019, Franck, François, Adrien, Jérémy, Nicolas, ONLINE, General, LiF, Screenshots run 124 22x
|
|
Fixed, e768s, Mon Jul 22 10:01:12 2019, Franck, François D, BEAM, General, LiF, Beam profile
|
Slight shift in vertical +1 mm (with respect to this morning at 8:30)?
Intensity = 1.7e7 pps |
Fixed, e768s, Mon Jul 22 11:16:09 2019, OttoRun, RUN, General, LiF, Run125
|
*************************
Run : 125
*************************
Start at 2019-07-22 11:11:08.167773
Beam intensity: 2.0e7 pps
OR VAMOS ~ 1100 Hz
So the VAMOS/intensity ratio has changed
Target: 1.25 mg/cm2 (nb 1) 7LiF
Triggers:
MUGAST (backward, MM, 90 deg)
VAMOS %100
BaF2 %100
Rates:
FAG: 160
MUGAST: 150
OR AGATA: 1400
OR VAMOS: 1100
MG3 pedestal suppression between 0 and 6800
Stop at 2019-07-22 15:16:35.174290
Stop comment: Stop to check beam intensity with vamos |
Fixed, e768s, Mon Jul 22 11:21:25 2019, mugast, MUST2, Software, , Pedestals of MG3 
|
Pedestals of MG3_X have changed yesterday, they are back to about 8200 as they should be --> saved in ped_muvi2sec2_22072019_new
We are using wrong pedestals (of about 9600) --> the pedestals are saved under mugast account as ped_muvi2_sec2_22072019_sameas_1807219
We kept the same pedestals but we reduced the pedestal suppression to 0 - 6800 in order not to suppress the data of one other 2 mates.
The attached spectrum shows that all the X of MG3 are recovered (although the impact matrix still does not work) |
Fixed, e768s, Mon Jul 22 11:42:22 2019, Marlène, François D, Franck, BEAM, General, LiF, Beam profile and intensity
|
Intensity = 1.8e7 pps
Slight shifts in x and y compared to this morning 8:30
x : -1.1 mm
y : +1.7 mm |
Fixed, , Mon Jul 22 12:33:17 2019, Kseniia, AGATA, General, , Stats on 19Ne  
|
Full stats for runs 112..124 with the event-by-event Doppler correction. So, we see 4140 kev.
Also, the betas of all the 19Ne with Q= 9,10 identified in VAMOS |
Fixed, , Mon Jul 22 12:54:25 2019, Kseniia, AGATA, General, , Beta vs gamma-ray energy in 19Ne, runs 112-124
|
|
Fixed, e768s, Mon Jul 22 13:40:41 2019, Franck, ONLINE, General, LiF, Run 125 screenshots 22x
|
|
Fixed, e768s, Mon Jul 22 14:45:34 2019, François D, Franck, BEAM, General, LiF, Beam profile
|
Intensity = 1.3e7 pps
Beam position shift compared to this morning 8:30
x: -1.8 mm
y: +3.3 mm |
Fixed, TEST, Mon Jul 22 15:02:45 2019, OttoH.V., OTHER, Hardware, N/A, HVM_SUMMARY
|
*** hvm watcher summary ***
+10v/mg Slot: 5 (A1516B) Channel:5 Vmon: 10 V Imon: 0.407 A Status: On
+10v/t14mg Slot: 2 (A1516 ) Channel:5 Vmon: 9.99 V Imon: 0.577 A Status: On
+2.5V/MG10 Slot: 1 (A1518B) Channel:2 Vmon: 2.5 V Imon: 1.167 A Status: On
+2.5v/MG9 Slot: 1 (A1518B) Channel:1 Vmon: 2.49 V Imon: 1.196 A Status: On
+2.5v/mg1 Slot: 4 (A1518B) Channel:2 Vmon: 2.5 V Imon: 1.263 A Status: On
+2.5v/mg11 Slot: 3 (A1518B) Channel:2 Vmon: 2.49 V Imon: 1.199 A Status: On
+2.5v/mg3 Slot: 3 (A1518B) Channel:0 Vmon: 2.49 V Imon: 1.254 A Status: On
+2.5v/mg4 Slot: 4 (A1518B) Channel:1 Vmon: 2.49 V Imon: 1.246 A Status: On
+2.5v/mg5 Slot: 3 (A1518B) Channel:1 Vmon: 2.49 V Imon: 1.252 A Status: On
+2.5v/mg7 Slot: 4 (A1518B) Channel:0 Vmon: 2.49 V Imon: 1.256 A Status: On
+2.5v/t1 Slot: 0 (A1518B) Channel:0 Vmon: 2.49 V Imon: 1.21 A Status: On
+2.5v/t2 Slot: 0 (A1518B) Channel:1 Vmon: 2.49 V Imon: 1.205 A Status: On
+2.5v/t3 Slot: 0 (A1518B) Channel:2 Vmon: 2.49 V Imon: 1.195 A Status: On
+2.5v/t4 Slot: 1 (A1518B) Channel:0 Vmon: 2.49 V Imon: 1.214 A Status: On
+3.3v/mg Slot: 5 (A1516B) Channel:2 Vmon: 3.29 V Imon: 0.989 A Status: On
+3.3v/t14mg Slot: 2 (A1516 ) Channel:2 Vmon: 3.3 V Imon: 0.976 A Status: On
+5v/mg3511 Slot: 5 (A1516B) Channel:3 Vmon: 5 V Imon: 0.57 A Status: On
+5v/mg741 Slot: 5 (A1516B) Channel:4 Vmon: 5 V Imon: 0.555 A Status: On
+5v/t123 Slot: 2 (A1516 ) Channel:3 Vmon: 5.04 V Imon: 0.629 A Status: On
+5v/t4mg Slot: 2 (A1516 ) Channel:4 Vmon: 4.97 V Imon: 0.629 A Status: On
-2.5V/MG10 Slot: 1 (A1518B) Channel:5 Vmon: 2.49 V Imon: 1.774 A Status: On
-2.5V/MG9 Slot: 1 (A1518B) Channel:4 Vmon: 2.5 V Imon: 1.79 A Status: On
-2.5v/mg1 Slot: 4 (A1518B) Channel:5 Vmon: 2.49 V Imon: 1.801 A Status: On
-2.5v/mg11 Slot: 3 (A1518B) Channel:5 Vmon: 2.48 V Imon: 1.788 A Status: On
-2.5v/mg3 Slot: 3 (A1518B) Channel:3 Vmon: 2.5 V Imon: 1.806 A Status: On
-2.5v/mg4 Slot: 4 (A1518B) Channel:4 Vmon: 2.5 V Imon: 1.796 A Status: On
-2.5v/mg5 Slot: 3 (A1518B) Channel:4 Vmon: 2.5 V Imon: 1.813 A Status: On
-2.5v/mg7 Slot: 4 (A1518B) Channel:3 Vmon: 2.5 V Imon: 1.8 A Status: On
-2.5v/t1 Slot: 0 (A1518B) Channel:3 Vmon: 2.49 V Imon: 1.79 A Status: On
-2.5v/t2 Slot: 0 (A1518B) Channel:4 Vmon: 2.49 V Imon: 1.808 A Status: On
-2.5v/t3 Slot: 0 (A1518B) Channel:5 Vmon: 2.49 V Imon: 1.806 A Status: On
-2.5v/t4 Slot: 1 (A1518B) Channel:3 Vmon: 2.51 V Imon: 1.832 A Status: On
-5v/mg3511 Slot: 5 (A1516B) Channel:0 Vmon: 4.99 V Imon: 0.361 A Status: On
-5v/mg741 Slot: 5 (A1516B) Channel:1 Vmon: 5 V Imon: 0.344 A Status: On
-5v/t123 Slot: 2 (A1516 ) Channel:0 Vmon: 5.02 V Imon: 0.418 A Status: On
-5v/t4mg Slot: 2 (A1516 ) Channel:1 Vmon: 4.99 V Imon: 0.392 A Status: On
CsI/t1 Slot: 12 (A1837 ) Channel:0 Vmon: 49.98 V Imon: 0 uA Status: On
CsI/t2 Slot: 12 (A1837 ) Channel:2 Vmon: 49.98 V Imon: 0 uA Status: On
CsI/t3 Slot: 12 (A1837 ) Channel:4 Vmon: 50 V Imon: 0 uA Status: On
CsI/t4 Slot: 12 (A1837 ) Channel:6 Vmon: 49.98 V Imon: 0 uA Status: On
CsI/t5 Slot: 13 (A1837 ) Channel:0 Vmon: 0 V Imon: 0 uA Status: Off
CsI/t6 Slot: 13 (A1837 ) Channel:2 Vmon: 0 V Imon: 0 uA Status: Off
CsI/t7 Slot: 13 (A1837 ) Channel:4 Vmon: 0 V Imon: 0 uA Status: Off
CsI/t8 Slot: 13 (A1837 ) Channel:6 Vmon: 0 V Imon: 0 uA Status: Off
DSSD/t1 Slot: 12 (A1837 ) Channel:1 Vmon: 70 V Imon: 0.7 uA Status: On
DSSD/t2 Slot: 12 (A1837 ) Channel:3 Vmon: 69.98 V Imon: 0.7 uA Status: On
DSSD/t3 Slot: 12 (A1837 ) Channel:5 Vmon: 70 V Imon: 2.92 uA Status: On
DSSD/t4 Slot: 12 (A1837 ) Channel:7 Vmon: 69.56 V Imon: 0.54 uA Status: On
MG10C Slot: 12 (A1837 ) Channel:11 Vmon: 0 V Imon: 0 uA Status: Off
MG11A Slot: 13 (A1837 ) Channel:5 Vmon: 59.86 V Imon: 0.2 uA Status: On
MG1T Slot: 13 (A1837 ) Channel:11 Vmon: 139.78 V Imon: 0.8 uA Status: On
MG3T Slot: 13 (A1837 ) Channel:1 Vmon: 159.88 V Imon: 0.4 uA Status: On
MG4T Slot: 13 (A1837 ) Channel:9 Vmon: 95.04 V Imon: 0.9 uA Status: On
MG5T Slot: 13 (A1837 ) Channel:3 Vmon: 149.84 V Imon: 1 uA Status: On
MG7T Slot: 13 (A1837 ) Channel:7 Vmon: 119.9 V Imon: 1.2 uA Status: On
MG9C Slot: 12 (A1837 ) Channel:9 Vmon: 189.74 V Imon: 0.42 uA Status: On
spare1 Slot: 12 (A1837 ) Channel:8 Vmon: 0 V Imon: 0 uA Status: Off
spare2 Slot: 12 (A1837 ) Channel:10 Vmon: 0 V Imon: 0 uA Status: Off
spare3 Slot: 13 (A1837 ) Channel:8 Vmon: 0 V Imon: 0 uA Status: Off
spare4 Slot: 13 (A1837 ) Channel:10 Vmon: 0 V Imon: 0 uA Status: Off
|
Fixed, TEST, Mon Jul 22 15:02:46 2019, OttoH.V., OTHER, Hardware, N/A, HVM_SUMMARY
|
*** hvm watcher summary ***
Slot: 8 (A1821H) Channel:1 Vmon: 0 V Imon: 0.001 uA Status: Off
CHANNEL00 Slot: 9 (A1821H) Channel:0 Vmon: 0 V Imon: 0 uA Status: Off
CHANNEL01 Slot: 9 (A1821H) Channel:1 Vmon: 0 V Imon: 0.001 uA Status: Off
CHANNEL02 Slot: 9 (A1821H) Channel:2 Vmon: 0 V Imon: 0.001 uA Status: Off
CHANNEL03 Slot: 9 (A1821H) Channel:3 Vmon: 0 V Imon: 0 uA Status: Off
CHANNEL04 Slot: 9 (A1821H) Channel:4 Vmon: 0 V Imon: 0.001 uA Status: Off
CHANNEL05 Slot: 9 (A1821H) Channel:5 Vmon: 0 V Imon: 0 uA Status: Off
CHANNEL06 Slot: 9 (A1821H) Channel:6 Vmon: 0 V Imon: 0 uA Status: Off
CHANNEL07 Slot: 9 (A1821H) Channel:7 Vmon: 0 V Imon: 0 uA Status: Off
CHANNEL08 Slot: 9 (A1821H) Channel:8 Vmon: 0 V Imon: 0 uA Status: Off
CHANNEL09 Slot: 9 (A1821H) Channel:9 Vmon: 0 V Imon: 0.001 uA Status: Off
CHANNEL10 Slot: 9 (A1821H) Channel:10 Vmon: 0 V Imon: 0 uA Status: Off
CHANNEL11 Slot: 9 (A1821H) Channel:11 Vmon: 0 V Imon: 0.001 uA Status: Off
FP_CATS0 Slot: 2 (A1821HMP) Channel:6 Vmon: 529.5 V Imon: 0.005 uA Status: On
FP_CATS1 Slot: 2 (A1821HMP) Channel:7 Vmon: 529.25 V Imon: 0 uA Status: On
FP_CATS2 Slot: 2 (A1821HMP) Channel:8 Vmon: 529.5 V Imon: 0.001 uA Status: On
FP_CATS3 Slot: 2 (A1821HMP) Channel:9 Vmon: 529.25 V Imon: 0.001 uA Status: On
FP_CATS4 Slot: 2 (A1821HMP) Channel:10 Vmon: 529 V Imon: 0.08 uA Status: On
FP_CATS5 Slot: 2 (A1821HMP) Channel:11 Vmon: 528.5 V Imon: 0.04 uA Status: On
FP_DC1_cat Slot: 3 (A1821HM) Channel:0 Vmon: 499.75 V Imon: 30.36 uA Status: On
FP_DC2_cat Slot: 3 (A1821HM) Channel:1 Vmon: 499.5 V Imon: 30.32 uA Status: On
FP_DC_Wi1 Slot: 6 (A1821H) Channel:0 Vmon: 650 V Imon: 0 uA Status: On
FP_DC_Wi2 Slot: 6 (A1821H) Channel:1 Vmon: 650 V Imon: 0 uA Status: On
FP_DC_Wi3 Slot: 6 (A1821H) Channel:2 Vmon: 649.75 V Imon: 0.002 uA Status: On
FP_DC_Wi4 Slot: 6 (A1821H) Channel:3 Vmon: 650 V Imon: 0.001 uA Status: On
FP_IC_Cath Slot: 10 (AG5262) Channel:0 Vmon: 992 V Imon: 19.76 uA Status: On
FP_IC_PAD Slot: 7 (A1821H) Channel:1 Vmon: 404.5 V Imon: 0 uA Status: On
FP_IC_Wi Slot: 7 (A1821H) Channel:0 Vmon: 134.5 V Imon: 0 uA Status: On
FP_IC_casq Slot: 10 (AG5262) Channel:1 Vmon: 994 V Imon: 0.02 uA Status: On
FP_diamond Slot: 8 (A1821H) Channel:0 Vmon: 399.75 V Imon: 0.019 uA Status: On
FP_mob_pla Slot: 5 (A18332) Channel:0 Vmon: 0 V Imon: 0.2 uA Status: Off
Si1 Slot: 8 (A1821H) Channel:5 Vmon: 0 V Imon: 0.001 uA Status: Off
Si2 Slot: 8 (A1821H) Channel:6 Vmon: 0 V Imon: 0 uA Status: Off
Si3 Slot: 8 (A1821H) Channel:7 Vmon: 0 V Imon: 0 uA Status: Off
Si4 Slot: 8 (A1821H) Channel:8 Vmon: 0 V Imon: 0 uA Status: Off
Si5 Slot: 8 (A1821H) Channel:9 Vmon: 0 V Imon: 0 uA Status: Off
Si6 Slot: 8 (A1821H) Channel:10 Vmon: 0 V Imon: 0.001 uA Status: Off
Si7 Slot: 8 (A1821H) Channel:11 Vmon: 0 V Imon: 0 uA Status: Off
TP_DC1 Slot: 3 (A1821HM) Channel:6 Vmon: 0.25 V Imon: 0.02 uA Status: Off
TP_DC2 Slot: 3 (A1821HM) Channel:7 Vmon: 0 V Imon: 0 uA Status: Off
x Slot: 7 (A1821H) Channel:11 Vmon: 0 V Imon: 0 uA Status: Off
|
Fixed, e768s, Mon Jul 22 15:27:35 2019, Freddy, Valerian, Adrien, OFFLINE, General, LiF, Ex-Egamma 
|
Ex Egamma for run 112 115 116 117 118 119 120 121. |
Fixed, e768s, Mon Jul 22 16:08:24 2019, OttoRun, RUN, General, LiF, Run126 
|
*************************
Run : 126
*************************
Start at 2019-07-22 16:07:13.184511
Beam intensity: 1.5e7 pps
OR VAMOS ~ 1100 Hz
after check of beam intensity on target (factor of 2 in transmission with target)
Target: 1.25 mg/cm2 (nb 1) 7LiF
Triggers:
MUGAST (backward, MM, 90 deg)
VAMOS %100
BaF2 %100
Rates:
FAG: 160
MUGAST: 150
OR AGATA: 1300
OR VAMOS: 1500
MG3 pedestal suppression between 0 and 6800 |
|