Status |
ExpNbr |
Date |
Author |
Type |
Category |
Target-Source |
Subject |
Fixed | e744s |
Fri Apr 12 21:43:16 2019 |
OttoRun | RUN | General | CH2 | Run114 |
*************************
Run : 114
*************************
Start at 2019-04-12 21:42:12.558669
Run Conditions:
- Operator: Louis,Antoine
- Trigger: MUGAST + Vamos %100
- No target
- Beam: 14O
- Intensity: variable
- Brho = 0.6912 Tm
- CATS2 in
Comment:
VAMOS is Open
Stop at 2019-04-12 22:04:01.062421
Stop comment: test run |
Fixed | e744s |
Fri Apr 12 22:00:42 2019 |
Diego | TARGET | General | | very different target thickness |
|
Fixed | e744s |
Fri Apr 12 22:16:33 2019 |
OttoRun | RUN | General | CH2 | Run115 |
*************************
Run : 115
*************************
Start at 2019-04-12 22:15:31.632167
Run Conditions:
- Operator: Louis,Antoine
- Trigger: MUGAST + Vamos %100
- Target #3
- Beam: 14O
- Intensity: variable
- Brho = 0.5473 Tm
- CATS2 in
Comment:
VAMOS is Open
Stop at 2019-04-12 22:25:11.807535
Stop comment: Stopin to change Brho |
Fixed | e744s |
Fri Apr 12 22:28:15 2019 |
OttoRun | RUN | General | CH2 | Run116 |
*************************
Run : 116
*************************
Start at 2019-04-12 22:27:56.420427
Run Conditions:
- Operator: Louis,Antoine
- Trigger: MUGAST + Vamos %100
- Target #3
- Beam: 14O
- Intensity: variable
- Brho = 0.5199 Tm
- CATS2 in
Comment:
VAMOS is Open
Stop at 2019-04-12 22:32:41.994133
Stop comment: |
Fixed | e744s |
Fri Apr 12 22:33:22 2019 |
OttoRun | RUN | General | CH2 | Run117 |
*************************
Run : 117
*************************
Start at 2019-04-12 22:32:45.436663
Run Conditions:
- Operator: Antoine
- Trigger: MUGAST + Vamos %100
- Target #3
- Beam: 14O
- Intensity: variable
- Brho = 0.5199 Tm
- CATS2 in
- Finger Plancement
Comment:
Moving The finger
VAMOS is Open
Stop at 2019-04-12 22:39:59.872754
Stop comment: finger position at +12 mm |
Fixed | e744s |
Fri Apr 12 22:40:26 2019 |
OttoRun | RUN | General | CH2 | Run118 |
*************************
Run : 118
*************************
Start at 2019-04-12 22:40:07.011114
Run Conditions:
- Operator: Antoine
- Trigger: MUGAST + Vamos %100
- Target #3
- Beam: 14O
- Intensity: variable
- Brho = 0.5199 Tm
- CATS2 in
- Finger at +12 mm
Comment:
Moving The finger
VAMOS is Open
Stop at 2019-04-12 23:02:06.020781
Stop comment: Stoping to change CATS (1->%30000) and VAMOS Div (100->1000) |
Fixed | e744s |
Fri Apr 12 23:17:13 2019 |
OttoRun | RUN | General | CH2 | Run119 |
*************************
Run : 119
*************************
Start at 2019-04-12 23:15:13.390175
Run Conditions:
- Operator: Antoine
- Trigger: MUGAST + Vamos %1000 + CATS %30000
- Target #3
- Beam: 14O
- Intensity: ~6e4
- Brho = 0.5199 Tm
- CATS2 in
- Finger at +12 mm
- WITH AGATA
Comment:
VAMOS is Open
AGATA Coupling
Stop at 2019-04-13 00:42:48.531750
Stop comment: beam down because of heating |
Fixed | e744s |
Sat Apr 13 00:32:09 2019 |
Faïrouz, Iulian, Antoine & co | BEAM | General | N/A | Tests to understand the broad width (120 mm!!!) of the beam size at the FP of VAMOS |
Test 1: 14O beam on CH2 target (number 2= 105 um) and CATS2 inside:
The beam size in the FP of VAMOS was found of about: 150 mm !!!
Test 2: 14O beam on target with hole (Diameter of the hole=7mm) and CATS2 out
The beam size in the FP of VAMOS was found of about: 3 mm (to be checked with the run 112)
Test3: 14O beam on target with hole (Diameter of the hole=7mm) and CATS2 in
The beam size in the FP of VAMOS was found of about: 20 mm (to be checked with the run 113)
Test4: 14O beam on empty target and CATS2 inside
The beam size in the FP of VAMOS was found of about: 30 mm (to be checked with the run 114)
==> The problem of huge broadening of the beam size in test 1 was not due to straggling in CATS2
Test 5: 14O beam on CH2 target (number 3= 90 um, the same target that was used with 14N beam) and CATS2 inside:
The beam size in the FP of VAMOS was found of about: ~ 30 mm (to be checked with the run 115)
Bingo 
===> Target CH2 number 2 (105 um) has big inhomogenity problems or heavy impurities??? |
Fixed | e744s |
Sat Apr 13 04:18:00 2019 |
OttoRun | RUN | General | CH2 | Run120 |
*************************
Run : 120
*************************
Start at 2019-04-13 04:16:55.016739
Run Conditions:
- Operator: Mariluz Nikola Nicolas
- Trigger: MUGAST + Vamos %1000 + CATS %30000
- Target #3
- Beam: 14O
- Intensity: ~2e4
- Brho = 0.5199 Tm
- CATS2 in
- Finger at +12 mm
- WITH AGATA
Comment:
VAMOS is Open
AGATA Coupling
Stop at 2019-04-13 05:59:11.698155
Stop comment: CATS Internal trip
Stop at 2019-04-13 06:20:42.444844
Stop comment: VAMOS cut off |
Fixed | e744s |
Sat Apr 13 04:35:43 2019 |
Mariluz Nikola Nicolas | BEAM | General | CH2 | Beam was back for 10 min, and lost after efficiency problem in CSS2 |
VAMOS and MUGAST spectra were checked after the beam was back. Everything looks OK (e.g. similar to previous screenshots)
Waiting for beam again.... |
Fixed | e744s |
Sat Apr 13 05:10:01 2019 |
Mariluz Nikola Nicolas | BEAM | General | CH2 | Beam is back @ 2e4 pps (CATS) |
Beam is back, yeah! |
Fixed | e744s |
Sat Apr 13 06:31:51 2019 |
OttoRun | RUN | General | CH2 | Run122 |
*************************
Run : 122
*************************
Start at 2019-04-13 06:31:24.179531
Run Conditions:
- Operator: Mariluz Nikola Nicolas
- Trigger: MUGAST + Vamos %1000 + CATS %30000
- Target #3
- Beam: 14O
- Intensity: ~4e4
- Brho = 0.5199 Tm
- CATS2 in
- Finger at +12 mm
- WITH AGATA
Comment:
VAMOS is Open
AGATA Coupling |
Fixed | e744s |
Sat Apr 13 06:33:35 2019 |
Mariluz Nikola Nicolas | RUN | General | CH2 | Screenshots run120 v1 |
FAG is 0 because screenshot was taken when run was stopped |
Fixed | e744s |
Sat Apr 13 10:23:01 2019 |
Marion, Kseniia, Dieter, Didier, Guiseppe | ONLINE | General | CH2 | Screenshots run 122 v3 |
|
Fixed | e744s |
Sat Apr 13 10:32:59 2019 |
Iulian | ONLINE | General | CH2 | Screenshots run 122 v3 |
Is missing the scalers |
Fixed | e744s |
Sat Apr 13 11:44:21 2019 |
Marion, Kseniia, Dieter, Didier, Guiseppe, IuliaH | BEAM | General | CH2 | tempory beam interruption |
ventilation problem SPIRAL& - beam stopped for presumably appro. 10 min (PCP info)
beam is back at 11:52 h |
Fixed | e744s |
Sat Apr 13 12:32:03 2019 |
Marion, Kseniia, Dieter, Didier, Guiseppe, IuliaH | ONLINE | General | CH2 | Scalers |
|
Fixed | e744s |
Sat Apr 13 13:42:22 2019 |
Marion, Kseniia, Dieter, Didier, Guiseppe, IuliaH | RUN | General | CH2 | New run 122...1 generated after 4G on disk |
|
Fixed | e744s |
Sat Apr 13 14:19:41 2019 |
Marion, Kseniia, Dieter, Didier, Guiseppe, IuliaH | ONLINE | General | CH2 | Scalers |
|
Fixed | e744s |
Sat Apr 13 14:28:00 2019 |
Marion, Kseniia, Dieter, Didier, Guiseppe, IuliaH | BEAM | General | CH2 | PCP information - beam interruption |
beam interrupted to an octupole (?) failure - prevision to be back after 10-15 min (PCB info)
14:35 h beam is back |