MUST2 SAMURAI_2018 S3-LEB-LPC SUPERNEMO MUGAST EXPAND SCALP GALATRON HiCARI VELO
  MUGAST, Page 66 of 132  Not logged in MUGAST
Status ExpNbr Date Author Type Category Target-Source Subjectdown Text Attachments
Fixede793s Thu Mar 11 03:37:45 2021 LouisOFFLINEGeneralCD2Offline analyis run 531) Some angular distribution were extracted
(without any efficiency corrections) with
gate on Ex btw 0 and 2 MeV (where p orbitals
 AngDistrib.pngEg_Ex.pngETofMM.pngExEg.pngEx_Theta.png 
Fixed  Fri Jul 19 11:46:51 2019 iulianOFFLINEGeneralLiFOffline 112Egamma vs M/Q*9 to check who is 19Ne
Ex in 19Ne all Mugast
Ex vs Egamma for 19Ne
 run112_Egamma_mM_Q.pngrun113_Ex_19Ne.pngrun112_Ex_Egamma_19Ne.pngrun112_KinLines_19Ne.png 
Fixede744s Fri Apr 26 11:29:02 2019 ValerianOTHERSoftwareN/ANotes about the electronicWhile doing the electronic scheme, I saw that
the Inspection line was inducing a bad signal
in the coincidence module between fag and
 Signal_oscilloscope_coinc_module.jpeg 
Fixede744s Wed Apr 10 06:45:53 2019 FrançoisBEAMSocial No beam yet They are about to align the beam from the
cyclotron CIME to the area G1.
  
Fixede744s Wed Apr 10 09:05:33 2019 FrançoisBEAMSocial No beam in G1 yet.The beam is at the entrance of G1.   
Fixede793s Thu Mar 11 23:38:02 2021 Faïrouz, FrancoRUNGeneralCD2No beam at 23h35 for a duration of ~1à mnThe beam operators took the beam at 23h35
for 10 mn. 
 run56_Scalers_23h44.png 
Fixede744s Wed Apr 17 03:03:15 2019 mugastBEAMGeneralCH2No beamNo beam since 02:30
HV of C0 tripping all the time, pcp call
someone to fix it
  
Fixede744s Wed Apr 17 05:14:15 2019 mugastBEAMGeneralCH2No beam[quote="mugast"]No beam since 02:30
HV of C0 tripping all the time, pcp call
someone to fix it[/quote]
  
FixedTEST Mon Mar 4 12:28:26 2019 Valerian and IulianMUST2General3-alphaNo DECS and acq error run 47-48-49. Das Saved after problem fixedFixed. Solution:
1) CENTRUM not configured on GENTRUM Master
2) GMT matrix on GMT3 (2nd slave) was all
 run49_error_acq.png 
Fixede768s Sat Jul 20 01:02:10 2019 Serge & FrancoOTHERGeneral Night shift beam & resync timeline of run 116

00:xx resync Agata #13C
  
Fixede744s Sun Apr 14 15:26:48 2019 Nikola Dieter Nicolas Beyhan KseniiaVAMOSHardwareCH2New thresholds values for DC0 and DC3Thresholds are lowered from 4V to 2V for DC0
Thresholds are lowered from 6V to 4V for
DC3
  
Fixede793s Mon Mar 15 10:08:27 2021 Taras, cyril, LéoRUNGeneralCD2New run scalers (beam stopped)   Screenshot_from_2021-03-15_10-08-59.png 
Fixede744s Sat Apr 13 13:42:22 2019 Marion, Kseniia, Dieter, Didier, Guiseppe, IuliaHRUNGeneralCH2New run 122...1 generated after 4G on disk    
Ongoinge793s Wed Mar 17 15:17:39 2021 Emmanuel COFFLINEGeneral New gamma gamma analysisThe level scheme is based on coherent check
of
1- gamma gamma
 48K.pdf 
FixedTEST Mon Feb 10 18:42:23 2020 Franco&MarlèneGRITHardware New MUGAST detectors MG2 MG6MG2 and MG6 have been mounted in the chamber.

MG2 reference number is 3227_10 thickness=468um
  
Fixedcom2019 Sat Apr 6 03:22:30 2019 Iulian RuxandraRUNSoftware New Kinematics plots (4h of stats)More statistics on the script written by Adrian
and Valerian (first image)
 Kine256_0-256_3.pdfKine256_0-256_3_comparison.pdfElab_vs_ThetaLab_backward.pdf 
Fixede744s Wed Apr 17 13:48:25 2019 Valerian and DiegoRUNSoftwareCH2New Dalitz plot with good angles in vamosThe previous Dalitz plot was wrong as I was
using the angle from vamos as polar angles.
Now that it is corrected we see that this
 DalitzGoodAngle.png 
Fixede786s Tue Jun 25 02:53:18 2019 Sylvain, LouisBEAMGeneralCryo-3HeNO BEAMNo beam since 22h due to signal of neutron
detectors. Then the diffuclty to set the
beam due to thunders. Finally impossible
  
Fixede793s Wed Mar 17 19:19:05 2021 FrancoOFFLINEGeneralCD2Mugast detectors disaligned in ExThe Ex distributions gated on the different
MG detectors show large differences, up to
500 keV. In the attached figure I show as
 detectors_disalignment_Ex.pngEx_aligned_vs_unaligned.png 
FixedTEST Thu Mar 12 14:47:59 2020 Marlène & FrancoGRITHardwareN/AMoving MG9 square to MUVI2- Since we are not using MG6 anymore (card
burnt), we replaced it with MG9 on slot 3
of MUVI2. MUVI4 is now unused. We changed
  

ELOG Home Page