Fixed, com2019, Mon Apr 1 19:53:09 2019, OttoRun, RUN, General, 3-alpha, Run165 
*************************
Run : 165
*************************

Start at 2019-04-01 19:52:02.219719

Run Conditions:
  • Operator: Marlene
  • Trigger: 3 first entries of GMT
  • Target/Source: alpha
  • Beam: N/A
  • Intensity:

Comment: 3 alpha source calibration with all detectors


Stop at 2019-04-02 09:02:53.007743
Stop comment:
Fixed, com2019, Tue Apr 2 08:52:16 2019, Freddy, MUST2, General, 3-alpha, PEDESTAL save - run 165 
Normalized Pedestal value loaded in DAS for run 165 (3-alpha)

folder: /home/mugast/ganacq_manip/mugast/das-save/pedestal-save/run165

NB: Not sure when this pedestal values were read from the board, in principle should have been read just before the run.
Fixed, com2019, Tue Apr 2 09:08:05 2019, OttoRun, RUN, General, 3-alpha, Run166 2019_04_02_run165_3alphas_w_and_wo_pedestals.png
*************************
Run : 166
*************************

Start at 2019-04-02 09:07:03.468248

Run Conditions:
  • Operator: Freddy
  • Trigger: 3 first entries of GMT
  • Target/Source: alpha
  • Beam: N/A
  • Intensity:

Comment: 3 alpha source calibration with all detectors without pedestal subtraction to check their alignment


Stop at 2019-04-02 09:13:46.822878
Stop comment:
Fixed, com2019, Tue Apr 2 09:22:02 2019, OttoRun, RUN, General, N/A, Run167 2019_03_29_run167_TC_TACs.png2019_03_29_run163_ADC_entry.png
*************************
Run : 167
*************************

Start at 2019-04-02 09:20:38.358334

Run Conditions:
  • Operator: Iulian
  • Trigger: Trigger 9 -> Time Calibrator
  • Target/Source: N/A
  • Beam: N/A
  • Intensity:

Comment: Time Calibrator 640ns range and 20 ns period. Calbration of the TACs 2-8.


Stop at 2019-04-02 09:32:21.549086
Stop comment:

Important: The range on the ADC 8th entry (channel 7, coresponding to T_Vamos_Agata) was chnaged to 500 ns
Fixed, com2019, Tue Apr 2 09:36:56 2019, OttoRun, RUN, General, N/A, Run168 2019_04_02_run168_TC_TACs.png
*************************
Run : 168
*************************

Start at 2019-04-02 09:36:43.463822

Run Conditions:
  • Operator: Iulian
  • Trigger: Trigger 9 -> Time Calibrator
  • Target/Source: N/A
  • Beam: N/A
  • Intensity:

Comment: Time Calibrator 640ns range and 10 ns period. Calbration of the TACs 2-8.


Stop at 2019-04-02 09:47:27.305514
Stop comment:
Fixed, com2019, Tue Apr 2 09:50:54 2019, OttoRun, RUN, General, N/A, Run169 2019_04_02_run169_TC_TACs.png
*************************
Run : 169
*************************

Start at 2019-04-02 09:50:15.668043

Run Conditions:
  • Operator: Iulian
  • Trigger: Trigger 9 -> Time Calibrator
  • Target/Source: N/A
  • Beam: N/A
  • Intensity:

Comment: Time Calibrator 640ns range and 10 ns period. Calbration of the TACs 1,3-8.


Stop at 2019-04-02 10:01:42.158045
Stop comment:
Fixed, com2019, Tue Apr 2 10:03:15 2019, OttoRun, RUN, General, N/A, Run170 2019_04_02_run170_TC_TACs.png
*************************
Run : 170
*************************

Start at 2019-04-02 10:03:09.183277

Run Conditions:
  • Operator: Iulian
  • Trigger: Trigger 9 -> Time Calibrator
  • Target/Source: N/A
  • Beam: N/A
  • Intensity:

Comment: Time Calibrator 640ns range and 20 ns period. Calbration of the TACs 1,3-8.


Stop at 2019-04-02 10:09:16.738041
Stop comment:
Fixed, TEST, Tue Apr 2 10:38:38 2019, OttoRun, RUN, General, N/A, Run171 first run with ADC Labels updated with GECO Added_Labes_TACs_ADC.png
Used GECO action list to have the new labels:
ADC1_0 -> T_Cats1_2
ADC1_1 -> T_Si_Cats1
ADC1_2 -> T_Si_Vamos
ADC1_3 -> T_Si_Agata
ADC1_4 -> T_Vamos_Cats1
ADC1_5 -> T_Cats1_HF
ADC1_6 -> T_Fag_HF
ADC1_7 -> T_Vamos_Agata
ADC1_8 -> E_Agata ( This ADC channel remains to be tested)


*************************
Run : 171
*************************

Start at 2019-04-02 10:38:08.929663

Run Conditions:
  • Operator: Iulian
  • Trigger: Bad run (just test labels update
  • Target/Source: N/A
  • Beam: N/A
  • Intensity:

Comment: Bad run


Stop at 2019-04-02 10:40:18.543739
Stop comment: end bad run
Fixed, TEST, Tue Apr 2 15:16:06 2019, OttoRun, RUN, General, N/A, Run172 
*************************
Run : 172
*************************

Start at 2019-04-02 15:15:56.369693

Run Conditions:
  • Operator: Iulian
  • Trigger: Bad run
  • Target/Source: N/A
  • Beam: N/A
  • Intensity:

Comment: Bad run


Stop at 2019-04-02 15:23:39.820362
Stop comment:
Fixed, com2019, Tue Apr 2 16:24:06 2019, marlene freddy, OTHER, General, N/A, Commissioning proposal MUGAST_commissioning-3.pdf
Fixed, TEST, Tue Apr 2 16:34:13 2019, OttoRun, RUN, General, N/A, Run172 
*************************
Run : 172
*************************

Start at 2019-04-02 16:34:11.711596

Run Conditions:
  • Operator: Iulian
  • Trigger: Bad run
  • Target/Source: N/A
  • Beam: N/A
  • Intensity:

Comment: Bad run


Stop at 2019-04-02 16:41:00.861044
Stop comment:
Fixed, com2019, Tue Apr 2 17:15:47 2019, Freddy, OTHER, General, N/A, DWBA Cross section 16Odp17O_s12_6AMeV.dat
16O(d,p)17O*(1/2+) @ 6 MeV/nucleon - SF = 1
Fixed, com2019, Tue Apr 2 18:39:55 2019, mugast, GRIT, General, N/A, Targets 
Targets : in the order of the scaler

1- CD2 5.5 mg/cm2
2- CD2 0.5 mg/cm2
3- CD2 1 mg/cm2
4- mask
5- hole
6- CD2 1 mg/cm2

There are spacers to put on the target loader which height correspond each to one target position. If no spacer is used, the target is the 1st one (5.5mg/cm2).
Fixed, TEST, Tue Apr 2 22:04:31 2019, OttoTime, RUN, General, N/A, TimeCalibratorRun 
*** Run Time Calibrator FSC ***
- Run: 173
- MUVI: MUVI1
- Side : MUFEE X (Junction)
- Telescope: 1, 2, 3, 4
Fixed, TEST, Tue Apr 2 22:15:15 2019, OttoTime, RUN, General, N/A, TimeCalibratorRun 
*** Run Time Calibrator FSC ***
- Run: 174
- MUVI: MUVI1
- Side : MUFEE Y (Ohmic)
- Telescope: 1, 2, 3, 4
Fixed, TEST, Tue Apr 2 22:25:36 2019, OttoTime, RUN, General, N/A, TimeCalibratorRun 
*** Run Time Calibrator FSC ***
- Run: 175
- MUVI: MUVI2
- Side : MUFEE X (Junction)
- Telescope: 1, 2, 3, 4
Fixed, TEST, Tue Apr 2 22:35:32 2019, OttoTime, RUN, General, N/A, TimeCalibratorRun 
*** Run Time Calibrator FSC ***
- Run: 176
- MUVI: MUVI2
- Side : MUFEE Y (Ohmic)
- Telescope: 1, 2, 3, 4
Fixed, TEST, Tue Apr 2 22:45:26 2019, OttoTime, RUN, General, N/A, TimeCalibratorRun 
*** Run Time Calibrator FSC ***
- Run: 177
- MUVI: MUVI3
- Side : MUFEE X (Junction)
- Telescope: 1, 2, 3, 4
Fixed, TEST, Tue Apr 2 22:55:17 2019, OttoTime, RUN, General, N/A, TimeCalibratorRun 
*** Run Time Calibrator FSC ***
- Run: 178
- MUVI: MUVI3
- Side : MUFEE Y (Ohmic)
- Telescope: 1, 2, 3, 4
Fixed, com2019, Wed Apr 3 10:43:53 2019, OttoRun, RUN, General, N/A, Run109 
*************************
Run : 109
*************************

Start at 2019-04-03 10:41:45.618344

Run Conditions:
  • Operator: ANONYMOUS
  • Trigger: VAMOS PULSER DAQ COUPLING TEST !
  • Target/Source: N/A
  • Beam: N/A
  • Intensity:

Comment:
WTF Technology!
MISSING ENTRIES PB


Stop at 2019-04-03 10:47:55.926459
Stop comment: BAD MERGE !