Fixed, e786s, Mon Jun 24 15:53:27 2019, OttoRun, RUN, General, Cryo-3He, Run53
|
*************************
[SIZE=3][B]Run : 53[/B][/SIZE]
*************************
|
Fixed, e786s, Mon Jun 24 16:30:19 2019, OttoRun, RUN, General, Cryo-3He, Run55 
|
*************************
[SIZE=3][B]Run : 55[/B][/SIZE]
*************************
|
Fixed, e786s, Mon Jun 24 16:50:48 2019, Valerian and Adrien, OFFLINE, Software, Cryo-3He, 3He-d kinematics
|
To plot those kinematics, there is a macros called kine.cxx
The first plot correspond to the Silicon energy in MUGAST corrected for energy loss (some improvement might be needed)
|
Fixed, e786s, Mon Jun 24 17:42:33 2019, OttoRun, RUN, General, Cryo-3He, Run56
|
*************************
[SIZE=3][B]Run : 56[/B][/SIZE]
*************************
|
Fixed, TEST, Mon Jun 24 18:26:05 2019, OttoH.V., OTHER, Hardware, N/A, HVM_SUMMARY
|
[SIZE=5][COLOR=green][B]*** hvm watcher summary ***[/B] [/COLOR][/SIZE]
[SIZE=2][COLOR=green]+10v/mg [/COLOR] Slot: [COLOR=blue]5 [/COLOR] (A1516B) Channel:[COLOR=blue]5 [/COLOR] Vmon: [COLOR=blue] 10 V [/COLOR] Imon:
[COLOR=blue]0.407 A [/COLOR] Status: [COLOR=green]On[/COLOR]
|
Fixed, TEST, Mon Jun 24 18:26:06 2019, OttoH.V., OTHER, Hardware, N/A, HVM_SUMMARY
|
[SIZE=5][COLOR=green][B]*** hvm watcher summary ***[/B] [/COLOR][/SIZE]
[SIZE=2][COLOR=green] [/COLOR] Slot: [COLOR=blue]8 [/COLOR] (A1821H) Channel:[COLOR=blue]1 [/COLOR] Vmon: [COLOR=blue] 0 V [/COLOR] Imon:
[COLOR=blue] 0 uA[/COLOR] Status: [COLOR=pink]Off[/COLOR]
|
Fixed, e786s, Mon Jun 24 20:39:54 2019, Freddy, RUN, General, Cryo-3He, run 56 screenshots
|
|
Fixed, e786s, Mon Jun 24 21:42:11 2019, mugast, RUN, General, Cryo-3He, Beam and cryo target
|
The beam is fluctuating between 18 kHz and 22 kHz in VAMOS (24 to 27 kHz in CATS1)
Division on CATS1 trigger is 1000
Division on VAMOS trigger is 1000 in the GMT.
|
Fixed, e786s, Tue Jun 25 02:46:32 2019, Sylvain, Louis, OFFLINE, General, Cryo-3He, Offline analysis run 56 
|
Offline analysis of run 56 has been perfomed. On plots, kinematics lines and excitation energy are shown using gate on 47K in vamos. Then agata spectra
is shown using gate on 47K in VAMOS un valid event in MUGAST. One can (may be) distinguish a peak at 368keV... |
Fixed, e786s, Tue Jun 25 02:53:18 2019, Sylvain, Louis, BEAM, General, Cryo-3He, NO BEAM
|
No beam since 22h due to signal of neutron detectors. Then the diffuclty to set the beam due to thunders. Finally impossible to get back the beam because
source sample is empty. No beam before tomorow 12h... |
Fixed, TEST, Tue Jun 25 03:43:20 2019, OttoH.V., OTHER, Hardware, N/A, HVM_SUMMARY
|
[SIZE=5][COLOR=green][B]*** hvm watcher summary ***[/B] [/COLOR][/SIZE]
[SIZE=2][COLOR=green]+10v/mg [/COLOR] Slot: [COLOR=blue]5 [/COLOR] (A1516B) Channel:[COLOR=blue]5 [/COLOR] Vmon: [COLOR=blue] 10 V [/COLOR] Imon:
[COLOR=blue]0.407 A [/COLOR] Status: [COLOR=green]On[/COLOR]
|
Fixed, TEST, Tue Jun 25 03:43:21 2019, OttoH.V., OTHER, Hardware, N/A, HVM_SUMMARY
|
[SIZE=5][COLOR=green][B]*** hvm watcher summary ***[/B] [/COLOR][/SIZE]
[SIZE=2][COLOR=green] [/COLOR] Slot: [COLOR=blue]8 [/COLOR] (A1821H) Channel:[COLOR=blue]1 [/COLOR] Vmon: [COLOR=blue] 0 V [/COLOR] Imon:
[COLOR=blue] 0 uA[/COLOR] Status: [COLOR=pink]Off[/COLOR]
|
Fixed, e786s, Tue Jun 25 03:44:12 2019, Louis, Sylvain, AGATA, General, Cryo-3He, Run 56 : AGATA gamma rays in coincidences with VAMOS, MUST2 and/or MUGAST  
|
As attachment are some gamma spectra we obtained while trying several conditions on the run 056.
*Beam excitation has been investigated by gating on PID in VAMOS. Both 46Ar and 47K were selected. Excitation of 46Ar appears clearly while no clear conclusions |
Fixed, TEST, Tue Jun 25 03:45:32 2019, OttoH.V., OTHER, Hardware, N/A, HVM_ERROR
|
[SIZE=5][COLOR=red][B]*** hvm watcher error ***[/B] [/COLOR][/SIZE]
[SIZE=4][COLOR=green]FP_DC_Wi1 [/COLOR] Slot: [COLOR=blue]6 [/COLOR] (A1821H) Channel:[COLOR=blue]0 [/COLOR] Vmon: [COLOR=blue]624.75 V [/COLOR]
Imon: [COLOR=blue]0.996 uA[/COLOR] Status: [COLOR=red]OVER CURRENT[/COLOR]
|
Fixed, TEST, Tue Jun 25 03:47:51 2019, OttoH.V., OTHER, Hardware, N/A, HVM_ERROR
|
[SIZE=5][COLOR=red][B]*** hvm watcher error ***[/B] [/COLOR][/SIZE]
[SIZE=4][COLOR=green]FP_DC_Wi1 [/COLOR] Slot: [COLOR=blue]6 [/COLOR] (A1821H) Channel:[COLOR=blue]0 [/COLOR] Vmon: [COLOR=blue] 7.25 V [/COLOR] Imon:
[COLOR=blue] 0 uA[/COLOR] Status: [COLOR=red]INTERNAL TRIP[/COLOR]
|
Fixed, TEST, Tue Jun 25 04:16:51 2019, OttoH.V., OTHER, Hardware, N/A, HVM_SUMMARY
|
[SIZE=5][COLOR=green][B]*** hvm watcher summary ***[/B] [/COLOR][/SIZE]
[SIZE=2][COLOR=green]+10v/mg [/COLOR] Slot: [COLOR=blue]5 [/COLOR] (A1516B) Channel:[COLOR=blue]5 [/COLOR] Vmon: [COLOR=blue] 10 V [/COLOR] Imon:
[COLOR=blue]0.407 A [/COLOR] Status: [COLOR=green]On[/COLOR]
|
Fixed, TEST, Tue Jun 25 04:16:52 2019, OttoH.V., OTHER, Hardware, N/A, HVM_ERROR
|
[SIZE=5][COLOR=red][B]*** hvm watcher error ***[/B] [/COLOR][/SIZE]
[SIZE=4][COLOR=green]FP_DC_Wi1 [/COLOR] Slot: [COLOR=blue]6 [/COLOR] (A1821H) Channel:[COLOR=blue]0 [/COLOR] Vmon: [COLOR=blue] 0 V [/COLOR] Imon:
[COLOR=blue] 0 uA[/COLOR] Status: [COLOR=red]INTERNAL TRIP[/COLOR]
|
Fixed, TEST, Tue Jun 25 04:16:52 2019, OttoH.V., OTHER, Hardware, N/A, HVM_SUMMARY
|
[SIZE=5][COLOR=green][B]*** hvm watcher summary ***[/B] [/COLOR][/SIZE]
[SIZE=2][COLOR=green] [/COLOR] Slot: [COLOR=blue]8 [/COLOR] (A1821H) Channel:[COLOR=blue]1 [/COLOR] Vmon: [COLOR=blue] 0 V [/COLOR] Imon:
[COLOR=blue] 0 uA[/COLOR] Status: [COLOR=pink]Off[/COLOR]
|
Fixed, e786s, Tue Jun 25 08:23:58 2019, Valerian , BEAM, General, N/A, Beam status
|
Currently there is no beam since 22h-> Thunder + no more 48Ca sample. The sample was out during the night.
The "sourcier" on-call arrived at 8h15. By talking to people in shift at the PCP they told me that more will be known ~10am-11am. Beam is expected to be |
Fixed, e786s, Tue Jun 25 10:51:59 2019, OttoRun, RUN, General, 152Eu, Run57
|
*************************
[SIZE=3][B]Run : 57[/B][/SIZE]
*************************
|
|