Fixede744s Thu Apr 11 07:00:17 2019 iulianBEAMGeneralCH2ToDo List and plan for todayTo Do/Understand
1) T_Vamos_Cats1 in Mugast and T_FPMW_CATS2
in Vamos are not working. I suspect it is
 run275_tacs_mugast.png 
Fixede744s Thu Apr 11 07:17:33 2019 OttoRunRUNGeneralCH2Run75[quote="OttoRun"]*************************
  [SIZE=3][B]Run  : 75[/B][/SIZE]
*************************
 12x 
Fixede744s Thu Apr 11 07:30:15 2019 mugastBEAMSocialN/ABeam stopThe beam will be back around 8:30.   
Fixede744s Thu Apr 11 08:01:12 2019 OttoRunRUNGeneralCH2Run76*************************
  [SIZE=3][B]Run  : 76[/B][/SIZE]
*************************
  
Fixede744s Thu Apr 11 08:55:23 2019 OttoRunRUNGeneralCH2Run77*************************
  [SIZE=3][B]Run  : 77[/B][/SIZE]
*************************
 23x 
Fixede744s Thu Apr 11 09:05:37 2019 mugastCATSGeneralN/ACATS HV changed to 580CATS HV changed from 600V to 580V.   
Fixede744s Thu Apr 11 10:38:13 2019 Adrien and ValerianBEAMGeneralN/AThey are preparing 14O beamNews from  (edit after talking to Pierre D.)
[LIST]
[*]  They are preparing the 14O beam.
  
Fixede744s Thu Apr 11 11:26:52 2019 AdrienMUST2GeneralCH2TOF in MUST2 MM3 is now fixedThe E-TOF plot in MM3 was showing a 5MeV threshold.
After investigation the 12 strip was not
disable on MM2 to MM4, and particularly noisy
 ETOF_14N.pngEDE_14N.pngImpact_14N.png 
Fixede744s Thu Apr 11 11:36:09 2019 ValerianOFFLINESoftwareCH2Comparison between the two e744Current calibration is off, a shift of -1.5MeV
was done to reproduce the previous data.
 current_exp_old_e744.png 
Fixede744s Thu Apr 11 13:43:26 2019 ValerianOFFLINESoftwareCH2Target position for 14N runs   XY_run14N.pngXshift_run14N.pngYshift_run14N.png 
Fixede744s Thu Apr 11 14:03:45 2019 ValerianCATSHardwareN/AIn case of a CATS2 trippedCurrently, CATS2 is inserted, if the window
:
  
Fixede744s Thu Apr 11 15:16:10 2019 Adrien, Valerian, LouisCATSGeneralCH2run77 CATS efficiencyCATS efficiency has been computed for run
77 using T_FagHF an  T_Si_Cats1 with different
triggers:
  
Fixede744s Thu Apr 11 16:07:59 2019 Valerian and LouisOFFLINESoftwareCH2HF resolutionUsing the value of the HF=83,4ns. We can obtain
the calibrated plot of T_CATS2_HF which is
joined and gives us roughly a 2-3 ns resolution
 T_CATS2_HFns.png 
Fixede744s Thu Apr 11 16:56:34 2019 OttoRunRUNGeneralEmptyRun78*************************
  [SIZE=3][B]Run  : 78[/B][/SIZE]
*************************
  
Fixede744s Thu Apr 11 17:08:39 2019 OttoRunRUNGeneralEmptyRun79*************************
  [SIZE=3][B]Run  : 79[/B][/SIZE]
*************************
  
Fixede744s Thu Apr 11 17:35:21 2019 FrançoisBEAMGeneral 14O beam is in G1 since 17H00alignment of the beam in VAMOS
intensity ~ 5x10^3 pps
  
Fixede744s Thu Apr 11 17:37:29 2019 Valérian, Chloé and FrançoisOTHERHardware changes in the electronicChanges made in the electronic during the
break between 14N and 14O
  
Fixede744s Thu Apr 11 17:38:24 2019 mugast (beyhan)BEAMGeneral 14O8+ beam characteristicsBrho 14O8+ = 0.69186 Tm

 image1.jpegIMG_1581.jpg 
Fixede744s Thu Apr 11 17:38:28 2019 iulianRUNHardwareEmptySetting trigger Vamos and CatsRemoved division %40000 on Cats and %1000
on Vamos.
  
Fixede744s Thu Apr 11 17:43:44 2019 OttoRunRUNGeneralEmptyRun80*************************
  [SIZE=3][B]Run  : 80[/B][/SIZE]
*************************
  