MUST2 SAMURAI_2018 S3-LEB-LPC SUPERNEMO MUGAST EXPAND SCALP GALATRON HiCARI VELO
  MUGAST, Page 50 of 132  Not logged in MUGAST
Status ExpNbrdown Date Author Type Category Target-Source Subject
Fixede744s Thu Apr 11 07:00:17 2019 iulianBEAMGeneralCH2ToDo List and plan for today
To Do/Understand
1) T_Vamos_Cats1 in Mugast and T_FPMW_CATS2 in Vamos are not working. I suspect it is the same reason, meaning stop arrives before start. Longer delay or inverse putting Cats2-Fag validated.
2) MM3_E_TOF there is a 5 MeV threshold see below?

For today:
1) We give the beam back to them at 10 am.
2) Analyse the data from RUN 74 & 75 to see the excitation function for 1H(14N,p)
3) If we have the beam back, take more data merged with Agata. Intensity around 2e+5 pps to protect CATS2.
4) If Vamos/Mugast need debugging for reconstruction/validation they have priority.

Summary of the night :
1) Measured the target thicknesses for the targets: 1) Hole 2) CH2 105 um 3) CH2 100 um 4) C 70 um 5) CH2 73 um
2) The C target was not very homogeneous, meaning that was dramatically spreading the momentum distribution of the beam charge states.
3) Vamos debugging went forward, transmission was 95% with Cats2 in with 2e+4 pps beam intensity
4) At 4h30 started the statistic run with Vamos setted at a Brho of 0.437 Tm to completely remove 14N7+ and all others from the focal plane. The beam spot was about 50 mm pied a pied ... This makes imposible the use
Attachment 1: run275_tacs_mugast.png
run275_tacs_mugast.png
Fixede744s Thu Apr 11 07:17:33 2019 OttoRunRUNGeneralCH2Run75

OttoRun wrote:
*************************
Run : 75
*************************

Start at 2019-04-11 06:40:54.479084

Run Conditions:
  • Operator: A. Lemasson
  • Trigger: Mugast & Vamos % 1000 & Cats2 % 40000
  • Target/Source: CH2 105 um (Position 2)
  • Beam: 14N
  • Intensity: ~ 2e+5
  • Brho = 0.437 Tm
  • CATS 2 IN


Comment:
Attachment 1: run75_1.png
run75_1.png
Attachment 2: run75_2.png
run75_2.png
Attachment 3: run75_3.png
run75_3.png
Attachment 4: run75_4.png
run75_4.png
Attachment 5: run75_5.png
run75_5.png
Attachment 6: run75_6.png
run75_6.png
Attachment 7: run75_7.png
run75_7.png
Attachment 8: run75_8.png
run75_8.png
Attachment 9: run75_9.png
run75_9.png
Attachment 10: run75_10.png
run75_10.png
Attachment 11: run75_11.png
run75_11.png
Attachment 12: run75_scaler.png
run75_scaler.png
Fixede744s Thu Apr 11 07:30:15 2019 mugastBEAMSocialN/ABeam stop
The beam will be back around 8:30.
Fixede744s Thu Apr 11 08:01:12 2019 OttoRunRUNGeneralCH2Run76
*************************
Run : 76
*************************

Start at 2019-04-11 07:59:50.438662

Run Conditions:
  • Operator: Nikola, Marion
  • Trigger: Mugast & Vamos % 1000 & Cats2 % 40000
  • Target/Source: CH2 105 um (Position 2)
  • Beam: 14N
  • Intensity: ~ 2e+5
  • Brho = 0.437 Tm
  • CATS 2 IN


Comment: Beam stopped (Balise).

Stop at 2019-04-11 08:33:56.045621
Stop comment:
Fixede744s Thu Apr 11 08:55:23 2019 OttoRunRUNGeneralCH2Run77
*************************
Run : 77
*************************

Start at 2019-04-11 08:54:59.257928

Run Conditions:
  • Operator: Nikola, Marion
  • Trigger: Mugast & Vamos % 1000 & Cats2 % 40000
  • Target/Source: CH2 105 um (Position 2)
  • Beam: 14N
  • Intensity: ~ 2.2e+5
  • Brho = 0.437 Tm
  • CATS 2 IN


Comment:

Stop at 2019-04-11 10:08:08.427024
Stop comment: Beam stopped for radiactive preparation
Attachment 1: run77_tab0.png
run77_tab0.png
Attachment 2: run77_tab2.png
run77_tab2.png
Attachment 3: run77_tab3.png
run77_tab3.png
Attachment 4: run77_tab4.png
run77_tab4.png
Attachment 5: run77_tab5.png
run77_tab5.png
Attachment 6: run77_tab6.png
run77_tab6.png
Attachment 7: run77_time_calibrator.png
run77_time_calibrator.png
Attachment 8: run77_tab8.png
run77_tab8.png
Attachment 9: run77_tab9.png
run77_tab9.png
Attachment 10: run77_tab10.png
run77_tab10.png
Attachment 11: run77_tab11.png
run77_tab11.png
Attachment 12: run77_tab1.png
run77_tab1.png
Attachment 13: Run77_1.png
Run77_1.png
Attachment 14: Run77_2.png
Run77_2.png
Attachment 15: Run77_3.png
Run77_3.png
Attachment 16: Run77_4.png
Run77_4.png
Attachment 17: Run77_5.png
Run77_5.png
Attachment 18: Run77_6.png
Run77_6.png
Attachment 19: Run77_7.png
Run77_7.png
Attachment 20: Run77_8.png
Run77_8.png
Attachment 21: Run77_9.png
Run77_9.png
Attachment 22: Run77_10.png
Run77_10.png
Attachment 23: Run77_11.png
Run77_11.png
Fixede744s Thu Apr 11 09:05:37 2019 mugastCATSGeneralN/ACATS HV changed to 580
CATS HV changed from 600V to 580V.
Fixede744s Thu Apr 11 10:38:13 2019 Adrien and ValerianBEAMGeneralN/AThey are preparing 14O beam
News from (edit after talking to Pierre D.)
  • They are preparing the 14O beam.
  • We should have 14O at moderate intensity early afternoon.
  • The beam should be at full intensity inG1 around 21h-23h.
  • Run end Wenesday 18h sharp
  • Omar is on call at any time
Fixede744s Thu Apr 11 11:26:52 2019 AdrienMUST2GeneralCH2TOF in MUST2 MM3 is now fixed
The E-TOF plot in MM3 was showing a 5MeV threshold.
After investigation the 12 strip was not disable on MM2 to MM4, and particularly noisy on MM3, killing the counts at small angle where most of the proton are.

After disabling the Strip 12 all 4 telescope show the same amount of statistics.

I added the Impact matrix and the E-DE plot for each of the forward telescope as well. Looks like the beam is not centered but shifted. Need more investigation.

The online need to be restarted to take this into account.
Attachment 1: ETOF_14N.png
ETOF_14N.png
Attachment 2: EDE_14N.png
EDE_14N.png
Attachment 3: Impact_14N.png
Impact_14N.png
Fixede744s Thu Apr 11 11:36:09 2019 ValerianOFFLINESoftwareCH2Comparison between the two e744
Current calibration is off, a shift of -1.5MeV was done to reproduce the previous data.
Attachment 1: current_exp_old_e744.png
current_exp_old_e744.png
Fixede744s Thu Apr 11 13:43:26 2019 ValerianOFFLINESoftwareCH2Target position for 14N runs
Attachment 1: XY_run14N.png
XY_run14N.png
Attachment 2: Xshift_run14N.png
Xshift_run14N.png
Attachment 3: Yshift_run14N.png
Yshift_run14N.png
Fixede744s Thu Apr 11 14:03:45 2019 ValerianCATSHardwareN/AIn case of a CATS2 tripped
Currently, CATS2 is inserted, if the window :

CATS2 has tripped appear, one should do the following :

  • Open a terminal
  • Type: HV
  • Username is : admin
  • Password is : admin
  • Press enter twice

The list of channels is going to appear.

  • Using the arrow of the keyboard, go down until you reach cats2
  • then go right until you reach Off
  • press space, the dectector should start ramping up
  • If it trips again, you can try to put voltage to cats1 (right above cats2)

Two possibility :

  • If cats1 trip it is the gas bottle that is empty call : 07 83 34 30 81 (Sebastien)
  • If cats1 doesn't trip try cats2 again, and if it trips lower the voltage of cats2

To lower the voltage of cats2 : go to the left until you reach the first cell after cats2 name and lower the voltage 10 volts and try to start cats2 again.

THEN CLOSE THE TERMINAL
Fixede744s Thu Apr 11 15:16:10 2019 Adrien, Valerian, LouisCATSGeneralCH2run77 CATS efficiency
CATS efficiency has been computed for run 77 using T_FagHF an T_Si_Cats1 with different triggers:

Trigger GATCONF_MASTER<8 (MUST+Mugast) : 94%
Trigger GATCONF_MASTER=4 (MUST) : 99.4%
Trigger GATCONF_MASTER=2 (square) : 85%
Trigger GATCONF_MASTER=1 (trapezoidal+annular) : 22%

The 22% resolution is due to the fact that the trapezoidal detectors are noisy. Doing the same on an analysed run we obtain ~ 85% efficiency
Fixede744s Thu Apr 11 16:07:59 2019 Valerian and LouisOFFLINESoftwareCH2HF resolution
Using the value of the HF=83,4ns. We can obtain the calibrated plot of T_CATS2_HF which is joined and gives us roughly a 2-3 ns resolution for the HF
Attachment 1: T_CATS2_HFns.png
T_CATS2_HFns.png
Fixede744s Thu Apr 11 16:56:34 2019 OttoRunRUNGeneralEmptyRun78
*************************
Run : 78
*************************

Start at 2019-04-11 16:55:28.720017

Run Conditions:
  • Operator: Adrien
  • Trigger: Mugast
  • Target/Source: hole
  • Beam: 14O
  • Intensity: ~ 3e+3
  • Brho = ?? Tm
  • !CATS/VAMOS (CATS Efficiency)! : XXXX

Comment:

Alignign beam, daq on for online monitoring

Stop at 2019-04-11 17:07:49.331973
Stop comment: changing trigger to vamos
Fixede744s Thu Apr 11 17:08:39 2019 OttoRunRUNGeneralEmptyRun79
*************************
Run : 79
*************************

Start at 2019-04-11 17:08:21.837538

Run Conditions:
  • Operator: Adrien
  • Trigger: VAMOS
  • Target/Source: hole
  • Beam: 14O
  • Intensity: ~ 3e+3
  • Brho = ?? Tm
  • !CATS/VAMOS (CATS Efficiency)! : XXXX

Comment:

Aligning beam, daq on for online monitoring

Stop at 2019-04-11 17:31:48.540765
Stop comment: Entering to Remove CATS2 and remove VAMOS %1000
Fixede744s Thu Apr 11 17:35:21 2019 FrançoisBEAMGeneral 14O beam is in G1 since 17H00
alignment of the beam in VAMOS
intensity ~ 5x10^3 pps
Fixede744s Thu Apr 11 17:37:29 2019 Valérian, Chloé and FrançoisOTHERHardware changes in the electronic
Changes made in the electronic during the break between 14N and 14O

1) T_VAMOS-CATS1
it was not connected. We added 500 ns delay in CATS1 (CATS2 in reality) (48+150ns before)


2) T_CATS1_HF
range changed from 2µs to 200 ns
Fixede744s Thu Apr 11 17:38:24 2019 mugast (beyhan)BEAMGeneral 14O8+ beam characteristics
Brho 14O8+ = 0.69186 Tm


update Adrien:
La dream team de Division (non) Opération n'arrive pas a mesurer l’énergie en sortie de CIME (WTF??!!)
Du coup ils ont mis une énergie fausse mais avec une super précision de 1.8 Mev/A dans la fiche.

#onlyatganil
Attachment 1: image1.jpeg
image1.jpeg
Attachment 2: IMG_1581.jpg
IMG_1581.jpg
Fixede744s Thu Apr 11 17:38:28 2019 iulianRUNHardwareEmptySetting trigger Vamos and Cats
Removed division %40000 on Cats and %1000 on Vamos.

Removed Cats2 from the beam
Fixede744s Thu Apr 11 17:43:44 2019 OttoRunRUNGeneralEmptyRun80
*************************
Run : 80
*************************

Start at 2019-04-11 17:42:44.178301

Run Conditions:
  • Operator: Adrien
  • Trigger: VAMOS %1
  • Target/Source: hole
  • Beam: 14O
  • Intensity: ~ 5e+3
  • Brho = 0.69186 Tm
  • !CATS/VAMOS (CATS Efficiency)! : XXXX

Comment:
After removing division on Cats and Vamos.
Aligning beam, daq on for online monitoring

Stop at 2019-04-11 18:50:52.122268
Stop comment: Stop to remove target hole

ELOG Home Page