MUST2 SAMURAI_2018 S3-LEB-LPC SUPERNEMO MUGAST EXPAND SCALP GALATRON HiCARI VELO
  MUGAST, Page 3 of 132  Not logged in MUGAST
Status ExpNbr Date Authordown Type Category Target-Source Subject
Fixede744s Wed Apr 17 01:53:04 2019 mugastONLINEGeneralCH2Log and scalers RUN 136 @01:40
Attachment 1: run136_scaler_01h41.png
run136_scaler_01h41.png
Attachment 2: run136_VAMOS_2_1.png
run136_VAMOS_2_1.png
Attachment 3: run136_VAMOS_2_2.png
run136_VAMOS_2_2.png
Attachment 4: run136_VAMOS_2_3.png
run136_VAMOS_2_3.png
Attachment 5: run136_VAMOS_2_4.png
run136_VAMOS_2_4.png
Attachment 6: run136_VAMOS_2_5.png
run136_VAMOS_2_5.png
Attachment 7: run136_VAMOS_2_6.png
run136_VAMOS_2_6.png
Attachment 8: run136_VAMOS_2_7.png
run136_VAMOS_2_7.png
Attachment 9: run136_VAMOS_2_8.png
run136_VAMOS_2_8.png
Attachment 10: run136_VAMOS_2_9.png
run136_VAMOS_2_9.png
Attachment 11: run136_VAMOS_2_10.png
run136_VAMOS_2_10.png
Attachment 12: run136_VAMOS_2_11.png
run136_VAMOS_2_11.png
Attachment 13: run136_Mugast_2_1.png
run136_Mugast_2_1.png
Attachment 14: run136_Mugast_2_2.png
run136_Mugast_2_2.png
Attachment 15: run136_Mugast_2_3.png
run136_Mugast_2_3.png
Attachment 16: run136_Mugast_2_4.png
run136_Mugast_2_4.png
Attachment 17: run136_Mugast_2_5.png
run136_Mugast_2_5.png
Attachment 18: run136_Mugast_2_6.png
run136_Mugast_2_6.png
Attachment 19: run136_Mugast_2_7.png
run136_Mugast_2_7.png
Attachment 20: run136_Mugast_2_8.png
run136_Mugast_2_8.png
Fixede744s Wed Apr 17 02:00:55 2019 mugastBEAMGeneralCH2Beam lost

mugast wrote:

mugast wrote:
About 1:00am we lost the beam.
We call pcp and they will fix in 15 min
At 01:20 we recover the beam



At 01:30 we lost other time the beam for 5 min


At 02:00 again and we recovered soon. Seems unstable
Fixede744s Wed Apr 17 03:03:15 2019 mugastBEAMGeneralCH2No beam
No beam since 02:30
HV of C0 tripping all the time, pcp call someone to fix it
Fixede744s Wed Apr 17 04:06:28 2019 mugastRUNGeneralN/ARun 136_1 CATS lost efficiency with respect to VAMOS
Attachment 1: run135-efficiencies-2.png
run135-efficiencies-2.png
Fixede744s Wed Apr 17 05:14:15 2019 mugastBEAMGeneralCH2No beam

mugast wrote:
No beam since 02:30
HV of C0 tripping all the time, pcp call someone to fix it



We recover the beam at 05:05 with oscillations
FixedTEST Tue May 28 11:08:10 2019 mugastMUST2Hardware3-alphaMG3 is tripping
MG3T is tripping, tryied to set max current to 20uA but it still trip around 30V.
Fixede786s Wed Jun 12 17:59:01 2019 mugastOTHERSoftware Online Energy Calibration
Updated Online Energy calibration for MUGAST, based on run_0231 data
Attachment 1: x_E_cal.png
x_E_cal.png
Attachment 2: y_E_cal2.png
y_E_cal2.png
Fixede786s Wed Jun 12 18:11:04 2019 mugastOTHERSoftware Online Energy Calibration
Fixede786s Wed Jun 19 10:09:10 2019 mugastMUST2HardwareN/ATime calibrator cabled
range 640 ns
period 20 ns
Fixede786s Mon Jun 24 12:06:17 2019 mugastOFFLINEGeneralN/ABeam energy loss
Caculation with LISE++
Beam initial: 9.96 MeV/u
CATS 2 : 9.79
15 um ice water: 9.39
3.8 um Havar: 8.83
2.2 mm 3He (mid target): 8.24
2.2 mm 3He (full target): 7.61
3.8 um Havar : 6.99
15 um ice water: 6.50

with this we saw correctly both pp and pp' in MUST2:
Attachment 1: Kinepp.png
Kinepp.png
Fixede786s Mon Jun 24 21:42:11 2019 mugastRUNGeneralCryo-3HeBeam and cryo target
The beam is fluctuating between 18 kHz and 22 kHz in VAMOS (24 to 27 kHz in CATS1)
Division on CATS1 trigger is 1000
Division on VAMOS trigger is 1000 in the GMT.


The target is stable with 6.00 K temperature, P=700mbar
We fill 4He every 5 to 5:30 hours and we use more or less 5.5 cm (i.e. 35l) for each filling.
The next bottle change is foreseen on wednesday morning.

We had 2 crashes of the target acquisition this afternoon. We think that it is due to the temperature. We added a fan and we slow down the reading of the temperature to every 12s (instead of 10s).
Fixede786s Tue Jun 25 11:55:12 2019 mugastOFFLINEGeneralCryo-3HeHere is the F***G gs
We added the correct deformation of the target thickness, and corrected for it with the angle dependance.
15 um Water
Correct beam energy
Correct target position
Run 56 only
Attachment 1: Run56_better.pdf
Run56_better.pdf
Fixede786s Wed Jun 26 13:48:35 2019 mugastOFFLINEGeneralCryo-3Heanalysis
Attachment 1: Ekine_Ex_run56_58.png
Ekine_Ex_run56_58.png
Fixede786s Thu Jun 27 00:26:37 2019 mugastOFFLINEGeneral statistics until now
Maybe some stat still to recover from better gate and mass and Z reconstruction.

Andrea
Attachment 1: cqnvqs_.png
cqnvqs_.png
Fixede768s Fri Jul 12 12:07:56 2019 mugastOTHERGeneralN/AMasks for MUST2
Masks for MUST2 are now mounted.

NOTE: one mask is not properly screwed (top left) and should be mounted again on Monday morning when we open.

Masks cover theta_lab < 38 deg, corresponding to < 30 pps of 15O for 15O+19F elastic channel assuming 2e7 pps of 15O and 1.25 mg/cm2 of LiF.
Attachment 1: masks_MUST2.jpg
masks_MUST2.jpg
Attachment 2: masques_Must_pour_Mugast.png
masques_Must_pour_Mugast.png
Attachment 3: matrixImpact_shield_MM2.png
matrixImpact_shield_MM2.png
Fixed  Tue Jul 16 18:51:06 2019 mugastVAMOSGeneralLiF15N beam optimisation
Attachment 1: IMG_20190716_185112.jpg
IMG_20190716_185112.jpg
Attachment 2: run_55_target_thick_01_Vamos_11.png
run_55_target_thick_01_Vamos_11.png
Attachment 3: run_55_target_thick_01_Vamos_1.png
run_55_target_thick_01_Vamos_1.png
Fixede768s Tue Jul 16 19:21:19 2019 mugastOTHERGeneral Qpole values
Brho = 0.640 Tm

RMN = 3247,742 Gaus (215.630 A)

Q31 = 18.5 A
Q32 = 20.9 A
Q41 = 170.579 A
Q42 = 150.829 A
Fixede768s Tue Jul 16 22:25:51 2019 mugastOTHERGeneral Oxygen 15 decay scheme
beta+ decay to the ground state of 15N
gammas @ 511 keV
Attachment 1: 15O_decay_scheme.png
15O_decay_scheme.png
Fixede768s Wed Jul 17 01:08:03 2019 mugastVAMOSGeneralLiFnew beam settings
The last values Q32=21.0, Q31=22.8
With these new optimzed values, we have:
Std dev-x=6.147
Std dev y=13.29

Beam intensity=10&#8308; pps, no masque mobile
Attachment 1: run_60_target_thick_01_Vamos.png
run_60_target_thick_01_Vamos.png
Fixede768s Wed Jul 17 01:42:46 2019 mugastVAMOSGeneralLiFBeam intensity versus Trigger Vamos
Masque mobile at +7 mm

Beam: 10^5 pps, Fag:10, Trigger VAMOS:10
Beam: 8.10^5 pps, Fag:15, Trigger VAMOS:15
Beam: 10^7 pps, Fag:241, Trigger VAMOS:271

ELOG Home Page