Fixed, e744s, Sun Apr 14 23:41:32 2019, Valerian, Simon and Belen, OFFLINE, Software, CH2, Preliminary results for 2p Ecm2p.pngfirst_proton_second_proton.png
Preliminary results using runs 122 : O 1 2 3 4
Fixed, e744s, Mon Apr 15 12:15:22 2019, Valerian and Sylvain, OFFLINE, Software, CH2, Kinematic line 2p ELabThetaLab_new.pngEcm2p_new.png
 
Fixed, e744s, Mon Apr 15 17:05:24 2019, Valerian, OFFLINE, Software, CH2, Evolution of deE DeEEvolutionWithIntensity.png
Evolution of dEE between run 122 (8e4pps) and 129 (2.5e5pps)
Fixed, e744s, Mon Apr 15 17:10:54 2019, Valerian, OFFLINE, Software, CH2, Evolution of deE DeEEvolutionWithIntensityIC1vsIC2.png
Evolution of dEE between run 122 (8e4pps) and 130 (2.5e5pps)
Fixed, e744s, Tue Apr 16 11:39:40 2019, Valerian, OFFLINE, Software, CH2, two proton kinematics and center of mass reconstruction with all stat All_stat_2p.png
 
Fixed, e744s, Tue Apr 16 21:48:31 2019, Valerian, Belen, Sylvain, Iulian, Simon and Blaise-Mael, OFFLINE, Software, CH2, Preliminary Dalitz plot Dalitz_2p.pngDalitz_zoom2p.pngDalitz_2pcol.png
 
Fixed, e744s, Tue Apr 16 23:38:04 2019, Fairouz Jaromir, RUN, Software, , Script to watch efficiency CATS and VAMOS offline hour by hour EffCheck_fhjm.C
do

lpcgrit
Fixed, e744s, Wed Apr 17 07:04:24 2019, Valerian (Mariluz was the one in charge of AGATA), AGATA, Software, CH2, Cristal 4A stopped 
Cristal 4A was stopped during the night, see AGATA logbook for more details.
Fixed, e744s, Wed Apr 17 09:15:28 2019, Valerian, Iulian, MUST2, Software, N/A, HV off end of exp e744 
[CODE]  **** HVMUST2 connected to crate at IP : 172.16.139.10 ****
 **** HVMUST2 loading crate map: found 16 slots  ****
 **** HVVAMOS connected to crate at IP : 172.16.137.110 ****
Fixed, e744s, Wed Apr 17 13:48:25 2019, Valerian and Diego, RUN, Software, CH2, New Dalitz plot with good angles in vamos DalitzGoodAngle.png
The previous Dalitz plot was wrong as I was using the angle from vamos as polar angles.
Now that it is corrected we see that this decay seems sequential.
Fixed, e744s, Fri Apr 26 11:29:02 2019, Valerian, OTHER, Software, N/A, Notes about the electronic Signal_oscilloscope_coinc_module.jpeg
While doing the electronic scheme, I saw that the Inspection line was inducing a bad signal in the coincidence module between fag and CATS1. See joined
image.
Fixed, e786s, Wed Jun 12 17:59:01 2019, mugast, OTHER, Software, , Online Energy Calibration x_E_cal.pngy_E_cal2.png
Updated Online Energy calibration for MUGAST, based on run_0231 data
    Fixed, e786s, Wed Jun 12 18:11:04 2019, mugast, OTHER, Software, , Online Energy Calibration 
 
    Fixed, e786s, Fri Jun 21 15:15:08 2019, OttoTime, OTHER, Software, N/A, TimeCalibrationSuccessful time_cal_must2.pngtime_cal_mugast.png
[quote="OttoTime"]*** Run Time Calibrator FSC ***
  - Run: 242
  - MUVI: MUVI3
Fixed, e786s, Mon Jun 24 01:52:00 2019, Louis, OFFLINE, Software, Cryo-3He, Procedure to convert and calibrate runs 

Here is the updated procedure to convert a run, with VAMOS data.
Fixed, e786s, Mon Jun 24 16:50:48 2019, Valerian and Adrien, OFFLINE, Software, Cryo-3He, 3He-d kinematics Kine47K.png
To plot those kinematics, there is a macros called kine.cxx

The first plot correspond to the Silicon energy in MUGAST corrected for energy loss (some improvement might be needed)
Fixed, e768s, Mon Jul 22 11:21:25 2019, mugast, MUST2, Software, , Pedestals of MG3 run_125_impactMG.pngrun_125_MG3X.png
Pedestals of MG3_X have changed yesterday, they are back to about 8200 as they should be --> saved in ped_muvi2sec2_22072019_new
We are using wrong pedestals (of about 9600) --> the pedestals are saved under mugast account as ped_muvi2_sec2_22072019_sameas_1807219
Pinned, e775s, Thu Feb 27 12:44:37 2020, Nicolas, OFFLINE, Software, , How to produce control spectra 
In /home/mugast/analysis/nptool/Projects/MUGAST/e775s directory there is the Control.C macro which draws: Ex, Ex vs Eg and Elab vs thetalab for each run
(run number must be given in argument) or for chained runs (argument must be 0)
    Pinned, e775s, Thu Feb 27 16:35:26 2020, Nicolas, OFFLINE, Software, , How to produce control spectra 
[quote="Nicolas"]In /home/mugast/analysis/nptool/Projects/MUGAST/e775s directory there is the Control.C macro which draws: Ex, Ex vs Eg and Elab vs thetalab
for each run (run number must be given in argument) or for chained runs (argument must be 0)[/quote]
Ongoing, e775s, Sat Feb 29 10:34:31 2020, mugast ; valerian irene, OFFLINE, Software, CD2-Au, Issues in the EX reconstruction Comparison_all_and_best_detector.pngKinematics_for_each_detectors.pdfExvsTheta_each_detectors.pdfMUGAST_3D.pdf
We are currently working on the EX reconstruction which is off for detector 1, 3 and 7... One of our guess might be that there is an issue with the position
of the detectors which gives error in theta... As the energy calibration is ok. Joined are :