Fixede768s Fri Jul 19 09:38:05 2019 mugastGRITGeneralLiFImpact matrix for MUGAST
Attachment 1: mugast_missing_strip.png
mugast_missing_strip.png
Fixede768s Fri Jul 19 10:35:05 2019 OttoRunRUNGeneralLiFRun113
*************************
Run : 113
*************************

Start at 2019-07-19 10:35:00.811685

JUNK

Stop at 2019-07-19 10:42:58.694755
Stop comment: type your message here

Stop at 2019-07-19 10:51:03.268053
Stop comment: type your message here
Fixede768s Fri Jul 19 12:06:44 2019 OttoRunRUNGeneralLiFRun115
*************************
Run : 115
*************************

Start at 2019-07-19 10:53:00.945262

same conditions as before
LiF target
Brho=0556

GMT triggers :
MG
Square
MM
Vamos div
Baf2 div

Beam optimization during this run to try to improve intensity
Attachment 1: run_115_scaler1.png
run_115_scaler1.png
Attachment 2: run_115_IC_IC.png
run_115_IC_IC.png
Attachment 3: run_115_REC.png
run_115_REC.png
Attachment 4: run_115_TAC.png
run_115_TAC.png
Attachment 5: run_115_IC2.png
run_115_IC2.png
Attachment 6: run_115_IC.png
run_115_IC.png
Attachment 7: run_115_Ewire.png
run_115_Ewire.png
Attachment 8: run_115_DCY.png
run_115_DCY.png
Attachment 9: run_115_DCXpng.png
run_115_DCXpng.png
Attachment 10: run_115_MM_MG_ERaw.png
run_115_MM_MG_ERaw.png
Attachment 11: run_115_Tac.png
run_115_Tac.png
Attachment 12: run_115_MG_ToF.png
run_115_MG_ToF.png
Attachment 13: run_115_MM_DeE.png
run_115_MM_DeE.png
Attachment 14: run_115_MM_Tof.png
run_115_MM_Tof.png
Attachment 15: run_115_MG_impact.png
run_115_MG_impact.png
Attachment 16: run_115_MM_impact.png
run_115_MM_impact.png
Attachment 17: run_115_scaler2.png
run_115_scaler2.png
Fixede768s Fri Jul 19 13:09:14 2019 mugastBEAMGeneralLiFCounting rates as a function of beam intensity
checking counting rates as a function of increasing beam intensity
Attachment 1: IMG_20190719_130411.jpg
IMG_20190719_130411.jpg
Fixede768s Fri Jul 19 13:24:01 2019 mugastOFFLINEGeneralLiFg-ray spectrum (run 112) requiring 19Ne in VAMOS
Attachment 1: 21.png
21.png
Fixede768s Fri Jul 19 14:44:30 2019 adrienOTHERHardwareLiFThe diamond detector is not behaving properly
On the image attached we can see the counting rate of the diamond (Red) going up linearly while Vamos (blue) staty stables.
This is understood as the diamond's graphite impurities charging up with the beam, so the baseline is moving up and we trigger more and more on noise. At some point I expect the counting rate to start dropping as the detector is no longer polarized.
Attachment 1: dimaond_is_not_working.png
dimaond_is_not_working.png
Fixede768s Fri Jul 19 15:11:10 2019 mugastOFFLINEGeneral Procedure for run conversion and analysis
Here is the procedure to convert a run with VAMOS and AGATA data and add those data to the Kinematic plot.

Every 4GB there will be a file change, to see if there is a file change type:

ls -ltrh /data/mugastX/e768s/acquisition/run/

Convert the last 4GB file and add it to the chain through the following steps:

Open a terminal from one of the Mugast computer:
Type: source $HOME/GoToVamosAna
Type: MyVAna -d2Ar -f /data/mugastX/e768s/acquisition/run/run_$$$$-DD-MM-YY.HHhMMmSSs /data/mugastX/e768s/acquisition/run/RootA/r$$$$_000a.root

OR (in case the run is split in more files)

Type: MyVAna -d2Ar -f /data/mugastX/e768s/acquisition/run/run_$$$$-DD-MM-YY.HHhMMmSSs.N /data/mugastX/e768s/acquisition/run/RootA/r$$$$_00Na.root

(If you get the error "Could not find the BrhoRef for the run <RunNr> ", update the ./Calibs/ListBrho.dat file with relevant Brho for RunNr)

Now you would be already able to run npanalysis to analyze the data VAMOS+Mugast with the following procedure:

Type: exit (to exit the VAMOS environment)
Type: lpcgrit (to load the analysis environment)
Type: npp MUGAST
Edit the exe_e768s.sh to specify which runs to analyze. The command should be the following:

npanalysis -D mugast.detector -C Calibration.txt -E ./Reaction/15N7Lit.reaction -T /data/mugastX/e768s/acquisition/run/RootA/r$$$$_00Na.root AD -O run_$$$$_N.root

Type: ./exe_e768s.sh

To convert a run including the AGATA data, the procedure is the following:
Go to the AGATA analysis computer (last on the right close to the window in the acquisition room), open a terminal and type the following commands:

> a4
> t e768s
> cd Replay
>./do_global_replay.sh -run ## (## is the number of the run you want to convert).

When it is finished, copy the root file to the GANIL world:

> mkdir /dataganil/e768s/acquisition/root_agata/run_00##/
> cp ./run_00##/Out/Analysis/Tree_00*.root /dataganil/e768s/acquisition/root_agata/run_00##/.

Now you can analyze the file using npanalysis.
The command in the exe_e768s.sh file should now look like:

npanalysis -D mugast.detector -C Calibration.txt -E ./Reaction/15N7Lit.reaction -T /data/mugastX/e768s/acquisition/root_agata/run_00##/Tree_000N.root TreeMaster -O run_00##_N_agata.root

The run will be created in the ./NPOutputs folder.
Bon courage!
Fixede768s Fri Jul 19 15:15:47 2019 Diego RamosOFFLINEGeneralLiF19Ne identification in VAMOS together with MUGAST
Attachment 1: VAMOS_MUGAST_IDENTIFICATION.png
VAMOS_MUGAST_IDENTIFICATION.png
Fixede768s Fri Jul 19 15:18:38 2019 Diego RamosOFFLINEGeneralLiFPosition of 19Ne in dE:E in VAMOS
Conclusion: IC pressure not needed to be reduced.
Attachment 1: Position_Of_19Ne_In_dEE.png
Position_Of_19Ne_In_dEE.png
Fixede768s Fri Jul 19 15:55:38 2019 mugastRUNGeneral Beam is fluctuating
Run 115 stopped at 16h40.
Attachment 1: VAMOS_MUGAST_IDENTIFICATION1.png
VAMOS_MUGAST_IDENTIFICATION1.png
Attachment 2: run_115_scaler3.png
run_115_scaler3.png
Attachment 3: run_115_scaler2.png
run_115_scaler2.png
Attachment 4: run_115_scaler1.png
run_115_scaler1.png
Attachment 5: run_115_IC_IC.png
run_115_IC_IC.png
Attachment 6: run_115_REC.png
run_115_REC.png
Attachment 7: run_115_TAC.png
run_115_TAC.png
Attachment 8: run_115_IC2.png
run_115_IC2.png
Attachment 9: run_115_IC.png
run_115_IC.png
Attachment 10: run_115_Ewire.png
run_115_Ewire.png
Attachment 11: run_115_DCY.png
run_115_DCY.png
Attachment 12: run_115_DCXpng.png
run_115_DCXpng.png
Attachment 13: run_115_MM_MG_ERaw.png
run_115_MM_MG_ERaw.png
Attachment 14: run_115_Tac.png
run_115_Tac.png
Attachment 15: run_115_MG_ToF.png
run_115_MG_ToF.png
Attachment 16: run_115_MM_DeE.png
run_115_MM_DeE.png
Attachment 17: run_115_MM_Tof.png
run_115_MM_Tof.png
Attachment 18: run_115_MG_impact.png
run_115_MG_impact.png
Attachment 19: run_115_MM_impact.png
run_115_MM_impact.png
Fixede768s Fri Jul 19 16:43:08 2019 OttoRunRUNGeneralLiFRun116
*************************
Run : 116
*************************

Start at 2019-07-19 16:42:58.163547

Stop at 2019-07-20 04:34:58.716855
Stop comment: type your message here

Stop at 2019-07-20 10:40:22.875934
Stop comment: loss beam, premary beam monitor
Fixede768s Fri Jul 19 17:15:46 2019 mugastRUNGeneralLiFRun 116
Attachment 1: run116-Scaler2.png
run116-Scaler2.png
Fixede768s Fri Jul 19 17:33:21 2019 NicolasOTHERGeneral AGATA: what if a crystal status get red
1. Go to the AGATA Digitizer: Control tab of the browser
2. Select the detector and crystal, then click 'Select'
3. Click the 'ReSync Current Digitizer Optical Link'

Normally it should go green again, otherwise call AGATA people
Fixede768s Fri Jul 19 17:52:24 2019 NicolasOTHERGeneral AGATA: replaying runs
1. Go to the AGATA analysis computer, open a terminal and execute the following commands:
> a4
> t e768s
> cd Replay
> ./do_global_replay.sh -run ### (### is the run number you want to convert)
if it complains that the folder with the run already exists, just > rm -rf runXXXX/ (where XXXX is the run you're replaying) in the Replay folder

2. When it is finished copy the root file to the GANIL world:
> mkdir /dataganil/e768s/acquisition/root_agata/run_0###
> cp ./run_0###/Out/Analysis/Tree_00*.root /dataganil/e768s/acquisition/run_0###
Fixede768s Fri Jul 19 18:57:12 2019 mugastONLINEGeneralLiFscreenshots run 116
Attachment 1: Diamond_VAMOS_run116_3.png
Diamond_VAMOS_run116_3.png
Attachment 2: Scalers_run116_3.png
Scalers_run116_3.png
Attachment 3: IC_run116_3.png
IC_run116_3.png
Attachment 4: PF_run116_3.png
PF_run116_3.png
Attachment 5: T_MUGAST_VAMOS_run116_3.png
T_MUGAST_VAMOS_run116_3.png
Attachment 6: ID1d_run116_3.png
ID1d_run116_3.png
Attachment 7: MW_run116_3.png
MW_run116_3.png
Attachment 8: Ewire_run116_3.png
Ewire_run116_3.png
Attachment 9: Twire_run116_3.png
Twire_run116_3.png
Attachment 10: SumDC_run116_3.png
SumDC_run116_3.png
Attachment 11: MM_MG_Eraw_run116_3.png
MM_MG_Eraw_run116_3.png
Attachment 12: MM_ETOF_run116_3.png
MM_ETOF_run116_3.png
Attachment 13: MG_ETOF_run116_3.png
MG_ETOF_run116_3.png
Attachment 14: MM_EDE_run116_3.png
MM_EDE_run116_3.png
Attachment 15: TAC_run116_3.png
TAC_run116_3.png
Attachment 16: MM_Impact_run116_3.png
MM_Impact_run116_3.png
Attachment 17: MG_Impact_run116_3.png
MG_Impact_run116_3.png
Fixede768s Fri Jul 19 21:43:35 2019 Franck & FaïrouzRUNGeneralLiFscreenshots run 116 @ 21h30
Attachment 1: T_MUGAST_VAMOS_run116_4.png
T_MUGAST_VAMOS_run116_4.png
Attachment 2: IC_run116_4.png
IC_run116_4.png
Attachment 3: DC_X_run116_4.png
DC_X_run116_4.png
Attachment 4: DC_Y_run116_4.png
DC_Y_run116_4.png
Attachment 5: DC_E_run116_4.png
DC_E_run116_4.png
Attachment 6: MW_run116_4.png
MW_run116_4.png
Attachment 7: PF_run116_4.png
PF_run116_4.png
Attachment 8: MM_MG_Eraw_run116_4.png
MM_MG_Eraw_run116_4.png
Attachment 9: MM_MG_Traw_run116_4.png
MM_MG_Traw_run116_4.png
Attachment 10: Correlation_run116_4.png
Correlation_run116_4.png
Attachment 11: TAC_run116_4.png
TAC_run116_4.png
Attachment 12: MG_ETOF_run116_4.png
MG_ETOF_run116_4.png
Attachment 13: MM_EDE_run116_4.png
MM_EDE_run116_4.png
Attachment 14: MM_ETOF_run116_4.png
MM_ETOF_run116_4.png
Attachment 15: MG_Impact_run116_4.png
MG_Impact_run116_4.png
Attachment 16: MM_Impact_run116_4.png
MM_Impact_run116_4.png
Attachment 17: Scalers_run116_4.png
Scalers_run116_4.png
Fixede768s Fri Jul 19 22:16:43 2019 mugastONLINEGeneralN/AHow to restart the vamos spectrum visualization (on the mugast daq computer)
On the mugast DAQ computer:

* Open a terminal
* Type "GoToVamosAna"
* Type "vigru"
* In vigru: File, Open config -> vigru_ganp154.xml
* Then: Setup, Sources, Host/FileName: "ganp154", port:9090

If a spectrum is missing -> Add it with "display one histo"
Fixede768s Fri Jul 19 23:10:18 2019 FrancoRUNGeneral3-alphaRun302
Added energy calibration for square detector (MG 10).


OttoRun wrote:
*************************
Run : 302
*************************

Start at 2019-07-11 16:54:22.512184

3 alpha calibration run
+ without MM2 masks
+ suppressed pedestals

Square detectors:
+ MG10: all X strips masked; mate 14 & 16 masked
+ MG9: all X & Y strips masked

Stop at 2019-07-12 05:44:35.805449
Stop comment:
Attachment 1: run302_MG_Ecal.png
run302_MG_Ecal.png
Fixede768s Fri Jul 19 23:12:36 2019 FrancoRUNGeneral3-alphaRun302
Added energy calibration for square detector (MG 10).


Franco wrote:
Attached the calibrated spectra for MUST2 and Mugast for run 302 (no pedestals).


OttoRun wrote:
*************************
Run : 302
*************************

Start at 2019-07-11 16:54:22.512184

3 alpha calibration run
+ without MM2 masks
+ suppressed pedestals

Square detectors:
+ MG10: all X strips masked; mate 14 & 16 masked
+ MG9: all X & Y strips masked

Stop at 2019-07-12 05:44:35.805449
Stop comment:
Attachment 1: run302_MG_Ecal.png
run302_MG_Ecal.png
Fixede768s Sat Jul 20 00:01:27 2019 Franck & FaïrouzRUNGeneralLiFscreenshots run 116 @ 00h00
Algeria won Africa nations cup!!! Happy
Attachment 1: Scaler_run116_5.png
Scaler_run116_5.png
Attachment 2: IC-IC_run116_6.png
IC-IC_run116_6.png
Attachment 3: PF_run116_5.png
PF_run116_5.png
Attachment 4: T_MUGAST_VAMOS_run116_5.png
T_MUGAST_VAMOS_run116_5.png
Attachment 5: IC_run116_5.png
IC_run116_5.png
Attachment 6: MW_run116_5.png
MW_run116_5.png
Attachment 7: DC_E_run116_5.png
DC_E_run116_5.png
Attachment 8: DC_Y_run116_5.png
DC_Y_run116_5.png
Attachment 9: DC_X_run116_5.png
DC_X_run116_5.png
Attachment 10: Timecalibration_run116_5.png
Timecalibration_run116_5.png
Attachment 11: MM_MG_Traw_run116_5.png
MM_MG_Traw_run116_5.png
Attachment 12: MM_MG_Eraw_run116_5.png
MM_MG_Eraw_run116_5.png
Attachment 13: Correlation_run116_5.png
Correlation_run116_5.png
Attachment 14: TAC_run116_5.png
TAC_run116_5.png
Attachment 15: MG_ETOF_run116_5.png
MG_ETOF_run116_5.png
Attachment 16: MM_EDE_run116_5.png
MM_EDE_run116_5.png
Attachment 17: MM_ETOF_run116_5.png
MM_ETOF_run116_5.png
Attachment 18: MM_Impact_run116_5.png
MM_Impact_run116_5.png
Attachment 19: MG_Impact_run116_5.png
MG_Impact_run116_5.png

ELOG Home Page