Fixed, e768s, Fri Jul 19 09:38:05 2019, mugast, GRIT, General, LiF, Impact matrix for MUGAST mugast_missing_strip.png
 
Fixed, e768s, Fri Jul 19 10:35:05 2019, OttoRun, RUN, General, LiF, Run113 
*************************
  [SIZE=3][B]Run  : 113[/B][/SIZE]
*************************
Fixed, e768s, Fri Jul 19 12:06:44 2019, OttoRun, RUN, General, LiF, Run115 17x
*************************
  [SIZE=3][B]Run  : 115[/B][/SIZE]
*************************
Fixed, e768s, Fri Jul 19 13:09:14 2019, mugast, BEAM, General, LiF, Counting rates as a function of beam intensity IMG_20190719_130411.jpg
checking counting rates as a function of increasing beam intensity
Fixed, e768s, Fri Jul 19 13:24:01 2019, mugast, OFFLINE, General, LiF, g-ray spectrum (run 112) requiring 19Ne in VAMOS 21.png
 
Fixed, e768s, Fri Jul 19 14:44:30 2019, adrien, OTHER, Hardware, LiF, The diamond detector is not behaving properly dimaond_is_not_working.png
On the image attached we can see the counting rate of the diamond (Red) going up linearly while Vamos (blue) staty stables.
This is understood as the diamond's graphite impurities charging up with the beam, so the baseline is moving up and we trigger more and more on noise.
At some point I expect the counting rate to start dropping as the detector is no longer polarized.
Fixed, e768s, Fri Jul 19 15:11:10 2019, mugast, OFFLINE, General, , Procedure for run conversion and analysis 
Here is the procedure to convert a run with VAMOS and AGATA data and add those data to the Kinematic plot.

Every 4GB there will be a file change, to see if there is a file change type:
Fixed, e768s, Fri Jul 19 15:15:47 2019, Diego Ramos, OFFLINE, General, LiF, 19Ne identification in VAMOS together with MUGAST VAMOS_MUGAST_IDENTIFICATION.png
 
Fixed, e768s, Fri Jul 19 15:18:38 2019, Diego Ramos, OFFLINE, General, LiF, Position of 19Ne in dE:E in VAMOS Position_Of_19Ne_In_dEE.png
Conclusion: IC pressure not needed to be reduced.
Fixed, e768s, Fri Jul 19 15:55:38 2019, mugast, RUN, General, , Beam is fluctuating 19x
Run 115 stopped at 16h40.  
Fixed, e768s, Fri Jul 19 16:43:08 2019, OttoRun, RUN, General, LiF, Run116 
*************************
  [SIZE=3][B]Run  : 116[/B][/SIZE]
*************************
Fixed, e768s, Fri Jul 19 17:15:46 2019, mugast, RUN, General, LiF, Run 116 run116-Scaler2.png
 
Fixed, e768s, Fri Jul 19 17:33:21 2019, Nicolas, OTHER, General, , AGATA: what if a crystal status get red 
1. Go to the AGATA Digitizer: Control tab of the browser
2. Select the detector and crystal, then click 'Select'
3. Click the 'ReSync Current Digitizer Optical Link'
Fixed, e768s, Fri Jul 19 17:52:24 2019, Nicolas, OTHER, General, , AGATA: replaying runs 
1. Go to the AGATA analysis computer, open a terminal and execute the following commands:
> a4
> t e768s
Fixed, e768s, Fri Jul 19 18:57:12 2019, mugast, ONLINE, General, LiF, screenshots run 116 17x
 
Fixed, e768s, Fri Jul 19 21:43:35 2019, Franck & Faïrouz, RUN, General, LiF, screenshots run 116 @ 21h30 17x
 
Fixed, e768s, Fri Jul 19 22:16:43 2019, mugast, ONLINE, General, N/A, How to restart the vamos spectrum visualization (on the mugast daq computer) 
On the mugast DAQ computer:

* Open a terminal
    Fixed, e768s, Fri Jul 19 23:10:18 2019, Franco, RUN, General, 3-alpha, Run302 run302_MG_Ecal.png
Added energy calibration for square detector (MG 10).

[quote="OttoRun"]*************************
    Fixed, e768s, Fri Jul 19 23:12:36 2019, Franco, RUN, General, 3-alpha, Run302 run302_MG_Ecal.png
Added energy calibration for square detector (MG 10).

[quote="Franco"]Attached the calibrated spectra for MUST2 and Mugast for run 302 (no pedestals).
Fixed, e768s, Sat Jul 20 00:01:27 2019, Franck & Faïrouz, RUN, General, LiF, screenshots run 116 @ 00h00 19x