  MUGAST, Page 31 of 132  Not logged in MUGAST
Status ExpNbrdown Date Author Type Category Target-Source Subject Text Attachments
Fixede768s Fri Jul 19 09:38:05 2019 mugastGRITGeneralLiFImpact matrix for MUGAST   mugast_missing_strip.png 
Fixede768s Fri Jul 19 10:35:05 2019 OttoRunRUNGeneralLiFRun113*************************
  [SIZE=3][B]Run  : 113[/B][/SIZE]
*************************
  
Fixede768s Fri Jul 19 12:06:44 2019 OttoRunRUNGeneralLiFRun115*************************
  [SIZE=3][B]Run  : 115[/B][/SIZE]
*************************
 17x 
Fixede768s Fri Jul 19 13:09:14 2019 mugastBEAMGeneralLiFCounting rates as a function of beam intensitychecking counting rates as a function of increasing
beam intensity
 IMG_20190719_130411.jpg 
Fixede768s Fri Jul 19 13:24:01 2019 mugastOFFLINEGeneralLiFg-ray spectrum (run 112) requiring 19Ne in VAMOS   21.png 
Fixede768s Fri Jul 19 14:44:30 2019 adrienOTHERHardwareLiFThe diamond detector is not behaving properlyOn the image attached we can see the counting
rate of the diamond (Red) going up linearly
while Vamos (blue) staty stables.
 dimaond_is_not_working.png 
Fixede768s Fri Jul 19 15:11:10 2019 mugastOFFLINEGeneral Procedure for run conversion and analysisHere is the procedure to convert a run with
VAMOS and AGATA data and add those data to
the Kinematic plot.
  
Fixede768s Fri Jul 19 15:15:47 2019 Diego RamosOFFLINEGeneralLiF19Ne identification in VAMOS together with MUGAST   VAMOS_MUGAST_IDENTIFICATION.png 
Fixede768s Fri Jul 19 15:18:38 2019 Diego RamosOFFLINEGeneralLiFPosition of 19Ne in dE:E in VAMOSConclusion: IC pressure not needed to be reduced.  Position_Of_19Ne_In_dEE.png 
Fixede768s Fri Jul 19 15:55:38 2019 mugastRUNGeneral Beam is fluctuatingRun 115 stopped at 16h40.    19x 
Fixede768s Fri Jul 19 16:43:08 2019 OttoRunRUNGeneralLiFRun116*************************
  [SIZE=3][B]Run  : 116[/B][/SIZE]
*************************
  
Fixede768s Fri Jul 19 17:15:46 2019 mugastRUNGeneralLiFRun 116   run116-Scaler2.png 
Fixede768s Fri Jul 19 17:33:21 2019 NicolasOTHERGeneral AGATA: what if a crystal status get red1. Go to the AGATA Digitizer: Control tab
of the browser
2. Select the detector and crystal, then
  
Fixede768s Fri Jul 19 17:52:24 2019 NicolasOTHERGeneral AGATA: replaying runs1. Go to the AGATA analysis computer, open
a terminal and execute the following commands:
> a4
  
Fixede768s Fri Jul 19 18:57:12 2019 mugastONLINEGeneralLiFscreenshots run 116   17x 
Fixede768s Fri Jul 19 21:43:35 2019 Franck & FaïrouzRUNGeneralLiFscreenshots run 116 @ 21h30   17x 
Fixede768s Fri Jul 19 22:16:43 2019 mugastONLINEGeneralN/AHow to restart the vamos spectrum visualization (on the mugast daq computer)On the mugast DAQ computer:

* Open a terminal
  
Fixede768s Fri Jul 19 23:10:18 2019 FrancoRUNGeneral3-alphaRun302Added energy calibration for square detector
(MG 10).
 run302_MG_Ecal.png 
Fixede768s Fri Jul 19 23:12:36 2019 FrancoRUNGeneral3-alphaRun302Added energy calibration for square detector
(MG 10).
 run302_MG_Ecal.png 
Fixede768s Sat Jul 20 00:01:27 2019 Franck & FaïrouzRUNGeneralLiFscreenshots run 116 @ 00h00Algeria won Africa nations cup!!! :-))  19x 