Fixed
TEST
Tue Mar 5 18:03:24 2019
iulian Marlene
MUST2
Software
N/A
Calimero problem on Y side
Calimero not working properly on Y side of
any mm detector
Fixed
TEST
Tue Mar 5 18:18:46 2019
iulian Marlene
MUST2
Hardware
3-alpha
run 97 3a run Muvi3 night run
Run 87
stop@ 5:42 am
Fixed
TEST
Wed Mar 6 15:02:51 2019
Valerian
MUST2
Hardware
3-alpha
Cooling temperature is relevant for the resolution
Using run 52 -> 13deg and run 87 -> -5deg.
We see that the resolution improves at -5
Fixed
TEST
Thu Mar 7 09:29:47 2019
Marlene
GRIT
General
run 96 double alpha source run shifted 60mm
RUN 96
double alpha source
Fixed
TEST
Thu Mar 7 14:02:03 2019
Marlène Iulian
MUST2
General
N/A
test of MUST2 electronics
Test with pulser at 20 kHz
The OR of MUVI was scaled down by a factor
of 100, to provoke some resets
Fixed
Tue Mar 12 10:21:17 2019
Marlène
MUST2
General
Debug Calimero Y
Debug of Calimero
test of channels (mate) masking : OK with
Fixed
TEST
Mon Mar 18 18:31:18 2019
valerian marlène
GRIT
General
3-alpha
RUN 20 (com2019) 3 alpha overnight
RUN20
Run with double 3alpha source MUST2+MG1_7+MG11
Fixed
Tue Mar 19 19:35:53 2019
marlene
GRIT
General
RUN 98 3alpha source all detectors
RUN 98
3 alpha source
all detectors (trap,square, MUST2,annular)
Fixed
TEST
Thu Mar 21 10:37:47 2019
Adrien and Valerian
MUST2
General
N/A
Test TOF must2
To make sure the mate work correctly we took
an alpha run with a delayed fag on the MUVI
stop:
Fixed
TEST
Thu Mar 21 13:28:06 2019
Valerian and Adrien
DAQ
Software
N/A
First fully functionnal time calibration run on X and Y of MG1
Our program is able to perform the time calibration
of our detector for both X and Y, see picture
attached.
Fixed
TEST
Fri Mar 22 17:28:09 2019
Otto
RUN
General
N/A
TimeCalibratorRun
*** Run Time Calibrator FSC ***
- Run: 117
- MUVI: MUVI1
Fixed
TEST
Fri Mar 22 17:37:37 2019
Otto
RUN
General
N/A
TimeCalibratorRun
*** Run Time Calibrator FSC ***
- Run: 118
- MUVI: MUVI1
Fixed
TEST
Fri Mar 22 17:47:04 2019
Otto
RUN
General
N/A
TimeCalibratorRun
*** Run Time Calibrator FSC ***
- Run: 119
- MUVI: MUVI2
Fixed
TEST
Fri Mar 22 17:56:37 2019
Otto
RUN
General
N/A
TimeCalibratorRun
*** Run Time Calibrator FSC ***
- Run: 120
- MUVI: MUVI2
Fixed
TEST
Fri Mar 22 18:06:11 2019
Otto
RUN
General
N/A
TimeCalibratorRun
*** Run Time Calibrator FSC ***
- Run: 121
- MUVI: MUVI3
Fixed
TEST
Fri Mar 22 18:15:39 2019
Otto
RUN
General
N/A
TimeCalibratorRun
*** Run Time Calibrator FSC ***
- Run: 122
- MUVI: MUVI3
Fixed
TEST
Sat Mar 23 15:26:06 2019
Adrien Matta
OTHER
Software
N/A
To do list
[SIZE=2][B]FSC:[/B][/SIZE]
[LIST][COLOR=orange]
[*] Autoconf programme to set all regular
Fixed
TEST
Wed Mar 27 11:06:33 2019
Valerian and Cyril
GRIT
Hardware
3-alpha
Evolution of resolution with temperature
For the mugast telescope, changing the temperature
from 13deg to minus 4deg doesn't seem to
have an impact as strong as for the MUST2
Fixed
TEST
Thu Mar 28 14:22:25 2019
OttoRun
RUN
General
N/A
TEST
[SIZE=5][B] Run : 146[/B][/SIZE]
[SIZE=4] [B] Date : 28/03/2019[/B]
Fixed
TEST
Thu Mar 28 15:39:01 2019
Valerian
OFFLINE
Software
N/A
Status of the converion with VAMOS program
The conversion with VAMOS program was validated
using run_0020 from com2019