Ongoing, e793s, Wed Mar 3 17:12:57 2021, Franco, S1, Hardware, N/A, Schema of the new S1 S1.PNG
The signals of the new S1 will be splitted among 6 Mugast boards, according to the scheme attached.
The HV for the S1 have been updated accordingly, with labels like MG11/CsIMGXX.
Fixed, e793s, Wed Mar 3 17:18:42 2021, Franco, GRIT, General, N/A, MUVI's scheme and connections on the chamber connections_chamber_MUGAST.pngMUVI.PNG
Fixed, e793s, Fri Mar 5 16:14:21 2021, OttoRun, RUN, General, 3-alpha, Run618 MGRAWEY.pngMGRAWEX.pngMMRAWEY.pngMMRAWEX.png
*************************
Run : 618
*************************

Start at 2021-03-05 16:13:37.198228

run 3 alpha with pedestal and mugast DAQ
Fixed, e793s, Fri Mar 5 16:16:28 2021, mugast, DAQ, Software, , Pedestals for E793S 12x
Pedestal alignment was performed for Energy qnd Time for all cards with cooling at 0°.
The values are attached here and saved in : cd ganacq_manip/mugast/das-save/pedestal-save/pedestal_5march2021_15h54/
Fixed, e793s, Fri Mar 5 16:31:08 2021, OttoRun, RUN, General, 3-alpha, Run619 
*************************
Run :619
*************************

Start at 2021-03-05 16:30:39.722907

run 3 alpha without pedestals for MG but with pedestals for MM
Fixed, e793s, Fri Mar 5 16:39:08 2021, OttoRun, RUN, General, 3-alpha, Run620 
*************************
Run : 620
*************************

Start at 2021-03-05 16:38:16.476202

run 3 alpha without pedestal for all detectors, to be used for experiment

Stop at 2021-03-05 16:56:13.657279
Stop comment: type your message here

Stop at 2021-03-05 16:56:14.690583
Stop comment: type your message here

Stop at 2021-03-05 16:56:15.050212
Stop comment: type your message here

Stop at 2021-03-05 16:56:16.082040
Stop comment:

Stop at 2021-03-05 17:13:59.790265
Stop comment:

Stop at 2021-03-05 17:15:58.879697
Stop comment:

Stop at 2021-03-06 13:25:23.248954
Stop comment:

Stop at 2021-03-06 13:25:23.504734
Stop comment:

Stop at 2021-03-06 13:25:23.873972
Stop comment:
Fixed, e793s, Fri Mar 5 16:50:55 2021, OttoTime, RUN, General, N/A, TimeCalibratorRun 
*** Run Time Calibrator FSC ***
- Run: 622
- MUVI: MUVI1
- Side : MUFEE X (Junction)
- Telescope: 1, 2, 3, 4
Fixed, e793s, Fri Mar 5 17:01:27 2021, mugast, S1, Hardware, N/A, Giving up on S1 
We mounted the new S1 detector from Surrey with a new custom cable on several MUFEE cards using the CsI ASICs.
We managed to put voltage on it and get decent leakage current.
We modified the DAS parameters from CsI values to Si values (gain, shaping time, etc).

However as soon as we enable a S1 channel, we get a very large increase of trigger rate (ORD of several 10000) creating huge dead time. Nothing apart pedestal is visible on the energy spectra.
After investigation with Charles and Fred we believe that there is a noise (detector/cable, maybe at high frequency) that goes on the decision chain in the asic (with fast shaper) but that this noise is filtered on the energy coding chain (by the slow shaper) and thus invisible after the ASIC (even with the scope on the analog using the inspection lines).

We give up on S1 and proceed only with 6 working trapezoids and 5 MUST2.
Fixed, e793s, Fri Mar 5 17:03:02 2021, OttoTime, RUN, General, N/A, TimeCalibratorRun 
*** Run Time Calibrator FSC ***
- Run: 623
- MUVI: MUVI1
- Side : MUFEE Y (Ohmic)
- Telescope: 1, 2, 3, 4
Fixed, e793s, Fri Mar 5 17:15:09 2021, OttoTime, RUN, General, N/A, TimeCalibratorRun 
*** Run Time Calibrator FSC ***
- Run: 624
- MUVI: MUVI2
- Side : MUFEE X (Junction)
- Telescope: 1, 2, 3, 4
Fixed, e793s, Fri Mar 5 17:27:25 2021, OttoTime, RUN, General, N/A, TimeCalibratorRun 
*** Run Time Calibrator FSC ***
- Run: 625
- MUVI: MUVI2
- Side : MUFEE Y (Ohmic)
- Telescope: 1, 2, 3, 4
Fixed, e793s, Fri Mar 5 17:39:42 2021, OttoTime, RUN, General, N/A, TimeCalibratorRun 
*** Run Time Calibrator FSC ***
- Run: 626
- MUVI: MUVI3
- Side : MUFEE X (Junction)
- Telescope: 1, 2, 3, 4
Fixed, e793s, Fri Mar 5 17:52:08 2021, OttoTime, RUN, General, N/A, TimeCalibratorRun 
*** Run Time Calibrator FSC ***
- Run: 627
- MUVI: MUVI3
- Side : MUFEE Y (Ohmic)
- Telescope: 1, 2, 3, 4
Fixed, e793s, Fri Mar 5 18:04:33 2021, OttoTime, RUN, General, N/A, TimeCalibratorRun 
*** Run Time Calibrator FSC ***
- Run: 628
- MUVI: MUVI4
- Side : MUFEE X (Junction)
- Telescope: 1,
Fixed, e793s, Fri Mar 5 18:13:03 2021, OttoTime, RUN, General, N/A, TimeCalibratorRun 
*** Run Time Calibrator FSC ***
- Run: 629
- MUVI: MUVI4
- Side : MUFEE Y (Ohmic)
- Telescope: 1,
Fixed, e793s, Sat Mar 6 13:10:07 2021, adrien, ONLINE, General, N/A, FSC screen shot of online at end of run FSC5-6march.png
every detetector have time on either X or Y except for MM5, which is at 90deg and used for elastic, so not a deal breaker.
Fixed, e793s, Sat Mar 6 13:25:38 2021, OttoRun, RUN, General, 3-alpha, Run630 
*************************
Run : 630
*************************

Start at 2021-03-06 13:15:07.038908

run 3 alpha. time calibrator is on but is not giving any trigger so just sending random stop

Stop at 2021-03-08 09:50:00.232468
Stop comment:

Stop at 2021-03-08 15:28:10.213189
Stop comment:

Stop at 2021-03-08 15:28:10.881754
Stop comment:

Stop at 2021-03-08 15:28:11.447832
Stop comment:
Fixed, e793s, Mon Mar 8 08:45:49 2021, Adrien, OFFLINE, General, N/A, TO DO LIST for 8 march 2021 
Here is a todo list for today:

Data conversion:
  • Raw run files are located in /data/mugastX/mugast/acquisition/run/
  • Converting FSC run: 622 to 629 : run_0630.dat.06-03-21_13h15m06s
  • Converting alpha run: 630. warning: there is 3 files for this run :run_0630.dat.06-03-21_13h15m06s and run_0630.dat.06-03-21_13h15m06s.1 and run_0630.dat.06-03-21_13h15m06s.2

Extract histogram for calibration: each macro need to be run twice, once for MUGAST and once for MUST2 if I remember correctly.
  • Extract histograms for FSC run with the macro located : /home/mugast/analysis/nptool/Projects/calibration/Time/ExtractRawHisto_T.C
  • Extract histograms for alpha run with the macro located : /home/mugast/analysis/nptool/Projects/calibration/Energy/ExtractRawHisto_E.C

Analysed the extracted histograms to calibrate: change the appropriate field in the macro before running
  • FSC: /home/mugast/analysis/nptool/Projects/calibration/Time/TimeCalibrator.C
  • alpha: /home/mugast/analysis/nptool/Projects/calibration/Energy/EnergyCalibrator.C

Prepare the calibration file to be used for the online/offline analysis:
  • List all the file you just generated in /home/mugast/analysis/nptool/Projects/MUGAST/Calibration.txt
  • Do some cleanup in the file so it is more readable.
  • Check for missing/noisy strips and adjust config file in /home/mugast/analysis/nptool/Projects/MUGAST/configs

Analysed the calibration run with the new calibration:
  • check T:strip and E:strip
  • Post a summary of the resolution for each detector

Time calibrator on all tac
  • Check the range of each tac
  • wired the start/stop to the TAC inputs
  • do an acquisition with enough statitics
  • analyse it and put the calibration file in Calibration.txt
Fixed, e793s, Mon Mar 8 17:21:14 2021, mugast, GRIT, General, N/A, Run631 - TACs calibration (part 1) 
*************************
Run : 631
*************************

Start at 2021-03-08 17:19:55.467916

TAC calibration.

  • FAG-CATS2 (range 500 ns)
  • Vamos-Agata (range 500 ns)
  • CATS2-CATS2 (not in modular label) (range 500 ns)

Time calibrator
  • 640 ns range
  • 20 ns steps
Fixed, e793s, Mon Mar 8 17:47:29 2021, mugast, GRIT, General, N/A, Run632 - TACs calibration (part 2) 
TAC calibration.

VAMOS-CATS2 (range 2 us)
Mugast-VAMOS (range 2 us )
Mugast-AGATA (range 2 us)

Time calibrator

2.56 us range
40 ns steps