Status ExpNbr Date Author Type Category Target-Source Subject
Fixede744s Thu Apr 11 04:39:48 2019 OttoRunRUNGeneralCH2Run74
*************************
Run : 74
*************************

Start at 2019-04-11 04:37:42.487024

Run Conditions:
  • Operator: AIulian Marlene Diego
  • Trigger: Mugast & Vamos % 1000 & Cats2 % 40000
  • Target/Source: CH2 105 um (Position 2)
  • Beam: 14N
  • Intensity: ~ 2e+5
  • Brho = 0.437 Tm
  • CATS 2 IN

First good data run. 2.7e+5 counts Cats2
Comment:

Stop at 2019-04-11 06:23:39.836186
Stop comment: good run
Fixed  Thu Apr 11 05:03:13 2019 MarlèneRUNHardwareCH2TO DO list
- 2 TACS are not working:
  • T_Si_CATS1 (stop should be CATS n FAG --> to be checked)
  • T_Si_VAMOS (seen now in T_CATS1_CATS2) --> check the signals (if CATS is the START we should use CATS n FAG, if it is the stop it should be delayed by 800 ns , the delay is prepared)
Fixede744s Thu Apr 11 05:08:20 2019 Marlène IulianRUNGeneralCD2Screenshots from RUN 74
RUN 74 with 14N beam and CD2 104um target
First screenshots from MUGAST

Time of flight is OK for MM and MG --> we keep CATS n FAG the way it is
CATS2 position is shifted in X by 3mm but it seems to be well centered on MUST2 and MUGAST

We see proton elastic scattering in MUST2 and in the square (by the way the square is working !)
I had to mask one mate Y on MG4 because it was counting about 50 Hz in the noise.
Attachment 1: correlation_AGATA.png
correlation_AGATA.png
Attachment 2: correlation_TAC.png
correlation_TAC.png
Attachment 3: DeltaE_E_MM.png
DeltaE_E_MM.png
Attachment 4: DeltaE_Tof_MUGAST.png
DeltaE_Tof_MUGAST.png
Attachment 5: MUGAST_impact.png
MUGAST_impact.png
Attachment 6: MUST2_impact.png
MUST2_impact.png
Attachment 7: cats2_pos.png
cats2_pos.png
Attachment 8: TAC.png
TAC.png
Fixede744s Thu Apr 11 06:38:12 2019 DiegoVAMOSHardware TACS modification
+300 ns of delay in the HF validated signal that gives the STOP of T_FPMW_HF && T_CATS2_HF.
Range of TAC FPMW_CATS2 increased to 1us.
Fixede744s Thu Apr 11 06:41:14 2019 OttoRunRUNGeneralCH2Run75
========================================
*************************
Run : 75
*************************

Start at 2019-04-11 06:40:54.479084

Run Conditions:
  • Operator: A. Lemasson
  • Trigger: Mugast & Vamos % 1000 & Cats2 % 40000
  • Target/Source: CH2 105 um (Position 2)
  • Beam: 14N
  • Intensity: ~ 2e+5
  • Brho = 0.437 Tm
  • CATS 2 IN


Comment:

Stop at 2019-04-11 07:29:11.245553
Stop comment:
Fixede744s Thu Apr 11 06:48:23 2019 iulianRUNHardwareCH2TO DO list

mugast wrote:
- 2 TACS are not working:
  • T_Si_CATS1 (stop should be CATS n FAG --> to be checked). Also Ok now. Same problem as below
  • T_Si_VAMOS (seen now in T_CATS1_CATS2) --> check the signals (if CATS is the START we should use CATS n FAG, if it is the stop it should be delayed by 800 ns , the delay is prepared)
    The was a broken Cable from the delay to fan in fan out.

    Still remains T_Vamos_Cats1 with no counts. I suspect the necesity to put a 2 us delay on Cats1, or to inverse it and pout Cats1 fag validated as start

Attachment 1: run275_tacs_mugast.png
run275_tacs_mugast.png
Fixede744s Thu Apr 11 07:00:17 2019 iulianBEAMGeneralCH2ToDo List and plan for today
To Do/Understand
1) T_Vamos_Cats1 in Mugast and T_FPMW_CATS2 in Vamos are not working. I suspect it is the same reason, meaning stop arrives before start. Longer delay or inverse putting Cats2-Fag validated.
2) MM3_E_TOF there is a 5 MeV threshold see below?

For today:
1) We give the beam back to them at 10 am.
2) Analyse the data from RUN 74 & 75 to see the excitation function for 1H(14N,p)
3) If we have the beam back, take more data merged with Agata. Intensity around 2e+5 pps to protect CATS2.
4) If Vamos/Mugast need debugging for reconstruction/validation they have priority.

Summary of the night :
1) Measured the target thicknesses for the targets: 1) Hole 2) CH2 105 um 3) CH2 100 um 4) C 70 um 5) CH2 73 um
2) The C target was not very homogeneous, meaning that was dramatically spreading the momentum distribution of the beam charge states.
3) Vamos debugging went forward, transmission was 95% with Cats2 in with 2e+4 pps beam intensity
4) At 4h30 started the statistic run with Vamos setted at a Brho of 0.437 Tm to completely remove 14N7+ and all others from the focal plane. The beam spot was about 50 mm pied a pied ... This makes imposible the use
Attachment 1: run275_tacs_mugast.png
run275_tacs_mugast.png
FixedTEST Thu Apr 11 07:12:39 2019 OttoH.V.OTHERHardwareN/AHVM_ERROR
*** hvm watcher error ***
cats2 Slot: 13 (A1835 ) Channel:1 Vmon: 600.2 V Imon: 0.52 uA Status: OVER CURRENT

FixedTEST Thu Apr 11 07:15:03 2019 OttoH.V.OTHERHardwareN/AHVM_ERROR
*** hvm watcher error ***
cats2 Slot: 13 (A1835 ) Channel:1 Vmon: 593.7 V Imon: 0.8 uA Status: OVER CURRENT

Fixede744s Thu Apr 11 07:17:33 2019 OttoRunRUNGeneralCH2Run75

OttoRun wrote:
*************************
Run : 75
*************************

Start at 2019-04-11 06:40:54.479084

Run Conditions:
  • Operator: A. Lemasson
  • Trigger: Mugast & Vamos % 1000 & Cats2 % 40000
  • Target/Source: CH2 105 um (Position 2)
  • Beam: 14N
  • Intensity: ~ 2e+5
  • Brho = 0.437 Tm
  • CATS 2 IN


Comment:
Attachment 1: run75_1.png
run75_1.png
Attachment 2: run75_2.png
run75_2.png
Attachment 3: run75_3.png
run75_3.png
Attachment 4: run75_4.png
run75_4.png
Attachment 5: run75_5.png
run75_5.png
Attachment 6: run75_6.png
run75_6.png
Attachment 7: run75_7.png
run75_7.png
Attachment 8: run75_8.png
run75_8.png
Attachment 9: run75_9.png
run75_9.png
Attachment 10: run75_10.png
run75_10.png
Attachment 11: run75_11.png
run75_11.png
Attachment 12: run75_scaler.png
run75_scaler.png
FixedTEST Thu Apr 11 07:17:37 2019 OttoH.V.OTHERHardwareN/AHVM_ERROR
*** hvm watcher error ***
cats2 Slot: 13 (A1835 ) Channel:1 Vmon: 596.1 V Imon: 0.76 uA Status: OVER CURRENT

FixedTEST Thu Apr 11 07:19:00 2019 OttoH.V.OTHERHardwareN/AHVM_ERROR
*** hvm watcher error ***
cats2 Slot: 13 (A1835 ) Channel:1 Vmon: 600.2 V Imon: 0.52 uA Status: OVER CURRENT

FixedTEST Thu Apr 11 07:22:20 2019 OttoH.V.OTHERHardwareN/AHVM_ERROR
*** hvm watcher error ***
cats2 Slot: 13 (A1835 ) Channel:1 Vmon: 598.2 V Imon: 0.86 uA Status: OVER CURRENT

FixedTEST Thu Apr 11 07:24:55 2019 OttoH.V.OTHERHardwareN/AHVM_ERROR
*** hvm watcher error ***
cats2 Slot: 13 (A1835 ) Channel:1 Vmon: 600.2 V Imon: 0.56 uA Status: OVER CURRENT

Fixede744s Thu Apr 11 07:30:15 2019 mugastBEAMSocialN/ABeam stop
The beam will be back around 8:30.
FixedTEST Thu Apr 11 07:51:59 2019 OttoH.V.OTHERHardwareN/AHVM_ERROR
*** hvm watcher error ***
cats2 Slot: 13 (A1835 ) Channel:1 Vmon: 600.2 V Imon: 0.56 uA Status: OVER CURRENT

FixedTEST Thu Apr 11 07:59:36 2019 OttoH.V.OTHERHardwareN/AHVM_ERROR
*** hvm watcher error ***
cats2 Slot: 13 (A1835 ) Channel:1 Vmon: 589.4 V Imon: 0.9 uA Status: OVER CURRENT

Fixede744s Thu Apr 11 08:01:12 2019 OttoRunRUNGeneralCH2Run76
*************************
Run : 76
*************************

Start at 2019-04-11 07:59:50.438662

Run Conditions:
  • Operator: Nikola, Marion
  • Trigger: Mugast & Vamos % 1000 & Cats2 % 40000
  • Target/Source: CH2 105 um (Position 2)
  • Beam: 14N
  • Intensity: ~ 2e+5
  • Brho = 0.437 Tm
  • CATS 2 IN


Comment: Beam stopped (Balise).

Stop at 2019-04-11 08:33:56.045621
Stop comment:
FixedTEST Thu Apr 11 08:03:05 2019 OttoH.V.OTHERHardwareN/AHVM_ERROR
*** hvm watcher error ***
cats2 Slot: 13 (A1835 ) Channel:1 Vmon: 598.8 V Imon: 0.58 uA Status: OVER CURRENT

FixedTEST Thu Apr 11 08:05:37 2019 OttoH.V.OTHERHardwareN/AHVM_ERROR
*** hvm watcher error ***
cats2 Slot: 13 (A1835 ) Channel:1 Vmon: 592.2 V Imon: 0.68 uA Status: OVER CURRENT