MUST2 SAMURAI_2018 S3-LEB-LPC SUPERNEMO MUGAST EXPAND SCALP GALATRON HiCARI VELO
  MUGAST  Not logged in MUGAST
Entry  Thu Apr 11 05:03:13 2019, Marlène, , RUN, Hardware, Fixed, CH2, TO DO list 
    Reply  Thu Apr 11 06:48:23 2019, iulian, e744s, RUN, Hardware, Fixed, CH2, TO DO list run275_tacs_mugast.png
Message ID: 3978     Entry time: Thu Apr 11 06:48:23 2019     In reply to: 3973
Author: iulian 
ExpNbr: e744s 
Type: RUN 
Category: Hardware 
Status: Fixed 
Target-Source: CH2 
Subject: TO DO list 

mugast wrote:
- 2 TACS are not working:
  • T_Si_CATS1 (stop should be CATS n FAG --> to be checked). Also Ok now. Same problem as below
  • T_Si_VAMOS (seen now in T_CATS1_CATS2) --> check the signals (if CATS is the START we should use CATS n FAG, if it is the stop it should be delayed by 800 ns , the delay is prepared)
    The was a broken Cable from the delay to fan in fan out.

    Still remains T_Vamos_Cats1 with no counts. I suspect the necesity to put a 2 us delay on Cats1, or to inverse it and pout Cats1 fag validated as start

Attachment 1: run275_tacs_mugast.png  39 kB  Uploaded Thu Apr 11 07:54:58 2019  | Hide | Hide all