Status |
ExpNbr |
Date |
Author |
Type |
Category |
Target-Source |
Subject |
Fixed | e744s |
Fri Apr 5 22:13:33 2019 |
OttoRun | RUN | General | Ti-t | Run254 |
*************************
Run : 254
*************************
Start at 2019-04-05 22:13:28.719268
Run Conditions:
- Operator:
- Trigger:
- Target/Source:
- Beam:
- Intensity:
Comment:
Stop at 2019-04-05 22:38:50.168158
Stop comment: stop to put Vamos in the trigger |
Fixed | e744s |
Fri Apr 5 22:39:39 2019 |
OttoRun | RUN | General | Ti-t | Run255 |
*************************
Run : 255
*************************
Start at 2019-04-05 22:39:35.688874
Run Conditions:
- Operator:
- Trigger:
- Target/Source:
- Beam:
- Intensity:
Comment:
Stop at 2019-04-05 22:41:54.607652
Stop comment: |
Fixed | TEST |
Fri Dec 14 09:08:46 2018 |
Adrien Matta | OTHER | Social | N/A | Test Post |
MUGAST ELOG is now ONLINE |
Fixed | TEST |
Wed Jan 16 17:36:30 2019 |
Valérian-Marlène | GRIT | General | N/A | Calimero tests - How to configure Calimero in GECO |
Tests of Calimero time calibration with MUVI1 channel 2 (MM2)
1- channel 3 of all mates selected (see screeshots)
2- channel 1 of all mates
3- channel 1 of all mates - with channels enabled !!!!!
4- channel 1 of all mates - with channels enabled !!!!!
5- all channels telescope MM2
Number of counts = total number of counts for one channel on all mates
Conclusion :
Options to be chosen
1- with channels enabled
2- 10000 for the statistics
Remarks
To run calimero on MUVI1, caliWatcher should be set to 10202 and CaliSlave to 10223
The opposite for MUVI2, caliWatcher 10223, CaliSlave 10202 |
Fixed | TEST |
Fri Jan 18 15:32:50 2019 |
Adrien Valérian | GRIT | General | N/A | Calimero tests Muvi2 MM7 MG10C |
After disabling nptool Multithreading, online is working fine again.
Concerning Calimero, it is currently working both on MUVI1 and MUVI2 for the X at least.
Joined here is the result of Calimero for MG10C on MUVI2 channel 3 (MM7). |
Fixed | |
Tue Jan 22 11:15:15 2019 |
Marlène | GRIT | General | N/A | Square detectors |
MG9C (thin square detector coupled with thick square detector unplugged) noisy
On X channels --> no noise problem ( about 100 ORD in the dark)
On Y channels --> MATE 10 & 11 noisy ! (see picture below with noisy Y piedestals)
With internal pulser (trigered by CK_TST) the counting rate is OK only if the thresholds are set at 1 MeV. If they are set at 500 keV, the counting rate is 10 times higher than the CK_TST
For MG10C, ORD is OK ! |
Fixed | |
Fri Feb 15 15:31:28 2019 |
Marlène | GRIT | General | N/A | Detectors bias |
|
Fixed | com2019 |
Mon Feb 18 10:41:36 2019 |
Marlene | GRIT | General | N/A | Bias & current of detectors |
|
Fixed | TEST |
Thu Feb 21 16:43:45 2019 |
Valérian, Freddy, Iulian and Marlène | GRIT | Hardware | N/A | Current measurements |
Joined are the the I(V).
Detectors seems to respond accordingly with the previous measurements from Marlène.
Annular detector curve is quite strange…
Joined files :
Depletion_Mugast_MG.pdf -> summary for trapezoidal + annular detectors
Depletion_Mugast_M2.pdf -> summary for Must2 detectors
Depletion_Mugast.xlsx -> Excel file |
Pinned | TEST |
Tue Feb 26 09:30:21 2019 |
Freddy | OTHER | Hardware | N/A | Cabling - MUVI / HT-BT / SA-SL |
Cabling scheme - to update until final |
Fixed | TEST |
Tue Feb 26 13:21:32 2019 |
iulian freddy | GRIT | Software | N/A | run 42 Calimero run MUVI 1 on X sectors |
run #42
Calimero MUVI1 X
run #41
Calimero MUVI secttor 1X |
Fixed | TEST |
Tue Feb 26 13:50:36 2019 |
iulian freddy | GRIT | Software | N/A | run 43 Calimero run MUVI 1 on Y sectors |
run #43
Calimero MUVI1 Y |
Fixed | TEST |
Tue Feb 26 14:52:49 2019 |
iulian freddy | GRIT | Software | N/A | run 44 Calimero run MUVI 2 on X sectors (bad run) |
run #44 bad run
Calimero MUVI2 X
During the run we noticed that time calibrator is on MUVI1 only . |
Fixed | TEST |
Mon Mar 4 14:34:31 2019 |
Valerian, Marlène, Iulian | MUST2 | General | N/A | MUST2 positions (based on e755) |
Based on experiment e755, the MUST2 config is the following :
T1, PCB10:
X128Y1.......X1
. .
. .
Y128.......
T2, PCB5:
Y128.......X128Y1
. .
. .
.......X1
T3, PCB4:
.......Y128
. .
. .
X1.......X128Y1
T4, PCB7:
X1.......
. .
. .
X128Y1.......Y128 |
Fixed | TEST |
Tue Mar 5 10:16:03 2019 |
iulian | MUST2 | Software | N/A | run 57 Gamme 300 ns Time Calibration run (Calimero) on MUVI 3 (MUST) X sectors more stats (10000) |
RUNS 53,54,55,56 are bad runs
Run 57
Calimero on Muvi3 MM1(X)
Gamme 300 ns
Procedure:
0) HT on the detectors Off
1) Apply Das config
2) Put Das offline
3) Start Geco
4) Activate on each of the sector to calibrate the X side (see bellow image)
5) execute Calimero.exe in calimero directory
6) modify the calimero config on Geco (see bellow near config button)
7) Start the run in RCC
8) Start calimero (start button in Geco) |
Fixed | TEST |
Tue Mar 5 12:13:41 2019 |
iulian Marlene | MUST2 | Software | N/A | run 60 Gamme 600 ns Time Calibration run (Calimero) on MUVI 3 MM1 X |
RUNS 58,59,60 are bad runs
Run 61
Calimero on Muvi3 MM1(X)
Gamme 600 ns
Procedure:
0) HT on the detectors Off
1) Apply Das config
2) Put Das offline
3) Start Geco
4) Activate on each of the sector to calibrate the X side (see bellow image)
5) execute Calimero.exe in calimero directory
6) modify the calimero config on Geco (see bellow near config button)
7) Start the run in RCC
8) Start calimero (start button in Geco) |
Fixed | TEST |
Tue Mar 5 15:53:04 2019 |
iulian Marlene | MUST2 | Software | N/A | Calimero problems |
problems with Calimero solved by killing some processes on lpcgrit related with Narval.
to find the processes on lpcgrit:
ps aux | grep Cali*
ps aux | grep Narval
kill -9 all the ids
Other possible solution:
start_acq on lpcgrit
tk followed by kall
exit |
Fixed | TEST |
Tue Mar 5 16:20:11 2019 |
iulian Marlene | MUST2 | Software | N/A | run 77 Gamme 600 ns Time Calibration run (Calimero) on MUVI 3 MM1 X . good run |
Run 76
Calimero on Muvi3 MM1(X)
Gamme 600 ns
Procedure:
0) HT on the detectors Off
1) Apply Das config
2) Put Das offline
3) Start Geco
4) Activate on each of the sector to calibrate the X side (see bellow image)
5) execute Calimero.exe in calimero directory
6) modify the calimero config on Geco (see bellow near config button)
7) Start the run in RCC
8) Start calimero (start button in Geco) |
Fixed | TEST |
Tue Mar 5 16:42:56 2019 |
iulian Marlene | MUST2 | Software | N/A | run 79 Gamme 600 ns Time Calibration run (Calimero) on MUVI 3 MM2 X . good run |
Run 79
Run 78 bad
Calimero on Muvi3 MM2(X)
Gamme 600 ns
Procedure:
0) HT on the detectors Off
1) Apply Das config
2) Put Das offline
3) Start Geco
4) Activate on each of the sector to calibrate the X side (see bellow image)
5) execute Calimero.exe in calimero directory
6) modify the calimero config on Geco (see bellow near config button)
7) Start the run in RCC
8) Start calimero (start button in Geco) |
Fixed | TEST |
Tue Mar 5 17:11:29 2019 |
iulian Marlene | MUST2 | Software | N/A | run 81 Gamme 600 ns Time Calibration run (Calimero) on MUVI 3 MM3 X . good run |
Run 81
Run 80 bad
Calimero on Muvi3 MM3(X)
Gamme 600 ns
Procedure:
0) HT on the detectors Off
1) Apply Das config
2) Put Das offline
3) Start Geco
4) Activate on each of the sector to calibrate the X side (see bellow image)
5) execute Calimero.exe in calimero directory
6) modify the calimero config on Geco (see bellow near config button)
7) Start the run in RCC
8) Start calimero (start button in Geco) |