Status |
ExpNbr |
Date |
Author |
Type |
Category |
Target-Source |
Subject |
Text |
 |
Fixed | e793s |
Wed Mar 17 14:59:17 2021 |
OttoTime | RUN | General | N/A | TimeCalibratorRun | *** Run Time Calibrator FSC ***
- Run: 649
- MUVI: MUVI3
|
|
Fixed | e793s |
Wed Mar 17 15:11:37 2021 |
OttoTime | RUN | General | N/A | TimeCalibratorRun | *** Run Time Calibrator FSC ***
- Run: 650
- MUVI: MUVI4
|
|
Ongoing | e793s |
Wed Mar 17 15:17:39 2021 |
Emmanuel C | OFFLINE | General | | New gamma gamma analysis | The level scheme is based on coherent check
of
1- gamma gamma
|
|
Fixed | e793s |
Wed Mar 17 15:20:08 2021 |
OttoTime | RUN | General | N/A | TimeCalibratorRun | *** Run Time Calibrator FSC ***
- Run: 651
- MUVI: MUVI4
|
|
Fixed | e793s |
Wed Mar 17 19:19:05 2021 |
Franco | OFFLINE | General | CD2 | Mugast detectors disaligned in Ex | The Ex distributions gated on the different
MG detectors show large differences, up to
500 keV. In the attached figure I show as |
 |
Fixed | e793s |
Thu Mar 18 16:25:56 2021 |
Emmanuel C | OFFLINE | General | | Efficiency gamma AGATA --- real measurement run70 | [quote="Emmanuel C"] TF1 *fit_1 = new TF1("fit_1","TMath::Exp([0]+[1]*TMath::Log(x)+[2]*pow(TMath::Log(x),2.0)+[3]*pow(TMath::Log(x),3.0)+[4]*pow(TMath::Log(x),4.0))",10,5000);
//NRJ traite en keV et efficiency en %
|
|
Fixed | e793s |
Fri Mar 19 09:54:58 2021 |
Adrien, Freddy and Franco | GRIT | General | 3-alpha | Alpha calibration and noise on MG3 and MG4 after the experiment | While starting the alpha source runs after
the experiment we found unexpected noise
on MG3 and MG4 which cannot be excluded just |
|
Fixed | e793s |
Mon Mar 22 16:35:46 2021 |
OttoRun | RUN | General | N/A | Run67 | *************************
[SIZE=3][B]Run : 67[/B][/SIZE]
*************************
|
|
Fixed | e793s |
Mon Mar 22 18:15:50 2021 |
mugast | RUN | General | N/A | TACS calibration - run 662 | TACS:
FAG-CATS2 (range 500 ns)
|
|
Fixed | e793s |
Mon Mar 22 19:04:55 2021 |
mugast | RUN | General | N/A | TACS calibration - run 653 | TACS:
MUGAST-AGATA (range 2 us)
|
|
Fixed | e793s |
Tue Mar 23 10:22:48 2021 |
Emmanuel C | OFFLINE | General | | Efficiency gamma AGATA --- real measurement run70 |
I have been working on the high energy response.
The point is that we do not have source measurement |
|
Pinned | e786s |
Wed Apr 10 13:30:48 2019 |
Valerian, Adrien and Antoine (edit by Louis) | OFFLINE | Software | N/A | How to perform analysis for e786s | [U][B]
Here is the updated procedure to convert
a run, with VAMOS data and add those data |
|
Fixed | e786s |
Fri May 31 09:53:14 2019 |
Marlène | GRIT | General | | Alpha source --> status of detectors | MG3T has been fixed by changing the X kapton.
I have removed aluminium foil on square detectors, |
|
Fixed | e786s |
Mon Jun 3 18:00:10 2019 |
Marlène | GRIT | General | | MUGAST detectors status --> MG4T | The problem of MG4T ha sbeen solved by changing
the feedthrough.
The pulser on Y was not working and we were |
|
Fixed | e786s |
Wed Jun 12 17:59:01 2019 |
mugast | OTHER | Software | | Online Energy Calibration | Updated Online Energy calibration for MUGAST,
based on run_0231 data |
 |
Fixed | e786s |
Wed Jun 12 18:11:04 2019 |
mugast | OTHER | Software | | Online Energy Calibration | |
|
Fixed | e786s |
Wed Jun 19 10:09:10 2019 |
mugast | MUST2 | Hardware | N/A | Time calibrator cabled | range 640 ns
period 20 ns |
|
Fixed | e786s |
Wed Jun 19 12:02:07 2019 |
OttoTime | RUN | General | N/A | TimeCalibratorRun | *** Run Time Calibrator FSC ***
- Run: 237
- MUVI: MUVI1
|
|
Fixed | e786s |
Wed Jun 19 12:24:43 2019 |
OttoTime | RUN | General | N/A | TimeCalibratorRun | *** Run Time Calibrator FSC ***
- Run: 238
- MUVI: MUVI1
|
|
Fixed | e786s |
Wed Jun 19 12:48:13 2019 |
OttoTime | RUN | General | N/A | TimeCalibratorRun | *** Run Time Calibrator FSC ***
- Run: 239 - MUVI: MUVI2
- Side : MUFEE X (Junction)
|
|