Fixed, e793s, Wed Mar 17 14:59:17 2021, OttoTime, RUN, General, N/A, TimeCalibratorRun
|
*** Run Time Calibrator FSC ***
- Run: 649
- MUVI: MUVI3
|
Fixed, e793s, Wed Mar 17 15:11:37 2021, OttoTime, RUN, General, N/A, TimeCalibratorRun
|
*** Run Time Calibrator FSC ***
- Run: 650
- MUVI: MUVI4
|
Ongoing, e793s, Wed Mar 17 15:17:39 2021, Emmanuel C, OFFLINE, General, , New gamma gamma analysis
|
The level scheme is based on coherent check of
1- gamma gamma
2- gamma gated by Ex
|
Fixed, e793s, Wed Mar 17 15:20:08 2021, OttoTime, RUN, General, N/A, TimeCalibratorRun
|
*** Run Time Calibrator FSC ***
- Run: 651
- MUVI: MUVI4
|
Fixed, e793s, Wed Mar 17 19:19:05 2021, Franco, OFFLINE, General, CD2, Mugast detectors disaligned in Ex 
|
The Ex distributions gated on the different MG detectors show large differences, up to 500 keV. In the attached figure I show as an example the comparison
between two nearby detectors, MG3 and MG4.
I tried a rough alignment of the Ex by shifting it manually and setting the first main peak at Ex=0 (essentially taking MG5 as the reference, since his |
Fixed, e793s, Thu Mar 18 16:25:56 2021, Emmanuel C, OFFLINE, General, , Efficiency gamma AGATA --- real measurement run70
|
[quote="Emmanuel C"] TF1 *fit_1 = new TF1("fit_1","TMath::Exp([0]+[1]*TMath::Log(x)+[2]*pow(TMath::Log(x),2.0)+[3]*pow(TMath::Log(x),3.0)+[4]*pow(TMath::Log(x),4.0))",10,5000);
//NRJ traite en keV et efficiency en %
|
Fixed, e793s, Fri Mar 19 09:54:58 2021, Adrien, Freddy and Franco, GRIT, General, 3-alpha, Alpha calibration and noise on MG3 and MG4 after the experiment
|
While starting the alpha source runs after the experiment we found unexpected noise on MG3 and MG4 which cannot be excluded just by masking some Y mates
(The X mates were already masked for both of them). We cannot figure out the origin of this noise.
|
Fixed, e793s, Mon Mar 22 16:35:46 2021, OttoRun, RUN, General, N/A, Run67
|
*************************
[SIZE=3][B]Run : 67[/B][/SIZE]
*************************
|
Fixed, e793s, Mon Mar 22 18:15:50 2021, mugast, RUN, General, N/A, TACS calibration - run 662
|
TACS:
FAG-CATS2 (range 500 ns)
|
Fixed, e793s, Mon Mar 22 19:04:55 2021, mugast, RUN, General, N/A, TACS calibration - run 653
|
TACS:
MUGAST-AGATA (range 2 us)
|
Fixed, e793s, Tue Mar 23 10:22:48 2021, Emmanuel C, OFFLINE, General, , Efficiency gamma AGATA --- real measurement run70
|
I have been working on the high energy response.
The point is that we do not have source measurement beyond 2 MeV to constrain the fit.
|
Pinned, e786s, Wed Apr 10 13:30:48 2019, Valerian, Adrien and Antoine (edit by Louis), OFFLINE, Software, N/A, How to perform analysis for e786s
|
[U][B]
Here is the updated procedure to convert a run, with VAMOS data and add those data to the Kinematic plot.
[/B][/U]
|
Fixed, e786s, Fri May 31 09:53:14 2019, Marlène, GRIT, General, , Alpha source --> status of detectors
|
MG3T has been fixed by changing the X kapton.
I have removed aluminium foil on square detectors, the noise is slightly higher.
|
Fixed, e786s, Mon Jun 3 18:00:10 2019, Marlène, GRIT, General, , MUGAST detectors status --> MG4T
|
The problem of MG4T ha sbeen solved by changing the feedthrough.
The pulser on Y was not working and we were seeing no events (no ORD) because there was a problem with the bias of board. The issue is due to the feedthrough.
So now MG4T (HT &BT) are plugged in a free feedthrough (below MG1T) and I see pulser signals on Y.
|
Fixed, e786s, Wed Jun 12 17:59:01 2019, mugast, OTHER, Software, , Online Energy Calibration 
|
Updated Online Energy calibration for MUGAST, based on run_0231 data |
Fixed, e786s, Wed Jun 12 18:11:04 2019, mugast, OTHER, Software, , Online Energy Calibration
|
|
Fixed, e786s, Wed Jun 19 10:09:10 2019, mugast, MUST2, Hardware, N/A, Time calibrator cabled
|
range 640 ns
period 20 ns |
Fixed, e786s, Wed Jun 19 12:02:07 2019, OttoTime, RUN, General, N/A, TimeCalibratorRun
|
*** Run Time Calibrator FSC ***
- Run: 237
- MUVI: MUVI1
|
Fixed, e786s, Wed Jun 19 12:24:43 2019, OttoTime, RUN, General, N/A, TimeCalibratorRun
|
*** Run Time Calibrator FSC ***
- Run: 238
- MUVI: MUVI1
|
Fixed, e786s, Wed Jun 19 12:48:13 2019, OttoTime, RUN, General, N/A, TimeCalibratorRun
|
*** Run Time Calibrator FSC ***
- Run: 239 - MUVI: MUVI2
- Side : MUFEE X (Junction)
|
|