Fixed, e793s, Wed Mar 17 14:59:17 2021, OttoTime, RUN, General, N/A, TimeCalibratorRun 
*** Run Time Calibrator FSC ***
  - Run: 649
  - MUVI: MUVI3
Fixed, e793s, Wed Mar 17 15:11:37 2021, OttoTime, RUN, General, N/A, TimeCalibratorRun 
*** Run Time Calibrator FSC ***
  - Run: 650
  - MUVI: MUVI4
Ongoing, e793s, Wed Mar 17 15:17:39 2021, Emmanuel C, OFFLINE, General, , New gamma gamma analysis 48K.pdf
The level scheme is based on coherent check of
1- gamma gamma
2- gamma gated by Ex
Fixed, e793s, Wed Mar 17 15:20:08 2021, OttoTime, RUN, General, N/A, TimeCalibratorRun 
*** Run Time Calibrator FSC ***
  - Run: 651
  - MUVI: MUVI4
Fixed, e793s, Wed Mar 17 19:19:05 2021, Franco, OFFLINE, General, CD2, Mugast detectors disaligned in Ex detectors_disalignment_Ex.pngEx_aligned_vs_unaligned.png
The Ex distributions gated on the different MG detectors show large differences, up to 500 keV. In the attached figure I show as an example the comparison
between two nearby detectors, MG3 and MG4.
I tried a rough alignment of the Ex by shifting it manually and setting the first main peak at Ex=0 (essentially taking MG5 as the reference, since his
    Fixed, e793s, Thu Mar 18 16:25:56 2021, Emmanuel C, OFFLINE, General, , Efficiency gamma AGATA --- real measurement run70 
[quote="Emmanuel C"] TF1 *fit_1 = new TF1("fit_1","TMath::Exp([0]+[1]*TMath::Log(x)+[2]*pow(TMath::Log(x),2.0)+[3]*pow(TMath::Log(x),3.0)+[4]*pow(TMath::Log(x),4.0))",10,5000);
 //NRJ traite en keV et efficiency en %
Fixed, e793s, Fri Mar 19 09:54:58 2021, Adrien, Freddy and Franco, GRIT, General, 3-alpha, Alpha calibration and noise on MG3 and MG4 after the experiment 
While starting the alpha source runs after the experiment we found unexpected noise on MG3 and MG4 which cannot be excluded just by masking some Y mates
(The X mates were already masked for both of them). We cannot figure out the origin of this noise.
Fixed, e793s, Mon Mar 22 16:35:46 2021, OttoRun, RUN, General, N/A, Run67 
*************************
  [SIZE=3][B]Run  : 67[/B][/SIZE]
*************************
Fixed, e793s, Mon Mar 22 18:15:50 2021, mugast, RUN, General, N/A, TACS calibration - run 662 
TACS:

    FAG-CATS2 (range 500 ns)
Fixed, e793s, Mon Mar 22 19:04:55 2021, mugast, RUN, General, N/A, TACS calibration - run 653 
TACS:

MUGAST-AGATA (range 2 us)
    Fixed, e793s, Tue Mar 23 10:22:48 2021, Emmanuel C, OFFLINE, General, , Efficiency gamma AGATA --- real measurement run70 effi.png

I have been working on the high energy response.
The point is that we do not have source measurement beyond 2 MeV to constrain the fit. 
Pinned, e786s, Wed Apr 10 13:30:48 2019, Valerian, Adrien and Antoine (edit by Louis), OFFLINE, Software, N/A, How to perform analysis for e786s 
[U][B]
Here is the updated procedure to convert a run, with VAMOS data and add those data to the Kinematic plot.
[/B][/U]
Fixed, e786s, Fri May 31 09:53:14 2019, Marlène, GRIT, General, , Alpha source --> status of detectors 
MG3T has been fixed by changing the X kapton.

I have removed aluminium foil on square detectors, the noise is slightly higher.
Fixed, e786s, Mon Jun 3 18:00:10 2019, Marlène, GRIT, General, , MUGAST detectors status --> MG4T  
The problem of MG4T ha sbeen solved by changing the feedthrough.
The pulser on Y was not working and we were seeing no events (no ORD) because there was a problem with the bias of board. The issue is due to the feedthrough.
So now MG4T (HT &BT) are plugged in a free feedthrough (below MG1T) and I see pulser signals on Y. 
Fixed, e786s, Wed Jun 12 17:59:01 2019, mugast, OTHER, Software, , Online Energy Calibration x_E_cal.pngy_E_cal2.png
Updated Online Energy calibration for MUGAST, based on run_0231 data
    Fixed, e786s, Wed Jun 12 18:11:04 2019, mugast, OTHER, Software, , Online Energy Calibration 
 
Fixed, e786s, Wed Jun 19 10:09:10 2019, mugast, MUST2, Hardware, N/A, Time calibrator cabled 
range 640 ns
period 20 ns
Fixed, e786s, Wed Jun 19 12:02:07 2019, OttoTime, RUN, General, N/A, TimeCalibratorRun 
*** Run Time Calibrator FSC ***
  - Run: 237
  - MUVI: MUVI1
Fixed, e786s, Wed Jun 19 12:24:43 2019, OttoTime, RUN, General, N/A, TimeCalibratorRun 
*** Run Time Calibrator FSC ***
  - Run: 238
  - MUVI: MUVI1
Fixed, e786s, Wed Jun 19 12:48:13 2019, OttoTime, RUN, General, N/A, TimeCalibratorRun 
*** Run Time Calibrator FSC ***
  - Run: 239  - MUVI: MUVI2