MUST2 SAMURAI_2018 S3-LEB-LPC SUPERNEMO MUGAST EXPAND SCALP GALATRON HiCARI VELO
  MUGAST, Page 130 of 132  Not logged in MUGAST
New entries since:Thu Jan 1 01:00:00 1970
Status ExpNbr Datedown Author Type Category Target-Source Subject
FixedTEST Fri Mar 22 18:15:39 2019 OttoRUNGeneralN/ATimeCalibratorRun
*** Run Time Calibrator FSC ***
- Run: 122
- MUVI: MUVI3
- Side : MUFEE Y (Ohmic)
- Telescope: 1, 2, 3, 4
FixedTEST Fri Mar 22 18:06:11 2019 OttoRUNGeneralN/ATimeCalibratorRun
*** Run Time Calibrator FSC ***
- Run: 121
- MUVI: MUVI3
- Side : MUFEE X (Junction)
- Telescope: 1, 2, 3, 4
FixedTEST Fri Mar 22 17:56:37 2019 OttoRUNGeneralN/ATimeCalibratorRun
*** Run Time Calibrator FSC ***
- Run: 120
- MUVI: MUVI2
- Side : MUFEE Y (Ohmic)
- Telescope: 1, 2, 3, 4
FixedTEST Fri Mar 22 17:47:04 2019 OttoRUNGeneralN/ATimeCalibratorRun
*** Run Time Calibrator FSC ***
- Run: 119
- MUVI: MUVI2
- Side : MUFEE X (Junction)
- Telescope: 1, 2, 3, 4
FixedTEST Fri Mar 22 17:37:37 2019 OttoRUNGeneralN/ATimeCalibratorRun
*** Run Time Calibrator FSC ***
- Run: 118
- MUVI: MUVI1
- Side : MUFEE Y (Ohmic)
- Telescope: 1, 2, 3, 4
FixedTEST Fri Mar 22 17:28:09 2019 OttoRUNGeneralN/ATimeCalibratorRun
*** Run Time Calibrator FSC ***
- Run: 117
- MUVI: MUVI1
- Side : MUFEE X (Junction)
- Telescope: 1, 2, 3, 4
FixedTEST Thu Mar 21 13:28:06 2019 Valerian and AdrienDAQSoftwareN/AFirst fully functionnal time calibration run on X and Y of MG1
Our program is able to perform the time calibration of our detector for both X and Y, see picture attached.
Attachment 1: CALIMEROY1.png
CALIMEROY1.png
Attachment 2: FIRST_TIMECALIBRATION_WITHOUT_CALIMERO.png
FIRST_TIMECALIBRATION_WITHOUT_CALIMERO.png
FixedTEST Thu Mar 21 10:37:47 2019 Adrien and ValerianMUST2GeneralN/ATest TOF must2
To make sure the mate work correctly we took an alpha run with a delayed fag on the MUVI stop:
- all mate register a time in the the middle of the range as expected (fag delayed by 350ns, range is 600ns)

Test with time calibrator, all channel are enable, pulser on channel 3 of each mate T1X:
- energy spectrum: pulser where we expect it.
- we expect to see a time calibrator spectrum on channel 3 of each mate. instead we see times spectrum on Channel 3 of mate 1 and 2, channel 12 of mate 1, channel 14 of mate2. nothing else

Conclusion

The problem was that the synctst had to be checked and ord unchecked
Attachment 1: Time_behavior_withDAS.png
Time_behavior_withDAS.png
Fixed  Tue Mar 19 19:35:53 2019 marleneGRITGeneral RUN 98 3alpha source all detectors
RUN 98
3 alpha source
all detectors (trap,square, MUST2,annular)
Temp=15deg
Acquisition mugast
FixedTEST Mon Mar 18 18:31:18 2019 valerian marlèneGRITGeneral3-alphaRUN 20 (com2019) 3 alpha overnight
RUN20

Run with double 3alpha source MUST2+MG1_7+MG11
temperature -4 deg on both cooling

Acquisition with VAMOS+MUGAST coupled (com2019)

Time range =600ns
pedestal aligned and suppressed

run start at 18h23 monday 18

run stop at 8h34 tuesday 19

about 12Go of data
Attachment 1: RUN20_HV_MG_3lapha.png
RUN20_HV_MG_3lapha.png
Attachment 2: RUN20_3alpha_HV_MUST2.png
RUN20_3alpha_HV_MUST2.png
Fixed  Tue Mar 12 10:21:17 2019 MarlèneMUST2General Debug Calimero Y
Debug of Calimero

test of channels (mate) masking : OK with DAS, OK with GECCO (see attachment) when done in the "disable channels" of GECCO

With calimero, when we are on Y, when we click right to mask a mate we see 'disable mate 2' instead of 'disable mate 10' !!!
Attachment 1: test_GECO_masquage_mate2&10activees_seulement.png
test_GECO_masquage_mate2&10activees_seulement.png
FixedTEST Thu Mar 7 14:02:03 2019 Marlène IulianMUST2GeneralN/Atest of MUST2 electronics
Test with pulser at 20 kHz
The OR of MUVI was scaled down by a factor of 100, to provoke some resets
FixedTEST Thu Mar 7 09:29:47 2019 MarleneGRITGeneral run 96 double alpha source run shifted 60mm
RUN 96

double alpha source
MG1
MG3
MG4
MG5

MG7
-
-
MG11

MM1
MM2
MM3
MM4

Missing strips in Y the same as in run 40

Problem with the annular MG11 -> no current when bias is put... --> to be checked

Problem with the insertion of the target holder --> solved

I also checked again MG9 (still noisy)
and MG10 with 140V I=0,52uA and counting rate is the same order of magnitude as trapezoid. Spectra are OK (not saved).
Attachment 1: run96_MG7_MG11notworking.png
run96_MG7_MG11notworking.png
Attachment 2: run96_3alphasource_shifted_MG1-5.png
run96_3alphasource_shifted_MG1-5.png
Attachment 3: run96_HV2.png
run96_HV2.png
Attachment 4: run96_HV1.png
run96_HV1.png
FixedTEST Wed Mar 6 15:02:51 2019 ValerianMUST2Hardware3-alphaCooling temperature is relevant for the resolution
Using run 52 -> 13deg and run 87 -> -5deg.

We see that the resolution improves at -5 degree. See attached picture as an example for MM2 X.
Attachment 1: MM2X_13deg.png
MM2X_13deg.png
Attachment 2: MM2X_minus5deg.png
MM2X_minus5deg.png
FixedTEST Tue Mar 5 18:18:46 2019 iulian MarleneMUST2Hardware3-alpharun 97 3a run Muvi3 night run
Run 87

stop@ 5:42 am

3a run Muvi3 (MM)
-4 deg
pedestals aligned and suppressed
Attachment 1: run87_3alpha_4mm_spectra.png
run87_3alpha_4mm_spectra.png
FixedTEST Tue Mar 5 18:03:24 2019 iulian MarleneMUST2SoftwareN/ACalimero problem on Y side
Calimero not working properly on Y side of any mm detector
Attachment 1: run83_calimero_mm4Y_spectra.png
run83_calimero_mm4Y_spectra.png
Attachment 2: run834calimero_mm2Y_spectra.png
run834calimero_mm2Y_spectra.png
FixedTEST Tue Mar 5 17:48:38 2019 iulian MarleneMUST2SoftwareN/Arun 82 Gamme 600 ns Time Calibration run (Calimero) on MUVI 3 MM4 X . good run
Run 82

Calimero on Muvi3 MM4(X)

Gamme 600 ns
Attachment 1: run82_calimero_mm4X_spectra.png
run82_calimero_mm4X_spectra.png
FixedTEST Tue Mar 5 17:11:29 2019 iulian MarleneMUST2SoftwareN/Arun 81 Gamme 600 ns Time Calibration run (Calimero) on MUVI 3 MM3 X . good run
Run 81

Run 80 bad
Calimero on Muvi3 MM3(X)

Gamme 600 ns

Procedure:

0) HT on the detectors Off
1) Apply Das config
2) Put Das offline
3) Start Geco
4) Activate on each of the sector to calibrate the X side (see bellow image)
5) execute Calimero.exe in calimero directory
6) modify the calimero config on Geco (see bellow near config button)
7) Start the run in RCC
8) Start calimero (start button in Geco)
Attachment 1: run81_calimero_mm3X_spectra.png
run81_calimero_mm3X_spectra.png
FixedTEST Tue Mar 5 16:42:56 2019 iulian MarleneMUST2SoftwareN/Arun 79 Gamme 600 ns Time Calibration run (Calimero) on MUVI 3 MM2 X . good run
Run 79

Run 78 bad
Calimero on Muvi3 MM2(X)

Gamme 600 ns

Procedure:

0) HT on the detectors Off
1) Apply Das config
2) Put Das offline
3) Start Geco
4) Activate on each of the sector to calibrate the X side (see bellow image)
5) execute Calimero.exe in calimero directory
6) modify the calimero config on Geco (see bellow near config button)
7) Start the run in RCC
8) Start calimero (start button in Geco)
Attachment 1: run79_calimero_mm2X_spectra.png
run79_calimero_mm2X_spectra.png
FixedTEST Tue Mar 5 16:20:11 2019 iulian MarleneMUST2SoftwareN/Arun 77 Gamme 600 ns Time Calibration run (Calimero) on MUVI 3 MM1 X . good run
Run 76


Calimero on Muvi3 MM1(X)

Gamme 600 ns

Procedure:

0) HT on the detectors Off
1) Apply Das config
2) Put Das offline
3) Start Geco
4) Activate on each of the sector to calibrate the X side (see bellow image)
5) execute Calimero.exe in calimero directory
6) modify the calimero config on Geco (see bellow near config button)
7) Start the run in RCC
8) Start calimero (start button in Geco)
Attachment 1: run77_calimero_mm1X_spectra.png
run77_calimero_mm1X_spectra.png

ELOG Home Page