Status |
ExpNbr |
Date |
Author |
Type |
Category |
Target-Source |
Subject |
Fixed | e768s |
Wed Jul 17 13:55:54 2019 |
Kseniia et al | MUST2 | Hardware | | The silicons are polarised again |
The LV and HV cards are now in the spare crate brought from Orsay. The detectors are polarised; network connection not working just yet. The leakage currents are as follows: |
Attachment 1: E860E1DA-73FB-4BF2-8A5D-CBF80580F0AC.jpeg
|
|
Attachment 2: D722B2E9-71F2-4C9E-BFB4-4ECEA1B84B45.jpeg
|
|
Fixed | e768s |
Thu Jul 18 22:10:58 2019 |
Jenn | OTHER | General | | Previous Papers |
|
Attachment 1: Proceedings_of_the_International_Conference_On_Nuclear_Reactions_Induced_by_Heavy_Ions_1970_Middleton.pdf
|
|
Attachment 2: Phys.Rev.C_2010_Fortune.pdf
|
|
Attachment 3: Phys.Rev.C_2003_Fortune.pdf
|
|
Attachment 4: Phys.Rev.C_1996_Mao.pdf
|
|
Attachment 5: Nucl.Phys.A_1996_de_Oliveira.pdf
|
|
Fixed | e768s |
Thu Jul 18 22:11:57 2019 |
Franco | OFFLINE | General | | Identification in Mugast |
Attached the spectra obtained in Mugast for run_0072_0_agata.root.
The colored ones are obtained simply asking for multiplicity 1, the black points are obtained
asking also for Z=9 (F) and for A=20 in VAMOS with the condition abs(mM_Q2*8-20)<0.5. |
Attachment 1: id_mugast_20Fblackpoints.png
|
|
Fixed | e768s |
Thu Jul 18 23:42:44 2019 |
mugast | RUN | General | | run 103 -> Brho scan |
|
Fixed | e768s |
Fri Jul 19 00:03:25 2019 |
Jenn | BEAM | General | | Brho information 15 Oxygen beam 4.7MeV/u |
|
Fixed | e768s |
Fri Jul 19 00:06:35 2019 |
Jenn | BEAM | General | | Brho information 15 Oxygen beam 4.7MeV/u |
|
Attachment 1: New_Doc_2019-07-18_23.58.18_1.pdf
|
|
Fixed | e768s |
Fri Jul 19 00:59:20 2019 |
mugast | RUN | General | | RUN 107 - Reference Target Run |
Reference Target Run after beam tuning
Brho 0.5854 Tm |
Fixed | e768s |
Fri Jul 19 01:02:54 2019 |
mugast | OTHER | General | | 15O beam parameters |
Brho manip = Brho after target - 2% = 0.556 Tm
RMN = 2821.476 Gauss
Q32 = 15.2 A
Q31 = 16.8 A
Q41 = 148.070 A
Q42 = 217.452 A
Dipole D4p = 187.632 A |
Fixed | e768s |
Fri Jul 19 01:05:26 2019 |
mugast | RUN | General | | RUN 108 |
Brho Change to 0.556 Tm
Moving Plate : Final Position +7mm
with 6 kHz
Slowly increasing |
Fixed | e768s |
Fri Jul 19 08:09:21 2019 |
Jenn, Kseniia | OTHER | General | | Overview nightshift run 112 |
Smooth night, everything was working properly.
Checked agata rootfile to see preliminary gammas.
19Ne 275 state observed
Also 19F (strong 109 state) (fusion-evaporation?)
Check Agata elog for more details. |
Fixed | e768s |
Fri Jul 19 15:11:10 2019 |
mugast | OFFLINE | General | | Procedure for run conversion and analysis |
Here is the procedure to convert a run with VAMOS and AGATA data and add those data to the Kinematic plot.
Every 4GB there will be a file change, to see if there is a file change type:
ls -ltrh /data/mugastX/e768s/acquisition/run/
Convert the last 4GB file and add it to the chain through the following steps:
Open a terminal from one of the Mugast computer:
Type: source $HOME/GoToVamosAna
Type: MyVAna -d2Ar -f /data/mugastX/e768s/acquisition/run/run_$$$$-DD-MM-YY.HHhMMmSSs /data/mugastX/e768s/acquisition/run/RootA/r$$$$_000a.root
OR (in case the run is split in more files)
Type: MyVAna -d2Ar -f /data/mugastX/e768s/acquisition/run/run_$$$$-DD-MM-YY.HHhMMmSSs.N /data/mugastX/e768s/acquisition/run/RootA/r$$$$_00Na.root
(If you get the error "Could not find the BrhoRef for the run <RunNr> ", update the ./Calibs/ListBrho.dat file with relevant Brho for RunNr)
Now you would be already able to run npanalysis to analyze the data VAMOS+Mugast with the following procedure:
Type: exit (to exit the VAMOS environment)
Type: lpcgrit (to load the analysis environment)
Type: npp MUGAST
Edit the exe_e768s.sh to specify which runs to analyze. The command should be the following:
npanalysis -D mugast.detector -C Calibration.txt -E ./Reaction/15N7Lit.reaction -T /data/mugastX/e768s/acquisition/run/RootA/r$$$$_00Na.root AD -O run_$$$$_N.root
Type: ./exe_e768s.sh
To convert a run including the AGATA data, the procedure is the following:
Go to the AGATA analysis computer (last on the right close to the window in the acquisition room), open a terminal and type the following commands:
> a4
> t e768s
> cd Replay
>./do_global_replay.sh -run ## (## is the number of the run you want to convert).
When it is finished, copy the root file to the GANIL world:
> mkdir /dataganil/e768s/acquisition/root_agata/run_00##/
> cp ./run_00##/Out/Analysis/Tree_00*.root /dataganil/e768s/acquisition/root_agata/run_00##/.
Now you can analyze the file using npanalysis.
The command in the exe_e768s.sh file should now look like:
npanalysis -D mugast.detector -C Calibration.txt -E ./Reaction/15N7Lit.reaction -T /data/mugastX/e768s/acquisition/root_agata/run_00##/Tree_000N.root TreeMaster -O run_00##_N_agata.root
The run will be created in the ./NPOutputs folder.
Bon courage! |
Fixed | e768s |
Fri Jul 19 15:55:38 2019 |
mugast | RUN | General | | Beam is fluctuating |
Run 115 stopped at 16h40. |
Attachment 1: VAMOS_MUGAST_IDENTIFICATION1.png
|
|
Attachment 2: run_115_scaler3.png
|
|
Attachment 3: run_115_scaler2.png
|
|
Attachment 4: run_115_scaler1.png
|
|
Attachment 5: run_115_IC_IC.png
|
|
Attachment 6: run_115_REC.png
|
|
Attachment 7: run_115_TAC.png
|
|
Attachment 8: run_115_IC2.png
|
|
Attachment 9: run_115_IC.png
|
|
Attachment 10: run_115_Ewire.png
|
|
Attachment 11: run_115_DCY.png
|
|
Attachment 12: run_115_DCXpng.png
|
|
Attachment 13: run_115_MM_MG_ERaw.png
|
|
Attachment 14: run_115_Tac.png
|
|
Attachment 15: run_115_MG_ToF.png
|
|
Attachment 16: run_115_MM_DeE.png
|
|
Attachment 17: run_115_MM_Tof.png
|
|
Attachment 18: run_115_MG_impact.png
|
|
Attachment 19: run_115_MM_impact.png
|
|
Fixed | e768s |
Fri Jul 19 17:33:21 2019 |
Nicolas | OTHER | General | | AGATA: what if a crystal status get red |
1. Go to the AGATA Digitizer: Control tab of the browser
2. Select the detector and crystal, then click 'Select'
3. Click the 'ReSync Current Digitizer Optical Link'
Normally it should go green again, otherwise call AGATA people |
Fixed | e768s |
Fri Jul 19 17:52:24 2019 |
Nicolas | OTHER | General | | AGATA: replaying runs |
1. Go to the AGATA analysis computer, open a terminal and execute the following commands:
> a4
> t e768s
> cd Replay
> ./do_global_replay.sh -run ### (### is the run number you want to convert)
if it complains that the folder with the run already exists, just > rm -rf runXXXX/ (where XXXX is the run you're replaying) in the Replay folder
2. When it is finished copy the root file to the GANIL world:
> mkdir /dataganil/e768s/acquisition/root_agata/run_0###
> cp ./run_0###/Out/Analysis/Tree_00*.root /dataganil/e768s/acquisition/run_0### |
Fixed | e768s |
Sat Jul 20 01:02:10 2019 |
Serge & Franco | OTHER | General | | Night shift beam & resync |
timeline of run 116
00:xx resync Agata #13C
00:57 lost beam, back at full intensity at 01:12
01:30 lost beam, back at full intensity at 01:45
01:37 FP_CATS5 tripped, reset
01:43 resync Agata #13C
02:04 resync Agata #13C
02:20 lost beam, back at full intensity at 02:30
02:36 resync Agata #13C
03:45 Vamos rate down to 900 pps, checked that intensity on profiler is 1.1e7 so decided to continue
05:58 resync Agata #13C
06:55 Vamos rate at 1400 pps but diamond is decreasing since several hours: we had 17500 counts at midnight and now only 7500.
Checked beam rate on profiler and found 1.8e7 so indeed it is the diamond efficiency that is going down steeply |
Fixed | e768s |
Sat Jul 20 05:58:18 2019 |
Franco | OFFLINE | General | | Time calibration for MG10_X |
Attached a tentative time calibration for the square MG10_X from run 89 (to be checked!).
Even applying the calibration the spectrum E_TOF for MG10 (run 115) displays many structures. |
Attachment 1: run_0089_MG10_timecal.png
|
|
Attachment 2: ETOF_MG10_run115.png
|
|
Fixed | e768s |
Sat Jul 20 08:01:06 2019 |
Nikola | ONLINE | General | | screenshots run 116 @ 08h00 |
|
Attachment 1: vamos_diamond.png
|
|
Attachment 2: scaler_run116.png
|
|
Attachment 3: mugast_run116_11.png
|
|
Attachment 4: mugast_run116_10.png
|
|
Attachment 5: mugast_run116_9.png
|
|
Attachment 6: mugast_run116_8.png
|
|
Attachment 7: mugast_run116_7.png
|
|
Attachment 8: mugast_run116_6.png
|
|
Attachment 9: mugast_run116_5.png
|
|
Attachment 10: mugast_run116_4.png
|
|
Attachment 11: mugast_run116_3.png
|
|
Attachment 12: mugast_run116_2.png
|
|
Attachment 13: mugast_run116_1.png
|
|
Attachment 14: vamos_run116_9.png
|
|
Attachment 15: vamos_run116_8.png
|
|
Attachment 16: vamos_run116_7.png
|
|
Attachment 17: vamos_run116_6.png
|
|
Attachment 18: vamos_run116_5.png
|
|
Attachment 19: vamos_run116_4.png
|
|
Attachment 20: vamos_run116_3.png
|
|
Attachment 21: vamos_run116_2.png
|
|
Attachment 22: vamos_run116_1.png
|
|
Fixed | e768s |
Sat Jul 20 09:20:35 2019 |
Nikola | ONLINE | General | | screenshots run 116 @ 09h20 |
|
Attachment 1: diamond_vamos_run116_2.png
|
|
Attachment 2: scaler_run116_2.png
|
|
Attachment 3: mugast_run116_2_1.png
|
|
Attachment 4: mugast_run116_2_2.png
|
|
Attachment 5: mugast_run116_2_3.png
|
|
Attachment 6: mugast_run116_2_4.png
|
|
Attachment 7: mugast_run116_2_5.png
|
|
Attachment 8: mugast_run116_2_6.png
|
|
Attachment 9: mugast_run116_2_7.png
|
|
Attachment 10: mugast_run116_2_8.png
|
|
Attachment 11: mugast_run116_2_9.png
|
|
Attachment 12: mugast_run116_2_10.png
|
|
Attachment 13: mugast_run116_2_11.png
|
|
Attachment 14: vamos_run116_2_1.png
|
|
Attachment 15: vamos_run116_2_2.png
|
|
Attachment 16: vamos_run116_2_3.png
|
|
Attachment 17: vamos_run116_2_4.png
|
|
Attachment 18: vamos_run116_2_5.png
|
|
Attachment 19: vamos_run116_2_6.png
|
|
Attachment 20: vamos_run116_2_7.png
|
|
Attachment 21: vamos_run116_2_8.png
|
|
Attachment 22: vamos_run116_2_9.png
|
|
Ongoing | |
Sat Jul 20 09:32:02 2019 |
Kseniia, Christian, Nikola, | OTHER | General | | summary of the morning shift |
timeline of run 116
09:15 resync AGATA crustal 13C, AGATA was in back-preassure for ~7 min
10:30 resync AGATA crustal 13C, AGATA was in back-preassure for ~3 min
10:40 run 116 stopped (PCP called, they have a problem with primary beam high intensity reader, they called in the on-call people) |
Fixed | e768s |
Sat Jul 20 10:50:01 2019 |
Nikola | ONLINE | General | | End of run 116 (beam problem) -> screenshots run 116 end @ 10h40 |
1. A monitor of the primary beam failed and the astreinte had to be call (PCP did it).
2. The H2O cold box went in default. The cold water for AGATA digitizer; vamos crates and CTA went up to 25 deg!
Reset..... waiting that it goes back to 17deg in the cave circuit |
Attachment 1: diamound_valos_run116_end.png
|
|
Attachment 2: scaler_run116_end.png
|
|
Attachment 3: vamos_run116_end_1.png
|
|
Attachment 4: vamos_run116_end_2.png
|
|
Attachment 5: vamos_run116_end_3.png
|
|
Attachment 6: vamos_run116_end_4.png
|
|
Attachment 7: vamos_run116_end_5.png
|
|
Attachment 8: vamos_run116_end_6.png
|
|
Attachment 9: vamos_run116_end_7.png
|
|
Attachment 10: vamos_run116_end_8.png
|
|
Attachment 11: vamos_run116_end_9.png
|
|
Attachment 12: mugast_run116_end_1.png
|
|
Attachment 13: mugast_run116_end_2.png
|
|
Attachment 14: mugast_run116_end_3.png
|
|
Attachment 15: mugast_run116_end_4.png
|
|
Attachment 16: mugast_run116_end_5.png
|
|
Attachment 17: mugast_run116_end_6.png
|
|
Attachment 18: mugast_run116_end_7.png
|
|
Attachment 19: mugast_run116_end_8.png
|
|
Attachment 20: mugast_run116_end_9.png
|
|
Attachment 21: mugast_run116_end_10.png
|
|
Attachment 22: mugast_run116_end_11.png
|
|