Status |
ExpNbr |
Date |
Author |
Type |
Category |
Target-Source |
Subject |
Fixed | e793s |
Tue Mar 9 10:22:16 2021 |
mugast | DAQ | Hardware | N/A | U2M scaler configuration |
U2M
1-FAG
2-OR MM-MG
3-OR AGATA
4-TRIG VAMOS
5-CATS CLEAN
6-DT && OR MM-MG
7-100 Hz
8-100 Hz & DT
9-MUVI1
10-MUVI2
11-MUVI3
12-MUVI4
15-CATS2 direct
16- FINGER (unused) |
Fixed | e793s |
Tue Mar 9 10:47:12 2021 |
mugast | DAQ | Hardware | N/A | GMT config |
GMT
1-MUVI1
2-MUVI2
3-MUVI3
4-
5-CATS2clean % (/10**4 for the moment)
6-VAMOS% (/10 for the moment)
7-MUST2% (/10 for the moment)
8-
9-
10-VAMOS
11-OR AGATA |
Fixed | com2019 |
Wed Apr 3 11:03:53 2019 |
Adrien Matta | CATS | Hardware | N/A | Cats mask will be shifted |
The propulsif supporting the cats mask is leaking.
It will be tighten to fix the leak, this lead to a small shift toward the left of the beam when looking at vamos. |
Fixed | com2019 |
Wed Apr 3 16:24:37 2019 |
Adrien | CATS | Software | N/A | Calib file from T.Roger |
Here are the calibration file provided by T. Roger. |
Attachment 1: CATS2_Y.vamos2019
|
0.00000e+00 0.00000e+00 0.00000e+00
2.71193e+02 3.51955e+01 9.20106e-01
2.54820e+02 3.85477e+01 1.02407e+00
2.70765e+02 9.63413e+01 1.01270e+00
2.38067e+02 -1.94775e+02 2.02755e+00
2.70950e+02 2.18371e+01 9.74726e-01
2.71165e+02 1.20869e+02 1.07928e+00
9.13653e+00 3.16800e+02 1.00754e+00
5.66055e+02 -2.33425e+02 9.05174e-01
2.87582e+02 4.24426e+01 9.10918e-01
2.71272e+02 3.51955e+01 9.20106e-01
2.87581e+02 1.47364e+01 9.01484e-01
2.87546e+02 6.66734e+00 9.93090e-01
2.05666e+02 1.43008e+02 9.85243e-01
3.03492e+02 0.00000e+00 1.00000e+00
3.03819e+02 -6.17854e+00 9.23957e-01
7.46067e+01 2.16790e+02 8.97818e-01
4.18173e+02 -1.88169e+01 8.82782e-01
2.70940e+02 6.14310e+01 8.89892e-01
2.38432e+02 9.12262e+01 8.87560e-01
2.38441e+02 7.85597e+01 8.77800e-01
2.38442e+02 8.48885e+01 8.70873e-01
2.22035e+02 1.14424e+02 8.95446e-01
2.54389e+02 8.12120e+01 8.90312e-01
2.21670e+02 1.59730e+02 9.33857e-01
2.70937e+02 7.20531e+01 8.66403e-01
5.82149e+01 2.32593e+02 8.43761e-01
2.87581e+02 -1.28631e+02 2.74796e+00
|
Attachment 2: CATS2_X.vamos2019
|
0.00000e+00 0.00000e+00 0.00000e+00
0.00000e+00 0.00000e+00 0.00000e+00
3.44896e+02 5.63680e+01 9.41419e-01
3.44871e+02 2.74924e+01 8.93518e-01
3.12042e+02 2.41995e+02 9.38371e-01
2.79148e+02 3.23114e+02 1.10331e+00
1.48358e+02 3.41540e+02 9.18807e-01
1.80540e+02 4.53841e+02 9.26752e-01
4.10458e+02 -5.02746e+01 9.52866e-01
3.44871e+02 -2.17129e+02 1.19034e+00
3.77669e+02 3.74782e+01 9.33222e-01
3.77669e+02 8.51246e+01 8.96266e-01
3.77644e+02 1.11250e+02 9.87395e-01
3.44871e+02 -1.76949e+01 9.49754e-01
3.77669e+02 0.00000e+00 1.00000e+00
3.77663e+02 7.06397e+01 9.18807e-01
2.13851e+02 1.68237e+02 9.52866e-01
3.11592e+02 2.51688e+02 9.15915e-01
2.79820e+02 1.11250e+02 9.87395e-01
2.46601e+02 1.27417e+02 1.03243e+00
2.79372e+02 1.46788e+02 8.79335e-01
2.79380e+02 2.32394e+02 8.93518e-01
3.12042e+02 1.81364e+02 9.23798e-01
2.79366e+02 1.00739e+02 9.18807e-01
2.46616e+02 1.03641e+02 9.03826e-01
2.46587e+02 1.39501e+02 9.36753e-01
3.44871e+02 2.12105e+02 9.11509e-01
2.79146e+02 1.51065e+02 2.75169e+00
|
Attachment 3: CATS1_Y.vamos2019
|
0.00000e+00 0.00000e+00 0.00000e+00
0.00000e+00 0.00000e+00 0.00000e+00
1.13931e+03 -3.52970e+02 9.68936e-01
8.44459e+02 -1.44555e+02 1.07619e+00
4.01828e+02 2.94406e+02 8.99414e-01
3.53072e+02 3.83002e+02 1.07128e+00
4.18602e+02 2.07103e+02 9.97538e-01
4.18604e+02 2.22703e+02 9.35567e-01
3.20322e+02 4.63142e+02 1.12991e+00
3.69469e+02 3.68467e+02 9.91268e-01
3.69466e+02 3.40471e+02 1.00655e+00
3.69533e+02 3.23507e+02 9.85421e-01
3.20391e+02 4.16747e+02 1.00459e+00
3.03942e+02 3.77691e+02 9.26262e-01
7.29833e+02 -1.81899e-12 1.00000e+00
3.36702e+02 4.72202e+02 1.07558e+00
3.20323e+02 5.25219e+02 1.01355e+00
2.71183e+02 3.20537e+02 8.57953e-01
3.20324e+02 4.53551e+02 9.49811e-01
2.38494e+02 5.25479e+02 9.09205e-01
3.20349e+02 4.37876e+02 8.58610e-01
4.18602e+02 3.18712e+02 9.32195e-01
3.85855e+02 2.52608e+02 9.56052e-01
4.34843e+02 2.54458e+02 9.89716e-01
4.50450e+02 1.87712e+02 8.76905e-01
3.20254e+02 8.14065e+02 1.60565e+00
3.53085e+02 2.57256e+02 9.52991e-01
0.00000e+00 0.00000e+00 0.00000e+00
|
Attachment 4: CATS1_X.vamos2019
|
0.00000e+00 0.00000e+00 0.00000e+00
0.00000e+00 0.00000e+00 0.00000e+00
1.40161e+02 9.92071e+01 9.76396e-01
1.89289e+02 -2.69023e+00 1.68488e+00
3.20343e+02 2.87366e+02 9.03085e-01
1.56522e+02 6.72206e+01 9.76396e-01
1.07402e+02 4.08998e+01 8.72104e-01
1.40150e+02 8.09504e+01 1.02684e+00
1.89310e+02 -5.35298e+01 1.48523e+00
3.20322e+02 -1.42885e+02 9.20481e-01
2.22045e+02 -2.12294e+01 1.00833e+00
1.23762e+02 4.60139e+01 8.42356e-01
1.40150e+02 1.46407e+02 1.09613e+00
2.70859e+02 -2.25241e+02 1.59755e+00
2.05264e+02 -9.09495e-13 1.00000e+00
2.71182e+02 -3.42651e+01 8.87728e-01
3.36702e+02 1.07801e+02 8.72316e-01
3.36720e+02 1.24392e+02 9.02291e-01
3.03966e+02 1.23800e+02 9.90423e-01
2.87562e+02 1.39729e+02 9.89467e-01
3.36702e+02 1.30358e+02 8.86667e-01
3.03668e+02 1.68313e+02 8.83800e-01
3.20254e+02 1.38346e+02 7.81607e-01
3.20392e+02 1.41100e+02 7.62264e-01
3.69438e+02 -1.65316e+02 1.32820e+00
3.53090e+02 8.71354e+01 7.81607e-01
3.36451e+02 9.07214e+01 7.77743e-01
2.87388e+02 1.41433e+02 6.18790e-01
|
Fixed | com2019 |
Fri Apr 5 14:54:09 2019 |
mugast | CATS | Hardware | N/A | CATS high voltage lowered by 20V |
CATS high voltage lowered by 20V from 580V to 560V (on request of J. Pancin) |
Fixed | com2019 |
Fri Apr 5 23:32:29 2019 |
Fairouz | CATS | General | CD2 | Electronic changes |
CATS detectors were removed.
For the MUVI stop, we send now HF propre.
The CATS1 signals sent to different TACS are now the HF signal |
Fixed | e744s |
Thu Apr 11 09:05:37 2019 |
mugast | CATS | General | N/A | CATS HV changed to 580 |
CATS HV changed from 600V to 580V. |
Fixed | e744s |
Thu Apr 11 14:03:45 2019 |
Valerian | CATS | Hardware | N/A | In case of a CATS2 tripped |
Currently, CATS2 is inserted, if the window :
CATS2 has tripped appear, one should do the following :
- Open a terminal
- Type: HV
- Username is : admin
- Password is : admin
- Press enter twice
The list of channels is going to appear.
- Using the arrow of the keyboard, go down until you reach cats2
- then go right until you reach Off
- press space, the dectector should start ramping up
- If it trips again, you can try to put voltage to cats1 (right above cats2)
Two possibility :
- If cats1 trip it is the gas bottle that is empty call : 07 83 34 30 81 (Sebastien)
- If cats1 doesn't trip try cats2 again, and if it trips lower the voltage of cats2
To lower the voltage of cats2 : go to the left until you reach the first cell after cats2 name and lower the voltage 10 volts and try to start cats2 again.
THEN CLOSE THE TERMINAL |
Fixed | e744s |
Thu Apr 11 15:16:10 2019 |
Adrien, Valerian, Louis | CATS | General | CH2 | run77 CATS efficiency |
CATS efficiency has been computed for run 77 using T_FagHF an T_Si_Cats1 with different triggers:
Trigger GATCONF_MASTER<8 (MUST+Mugast) : 94%
Trigger GATCONF_MASTER=4 (MUST) : 99.4%
Trigger GATCONF_MASTER=2 (square) : 85%
Trigger GATCONF_MASTER=1 (trapezoidal+annular) : 22%
The 22% resolution is due to the fact that the trapezoidal detectors are noisy. Doing the same on an analysed run we obtain ~ 85% efficiency |
Fixed | e744s |
Fri Apr 12 02:19:02 2019 |
Francois, Jenn, Cyril, Louis | CATS | Hardware | N/A | Set Division for CATS and Agata |
Enter in G1 to set division on CATS and Agata
CATS divion: 1000
Agata division: 100
|
Fixed | e744s |
Tue Apr 16 08:23:38 2019 |
Marion, Dieter | CATS | Hardware | CH2 | CATS tripping - lowering bias |
8:24 Faraday in.
-5V on CATS.
550V.
8:25 Faraday out |
Fixed | e744s |
Tue Apr 16 11:40:04 2019 |
mugast | CATS | Hardware | N/A | CATS HV |
CATS2 HV was decreased to 540 V at 11h30 to avoid the overcurrent.
Need to monitor Efficiency, Time resolution as soon as the run restart with new target. |
Fixed | e786s |
Wed Jun 26 07:04:06 2019 |
Freddy | CATS | General | N/A | Update of CATS calibrations |
New calibrations in :
/home/mugast/analysis/nptool/Projects/calibration/cats/CATS2_X.vamos2019_e786s.npt
/home/mugast/analysis/nptool/Projects/calibration/cats/CATS2_X.vamos2019_e786s.npt
Calibration.txt was modified accordingly.
Attached are the CATS positions for run 56 and 58 (after the central strip problem) |
Attachment 1: run56_cats_newcal.png
|
|
Attachment 2: run_58_cats_newcal.png
|
|
Fixed | e786s |
Fri Jun 28 08:57:21 2019 |
Freddy | CATS | General | Cryo-3He | CATS scaler not compatible with beam rate |
The CATS scaler si now around 100-120 kHz while the beam rate is still 40 kHz.
I checked the CATS signal and there is clearly noise who induce double logic signals. Not all of them are validated by FAG.
We should raise the threshold- call sebastien
9h32 : Stop beam to enter and raise the threshold. |
Attachment 1: ScalerCATSproblem.png
|
|
Fixed | e793s |
Thu Mar 11 04:34:58 2021 |
ablaihan, louis | CATS | Hardware | CD2 | CATS and VAMOS tripped |
at 4h15 CATS and VAMOS tripped probably due to too high beam intensity (~1.2x10^6 pps). We switched them on again at 4h30. All the 6 CATS in Board2 in HV by 525 V instead of 530 V.
We did not stop the run to not risk to crash the RCC. Events btw 4h15 and 4h30 will therefore have no time. |
Attachment 1: Scaler_run53_4h30.png
|
|
Fixed | e744s |
Wed Apr 10 06:45:53 2019 |
François | BEAM | Social | | No beam yet |
They are about to align the beam from the cyclotron CIME to the area G1. |
Fixed | e744s |
Wed Apr 10 06:51:35 2019 |
Beyhan | BEAM | General | | 14N7+ beam characteristics and settings at VAMOS |
|
Attachment 1: IMG_1552.jpg
|
|
Attachment 2: IMG_1549.jpg
|
|
Attachment 3: IMG_1550.jpg
|
|
Attachment 4: IMG_1553.jpg
|
|
Fixed | e744s |
Wed Apr 10 07:15:22 2019 |
François | BEAM | Social | | no beam |
They aligned the beam up to G1 Pr31 but the stripper foil was not inserted, so they have to start the work again. |
Fixed | e744s |
Wed Apr 10 09:05:33 2019 |
François | BEAM | Social | | No beam in G1 yet. |
The beam is at the entrance of G1. |
Fixed | e744s |
Wed Apr 10 10:15:38 2019 |
François | BEAM | Social | | Beam stopped |
A problem with the cooling water.
2 UT at least to restart the accelerator |