Fixede793s Fri Mar 12 02:01:52 2021 Taras, Nishu, Chloe, CharlieRUNGeneralCD2run56 screenshots at 02h10
screenshots of run 56 attached below
Attachment 1: run-56_screenshot.png
run-56_screenshot.png
Attachment 2: vamos_screenshot.png
vamos_screenshot.png
Attachment 3: run56_MG-IMPACT_MATRIX_02h10.png
run56_MG-IMPACT_MATRIX_02h10.png
Attachment 4: run56_MM_ToF_02h10.png
run56_MM_ToF_02h10.png
Attachment 5: run56_MM_DeE_02h10.png
run56_MM_DeE_02h10.png
Attachment 6: run56_MG_ToF_02h10.png
run56_MG_ToF_02h10.png
Attachment 7: run56_TAC_02h10.png
run56_TAC_02h10.png
Attachment 8: run56_MM_TX_02h10.png
run56_MM_TX_02h10.png
Attachment 9: run56_MM_TY_02h11.png
run56_MM_TY_02h11.png
Attachment 10: run56_ELab_ThetaLab_02h10.png
run56_ELab_ThetaLab_02h10.png
Fixede793s Fri Mar 12 03:21:01 2021 Taras, Chloe, NIshu, CharlieVAMOSGeneralCD2VAMOS trip, requires help (FIXED @ 03:55)
We received a call from PCP telling us that VAMOS has tripped. Currents on all focal planes are 0. We tried stopping and restarting the FP_CATS0 - FP_CATS5, but this does not resolve the issue.

A picture of the VAMOS control screen is attached. Diego has been contacted.

EDIT:::
Diego has informed us that the focal plane current is not the issue. The problem instead is with G1.G.D4.P (dipole?) in VAMOS. This has tripped off (see second attached image). He has advised us to call Bertrand to fix this.

EDIT2:::
Bertrand called an operator, and the VAMOS count rate is now back up to normal. The whole process from crash to fix took ~half an hour
Attachment 1: PXL_20210312_020550869.jpg
PXL_20210312_020550869.jpg
Attachment 2: PXL_20210312_024401845.jpg
PXL_20210312_024401845.jpg
Fixede793s Fri Mar 12 03:57:46 2021 Taras, Nishu, Chloe, CharlieVAMOSGeneralCD2dipole issue fixed
the alimentation on dipole (G1.G.D4.P) was turned off,
the value was resetted(322.6) and works fine now.
cour: 323.5 A
tens. 39.21 V
Attachment 1: run56_dipolefixed.png
run56_dipolefixed.png
Fixede793s Fri Mar 12 04:19:51 2021 Taras, Nishu, Chloe, CharlieRUNGeneralCD2run56 screenshots at 04h18
Images attached.
Attachment 1: run56_Scalers_04h14.png
run56_Scalers_04h14.png
Attachment 2: run56_MG-IMPACT_MATRIX_04h15.png
run56_MG-IMPACT_MATRIX_04h15.png
Attachment 3: run56_MM_ToF_04h15.png
run56_MM_ToF_04h15.png
Attachment 4: run56_MM_DeE_04h15.png
run56_MM_DeE_04h15.png
Attachment 5: run56_MG_ToF_04h15.png
run56_MG_ToF_04h15.png
Attachment 6: run56_TAC_04h15.png
run56_TAC_04h15.png
Attachment 7: run56_MM_RawX_04h10.png
run56_MM_RawX_04h10.png
Attachment 8: run56_MM_RawY_04h10.png
run56_MM_RawY_04h10.png
Attachment 9: run56_MM_TX_04h10.png
run56_MM_TX_04h10.png
Attachment 10: run56_MM_TY_04h11.png
run56_MM_TY_04h11.png
Attachment 11: run56_FSC_04h12.png
run56_FSC_04h12.png
Attachment 12: run56_VAMOS_MW_04h20.png
run56_VAMOS_MW_04h20.png
Attachment 13: run56_MM_IMPACT_MATRIX_04h20.png
run56_MM_IMPACT_MATRIX_04h20.png
Attachment 14: run56_ELab_ThetaLab_04h10.png
run56_ELab_ThetaLab_04h10.png
Fixede793s Fri Mar 12 06:23:44 2021 Taras, Nishu, Chloe, CharlieRUNGeneralCD2run56 screenshots at 06h15
Screenshots attached
Attachment 1: run56_Scalers_06h14.png
run56_Scalers_06h14.png
Attachment 2: run56_MG-IMPACT_MATRIX_06h15.png
run56_MG-IMPACT_MATRIX_06h15.png
Attachment 3: run56_MM_ToF_06h15.png
run56_MM_ToF_06h15.png
Attachment 4: run56_MM_DeE_06h15.png
run56_MM_DeE_06h15.png
Attachment 5: run56_MG_ToF_06h15.png
run56_MG_ToF_06h15.png
Attachment 6: run56_TAC_06h15.png
run56_TAC_06h15.png
Attachment 7: run56_FSC_06h12.png
run56_FSC_06h12.png
Attachment 8: run56_VAMOS_MW_06h20.png
run56_VAMOS_MW_06h20.png
Attachment 9: run56_MM_IMPACT_MATRIX_06h20.png
run56_MM_IMPACT_MATRIX_06h20.png
Attachment 10: run56_ELab_ThetaLab_06h10.png
run56_ELab_ThetaLab_06h10.png
Fixede793s Fri Mar 12 08:58:09 2021 AdrienBEAMHardwareCD2Beam is stopped 8h55
Beam stopped to fix a leak on the accelerator. Intervention up to 4hours, maybe less.
Fixede793s Fri Mar 12 09:52:01 2021 mugast (Sarah, Louis)OFFLINEGeneralCD2Offline analysis run up to 56 8am
1) A high energy gamma has been identified at 3505 keV by gating on 3-5 MeV range in excitation energy. This transition is unknown so far

2) preliminary angular distribution has been extracted for the p states(<1MeV) and the f states (3-5MeV) corrected from geometrical efficiency. Angular distribution with gate on the 3.5 MeV gamma was also extracted. Too few statistics to tell anything. Need at least 4 time more statistics to have a proper angular distribution.
Attachment 1: AngDisrtib.png
AngDisrtib.png
Attachment 2: 3MeV_gamma.png
3MeV_gamma.png
Attachment 3: AWBA.png
AWBA.png
Fixede793s Fri Mar 12 09:55:30 2021 FrancoGRITGeneralCD2MM5
The first plot attached has been done by artificially removing 7 deg in theta lab, just to see if the the kinematic lines of 47K(d,d) and 47K(p,p) can be reproduced. Of course the energy losses are not optimized in this case but anyway the agreement seems nice.
In the second plot I moved MM5 forward (in z) by 17.5 mm, without any re-orientation in x and y. We should compare this position with the one measured by the surveyors.
It looks like we have plenty of protons in the target but actually the Rutherford cross section at 80 deg for (p,p) is 4 times higher than the (d,d) one. From a quick estimation the ratio 2H:1H in the target should be around 3:1 (to be checked!).
Attachment 1: square_shifted_theta.png
square_shifted_theta.png
Attachment 2: square_shifted_Z.png
square_shifted_Z.png
Fixede793s Fri Mar 12 09:57:30 2021 AdrienOTHERSocialN/ALost phone in agata counting room
Someone lost his/her phone in the agata counting room. Pictures attached.
Attachment 1: 161C9D73-3ED8-49DE-A1EF-4ED9AA11C912.jpeg
161C9D73-3ED8-49DE-A1EF-4ED9AA11C912.jpeg
Fixede793s Fri Mar 12 10:07:29 2021 mugastMECHHardware Leak

https://www.hometree.co.uk/energy-advice/home-cover/common-water-leaks-and-how-to-fix-them.html
Fixede793s Fri Mar 12 10:32:41 2021 OttoRunRUNGeneralCD2Run57
*************************
Run : 57
*************************

Start at 2021-03-12 10:32:22.121271

Test run. ACQ DT

(ATC6 crystal stopped)
New beam tune with better centering from Bertrand

Beam: 3.5e5 pps
target: CD2 0.5mg
Trigger are MUGAST/MM/CATS%

Stop at 2021-03-12 11:12:37.613523
Stop comment: type your message here
Fixede793s Fri Mar 12 10:52:46 2021 AdrienVAMOSHardwareN/AQ pole trip in vamos
Q-Pole tripped this night around 4am at the same time as the dipole but was switch on again only at 9am.
Ongoinge793s Fri Mar 12 12:58:10 2021 Emmanuel COFFLINEGeneral Gamma Gamma Analysis
Attachment 1: 48K.pdf
48K.pdf
Attachment 2: e793s_1.png
e793s_1.png
Attachment 3: e793s_142Gated.png
e793s_142Gated.png
Attachment 4: e793s_280Gated.png
e793s_280Gated.png
Attachment 5: e793s_451Gated.png
e793s_451Gated.png
Attachment 6: e793s_1842Gated.png
e793s_1842Gated.png
Attachment 7: e793s_3523Gated.png
e793s_3523Gated.png
Fixede793s Fri Mar 12 13:40:59 2021 OttoRunRUNGeneralCD2Run59
*************************
Run : 59
*************************

Start at 2021-03-12 13:40:31.431982

Test run. ACQ DT

(ATC6 crystal stopped)
starting again after beam line reparation of power supply

Beam: 3.5e5 pps
target: CD2 0.5mg
Trigger are MUGAST/MM/CATS%

Stop at 2021-03-12 13:42:17.319503
Stop comment: stopping daq because agata daq did not start
Fixede793s Fri Mar 12 15:19:35 2021 OttoRunRUNGeneralCD2Run60
*************************
Run : 60
*************************

Start at 2021-03-12 15:19:14.732769

Test run. ACQ DT

ATC6 pos 0 is back
14C is removed
starting again after beam line reparation of power supply

Beam: 3.5e5 pps
target: CD2 0.5mg
Trigger are MUGAST/MM/CATS%

Stop at 2021-03-12 16:53:37.438208
Stop comment: stop run after tuning of the beam
Pinnede793s Fri Mar 12 15:48:35 2021 AdrienRUNGeneralN/AVamos D and Q value and MW HV
Pinnede793s Fri Mar 12 15:50:12 2021 AdrienRUNGeneralN/AVamos D and Q value and MW HV
Attached are the value for D and Q pole of vamos in case they trip.
Also attached is the computer driving the HV of the focal plan.
Attachment 1: 1613EC0C-1F4A-4933-B90A-D98A37421BFF.jpeg
1613EC0C-1F4A-4933-B90A-D98A37421BFF.jpeg
Attachment 2: 4ACA3448-35FF-472C-977C-E642B4ADE6A6.jpeg
4ACA3448-35FF-472C-977C-E642B4ADE6A6.jpeg
Fixede793s Fri Mar 12 15:52:15 2021 AdrienRUNGeneralN/Ato do during run
Every 1-2h:

Online: take screen shot of
  • Impact Matrix (MM and MG)
  • E-TOF (MM and MG)
  • E-DE (MM and MG)
  • Raw Tac
  • MW TDC
  • Scaler

Check the Vamos Q and D value on the left computer in the VAMOS daq ROOM (next to inspection line)
Fixede793s Fri Mar 12 16:58:43 2021 OttoRunRUNGeneralCD2Run61
*************************
Run : 61
*************************

Start at 2021-03-12 16:57:56.722818

Test run. ACQ DT


starting again after centering the beam on the target

Beam: 3.5e5 pps
target: CD2 0.5mg
Trigger are MUGAST/MM/CATS%

Stop at 2021-03-13 07:09:09.949615
Stop comment: run 61 stopped to fix AGATA acquisition problem
Fixede793s Fri Mar 12 18:42:51 2021 Sarah, LouisBEAMGeneralCD2Beam Back
The beam is back at 18h40
The beam stopped due to source problems, going up steadily, currently at ~2e5 pps