Status |
ExpNbr |
Date |
Author |
Type |
Category |
Target-Source |
Subject |
Fixed | e793s |
Sat Mar 6 13:25:38 2021 |
OttoRun | RUN | General | 3-alpha | Run630 |
*************************
Run : 630
*************************
Start at 2021-03-06 13:15:07.038908
run 3 alpha. time calibrator is on but is not giving any trigger so just sending random stop
Stop at 2021-03-08 09:50:00.232468
Stop comment:
Stop at 2021-03-08 15:28:10.213189
Stop comment:
Stop at 2021-03-08 15:28:10.881754
Stop comment:
Stop at 2021-03-08 15:28:11.447832
Stop comment: |
Fixed | e793s |
Mon Mar 8 08:45:49 2021 |
Adrien | OFFLINE | General | N/A | TO DO LIST for 8 march 2021 |
Here is a todo list for today:
Data conversion:
- Raw run files are located in /data/mugastX/mugast/acquisition/run/
- Converting FSC run: 622 to 629 : run_0630.dat.06-03-21_13h15m06s
- Converting alpha run: 630. warning: there is 3 files for this run :run_0630.dat.06-03-21_13h15m06s and run_0630.dat.06-03-21_13h15m06s.1 and run_0630.dat.06-03-21_13h15m06s.2
Extract histogram for calibration: each macro need to be run twice, once for MUGAST and once for MUST2 if I remember correctly.
- Extract histograms for FSC run with the macro located : /home/mugast/analysis/nptool/Projects/calibration/Time/ExtractRawHisto_T.C
- Extract histograms for alpha run with the macro located : /home/mugast/analysis/nptool/Projects/calibration/Energy/ExtractRawHisto_E.C
Analysed the extracted histograms to calibrate: change the appropriate field in the macro before running
- FSC: /home/mugast/analysis/nptool/Projects/calibration/Time/TimeCalibrator.C
- alpha: /home/mugast/analysis/nptool/Projects/calibration/Energy/EnergyCalibrator.C
Prepare the calibration file to be used for the online/offline analysis:
- List all the file you just generated in /home/mugast/analysis/nptool/Projects/MUGAST/Calibration.txt
- Do some cleanup in the file so it is more readable.
- Check for missing/noisy strips and adjust config file in /home/mugast/analysis/nptool/Projects/MUGAST/configs
Analysed the calibration run with the new calibration:
- check T:strip and E:strip
- Post a summary of the resolution for each detector
Time calibrator on all tac
- Check the range of each tac
- wired the start/stop to the TAC inputs
- do an acquisition with enough statitics
- analyse it and put the calibration file in Calibration.txt
|
Fixed | e793s |
Mon Mar 8 17:21:14 2021 |
mugast | GRIT | General | N/A | Run631 - TACs calibration (part 1) |
*************************
Run : 631
*************************
Start at 2021-03-08 17:19:55.467916
TAC calibration.
- FAG-CATS2 (range 500 ns)
- Vamos-Agata (range 500 ns)
- CATS2-CATS2 (not in modular label) (range 500 ns)
Time calibrator
|
Fixed | e793s |
Mon Mar 8 17:47:29 2021 |
mugast | GRIT | General | N/A | Run632 - TACs calibration (part 2) |
TAC calibration.
VAMOS-CATS2 (range 2 us)
Mugast-VAMOS (range 2 us )
Mugast-AGATA (range 2 us)
Time calibrator
2.56 us range
40 ns steps |
Fixed | e793s |
Mon Mar 8 18:07:25 2021 |
mugast | GRIT | General | N/A | Run 633 - TACs calibration (part 3) |
TAC calibration.
Mugast-CATS2 (range 1 us)
Mugast-CATS2b (range 2 us)
AGATA-CATS2 (for this one better to use run 634)
Time calibrator
2.56 us range
40 ns steps |
Fixed | e793s |
Mon Mar 8 18:15:07 2021 |
mugast | GRIT | General | N/A | Run 634 - TACs calibration (part 4) |
TAC calibration.
AGATA-CATS2 (range 200 ns)
Time calibrator
2.56 us range
10 ns steps |
Fixed | e793s |
Mon Mar 8 19:01:26 2021 |
Franco | GRIT | General | 3-alpha | Energy and time calibrations before experiment |
Energy resolutions:
MG1: 45 keV
MG2: 45 keV
MG3: 45 keV
MG4: 50 keV
MG5: 50 keV
MG7: 50 keV
Total Mugast: 50 keV
MM1: 50 keV
MM2: 50 keV
MM3: 45 keV
MM4: 50 keV
Total MUST2: 50 keV
MM5 (90 deg): 65 keV |
Attachment 1: Mugast_Eraw_run630.png
|
|
Attachment 2: MUST2_Eraw_run630.png
|
|
Attachment 3: Mugast_Traw_fsc.png
|
|
Attachment 4: MUST2_Traw_fsc.png
|
|
Attachment 5: Mugast_Ecal_run630.png
|
|
Attachment 6: MUST2_Ecal_run630.png
|
|
Attachment 7: Mugast_Tcal_fsc.png
|
|
Attachment 8: MUST2_Tcal_fsc.png
|
|
Pinned | e793s |
Tue Mar 9 09:35:18 2021 |
Adrien | OTHER | General | N/A | E793s proposal |
Attached is the proposal of the experiment. |
Attachment 1: Proposal_K48_by_dp_MUGAST_FINAL.pdf
|
|
Fixed | e793s |
Tue Mar 9 09:43:51 2021 |
OttoRun | RUN | General | 3-alpha | Run200 |
*************************
Run : 200
*************************
Start at 2021-03-08 17:43:53.831102
run 3 alpha
Stop at 2021-03-09 09:43:55.629095
Stop comment: type your message here
Stop at 2021-03-09 09:43:56.774034
Stop comment: type your message here
Stop at 2021-03-09 09:43:57.137511
Stop comment: type your message here
Stop at 2021-03-09 09:43:57.480913
Stop comment: type your message here |
Fixed | e793s |
Tue Mar 9 11:47:14 2021 |
Franco | RUN | General | N/A | TACS calibration |
Coefficients uploaded in MUGAST/e793s/calibTACS_e793s.cal (set offsets to 0 and kept only the slope) |
Attachment 1: TACS_calib.png
|
|
Attachment 2: TACS_calib_fits.png
|
|
Fixed | e793s |
Wed Mar 10 13:03:00 2021 |
OttoRun | RUN | General | 3-alpha | Run41 |
*************************
Run : 41
*************************
Start at 2021-03-10 12:58:41.805693
run 3 alpha
Stop at 2021-03-10 13:06:49.699879
Stop comment: |
Fixed | e793s |
Wed Mar 10 13:09:12 2021 |
OttoRun | RUN | General | 3-alpha | Run42 |
*************************
Run : 42
*************************
Start at 2021-03-10 13:09:04.739262
run 3 alpha
Stop at 2021-03-10 13:30:31.317348
Stop comment: changing trigger |
Pinned | e793s |
Wed Mar 10 13:10:14 2021 |
Adrien | BEAM | General | CD2 | Kinematical line from Ti contamination |
In black the Kinematical line for states known to be populated strongly in 47Ti(d,p).
In blue range of the states of interrest.
The contamination is in a different region and should not cause any issue. |
Attachment 1: KineTiK.pdf
|
|
Attachment 2: Kine.cxx
|
void AddTiStates(double E);
void Kine(){
NPL::Reaction K("47K(d,p)48K@362");
// K states
auto g = K.GetKinematicLine3();
g->SetLineColor(kAzure+7);
g->SetLineWidth(3);
g->Draw("ac");
K.SetExcitationHeavy(4);
g = K.GetKinematicLine3();
g->SetLineColor(kAzure+7);
g->SetLineWidth(2);
g->SetLineStyle(1);
g->Draw("c");
AddTiStates(0);
AddTiStates(0);
AddTiStates(0.969);
AddTiStates(2.2292);
AddTiStates(2.419);
AddTiStates(3.223);
AddTiStates(3.332);
AddTiStates(3.622);
AddTiStates(4.388);
AddTiStates(4.458);
AddTiStates(4.719);
AddTiStates(4.852);
AddTiStates(5.151);
}
void AddTiStates(double E){
NPL::Reaction Ti("47Ti(d,p)48Ti@362");
// Ti states
Ti.SetExcitationHeavy(E);
auto g = Ti.GetKinematicLine3();
g->SetLineWidth(1);
g->SetLineStyle(2);
g->Draw("c");
}
|
Fixed | e793s |
Wed Mar 10 13:33:31 2021 |
OttoRun | RUN | General | N/A | Run43 |
*************************
Run : 43
*************************
Start at 2021-03-10 13:33:01.346673
Agata or as trigger for testing before beam
Stop at 2021-03-10 13:55:37.322216
Stop comment: |
Fixed | e793s |
Wed Mar 10 13:57:54 2021 |
OttoRun | RUN | General | N/A | Run45 |
*************************
Run : 45
*************************
Start at 2021-03-10 13:57:50.701600
Agata or as trigger for testing before beam
Stop at 2021-03-10 14:01:53.157232
Stop comment: |
Fixed | e793s |
Wed Mar 10 14:43:14 2021 |
OttoRun | RUN | General | N/A | Run46 |
*************************
Run : 46
*************************
Start at 2021-03-10 14:42:50.365714
Test run for Professor Clement. Beam in the room.
Stop at 2021-03-10 16:02:30.981195
Stop comment: |
Fixed | e793s |
Wed Mar 10 15:15:44 2021 |
Charlie | OTHER | General | | 48Ti Kinematics (additional) |
Supplementary to Adrien's kinematic calculations of 47Ti(d,p)48Ti, we have found a paper suggesting that by far the most strongly populated state in 48Ti is at 5.65 MeV. There is also a doublet of strong states at around 4.4 MeV, and two more strongly populated states at 6.06 and 6.33 MeV.
See attachment for the full table from P. D. Barnes (1965), Phys.Rev.138.B597.
Some quick CatKin models also show that a (theoretical) state at 7 MeV in 48Ti would almost perfectly overlap with the ground state of 48K. As such, when looking at the lab energy with the g.s. of 48K normalised to 0, we could expect to see these strongly populated 48Ti states at -0.67, -0.94, -1.35 and -2.6 MeV (for 6.3, 6.06, 5.65 and 4.4 MeV, respectively).
See the attached plot for kinematics of 47K(d,p)48K @ 0 MeV and 4 MeV, as well as 47Ti(d,p)48Ti @ 0 MeV, 5.65 MeV and the theoretical 7 MeV. Additionally, see a mock-up of the expected spectra from Wilton. |
Attachment 1: PDBarnes_Table_1.png
|
|
Attachment 2: 48Ti_and_48K_Kinematics.png
|
|
Attachment 3: Wilton_mock-up.png
|
|
Fixed | e793s |
Wed Mar 10 16:07:43 2021 |
OttoRun | RUN | General | N/A | Run47 |
*************************
Run : 47
*************************
Start at 2021-03-10 16:07:22.660368
Beam in the room; restarting daq after recompiling the action
Stop at 2021-03-10 16:09:55.182936
Stop comment: stopping run to remove vamos% from trigger |
Fixed | e793s |
Wed Mar 10 16:12:40 2021 |
OttoRun | RUN | General | Empty | Run48 |
*************************
Run : 48
*************************
Start at 2021-03-10 16:11:56.052849
Beam in the room; restarting daq after changing trigger.
Trigger are MUGAST/MM/CATS%
Stop at 2021-03-10 16:30:03.651340
Stop comment: stopping to remove cats% from trigger so we can set the timing |
Fixed | e793s |
Wed Mar 10 16:31:50 2021 |
OttoRun | RUN | General | CD2 | Run49 |
*************************
Run : 49
*************************
Start at 2021-03-10 16:31:31.923710
Beam in the room; restarting daq after changing trigger.
target: CD2 0.5mg
Trigger are MUGAST/MM
Stop at 2021-03-10 16:53:12.237279
Stop comment: stopping to change GMT windows |