MUST2
SAMURAI_2018
S3-LEB-LPC
SUPERNEMO
MUGAST
EXPAND
SCALP
GALATRON
HiCARI
VELO
MUGAST, Page 123 of 132
Not logged in
Find
|
Login
Full
| Summary |
Threaded
2636 Entries
Goto page
Previous
1
,
2
,
3
...
122
, 123,
124
...
130
,
131
,
132
Next
Status
ExpNbr
Date
Author
Type
Category
Target-Source
Subject
Text
Fixed
e768s
Mon Jul 22 17:54:49 2019
Christian and Jeremie
AGATA
General
LiF
Comparison EGamma 19Ne, Q8 vs Q9
1) Beam velocity from VAMOS for AGATA doppler
correction. Beta is understandable for the
three main charge states seen (with Q9 and
Fixed
com2019
Tue Apr 2 16:24:06 2019
marlene freddy
OTHER
General
N/A
Commissioning proposal
Fixed
e768s
Mon Jul 22 16:54:33 2019
Marlène, Franck, François & Nicolas
BEAM
General
Cheking beam transmission from G1 profiler to VAMOS
Goal:
Estimate beam transmission from profiler
to VAMOS (FP)
Fixed
e768s
Tue Jul 23 14:33:03 2019
Marlène, Yorick, Faïrouz & Nicolas
BEAM
General
Cheking beam transmission from G1 profiler to VAMOS
Goal:
Estimate beam transmission from profiler
to VAMOS (FP)
Fixed
com2019
Mon Apr 8 10:58:16 2019
Adrien
OFFLINE
General
CD2
Checked alignement of the different Silicon at backward angle
Here is a plot of Ex for all the com. stats
detector by detector.
Fixed
e768s
Tue Jul 30 07:49:09 2019
Teodora & Franco
RUN
General
LiF
Check beam intensity and profile run158 h 8:00
Fixed
e768s
Fri Jul 26 23:58:08 2019
Andres & Franco
RUN
General
LiF
Check beam intensity and profile run152 h 23.40
Fixed
e768s
Fri Jul 26 19:47:18 2019
Andres & Franco
RUN
General
LiF
Check beam intensity and profile run152 h 19.30
Fixed
e744s
Thu Apr 11 02:54:09 2019
mugast
RUN
General
Changing Brho to 0.51 Tm starting run 70
Fixed
e793s
Tue Mar 10 18:46:13 2020
Franco & Marlène
GRIT
Hardware
Changes in MUGAST
- MG6 (FZ) is disconnected.
- MG7 (500um) is dismounted and MG8 (375um)
is replacing it.
Fixed
TEST
Wed Jan 22 15:53:25 2020
Marlène
GRIT
Hardware
Changes for MUGAST2020
Changes were made for MUGAST 2020 :
1- the board for MG10 before (2nd square)
is now for MG6 new trap
Fixed
e744s
Thu Apr 11 19:19:21 2019
Iulian Beyhan
RUN
General
N/A
Change target CH2 to no target
Target hole is now removed -> No target
Fixed
e744s
Sun Apr 14 15:05:06 2019
A. Lemasson
VAMOS
Hardware
Change of Offset in DC Numexo
[LIST]
[*] Increasing offset to minimize saturation.
Fixed
Wed Jan 23 12:24:10 2019
Marlène
GRIT
General
Change cable MG1T - Exchange of detectors named MG9C & MG10C
23/01/19
Change of the HT/BT cable of MG1T (the one
Fixed
e793s
Mon Mar 15 10:18:37 2021
Taras, cyril, Léo
ONLINE
Hardware
CD2
Cats2 tripped
Cats2 tripped with vamos, had to be reset
Beam is back
Fixed
com2019
Wed Apr 3 11:03:53 2019
Adrien Matta
CATS
Hardware
N/A
Cats mask will be shifted
The propulsif supporting the cats mask is
leaking.
Fixed
TEST
Fri Jan 18 15:32:50 2019
Adrien Valérian
GRIT
General
N/A
Calimero tests Muvi2 MM7 MG10C
After disabling nptool Multithreading, online
is working fine again.
Fixed
TEST
Wed Jan 16 17:36:30 2019
Valérian-Marlène
GRIT
General
N/A
Calimero tests - How to configure Calimero in GECO
Tests of Calimero time calibration with MUVI1
channel 2 (MM2)
Fixed
TEST
Tue Mar 5 15:53:04 2019
iulian Marlene
MUST2
Software
N/A
Calimero problems
problems with Calimero solved by killing some
processes on lpcgrit related with Narval.
to find the processes on lpcgrit:
Fixed
TEST
Tue Mar 5 18:03:24 2019
iulian Marlene
MUST2
Software
N/A
Calimero problem on Y side
Calimero not working properly on Y side of
any mm detector
Goto page
Previous
1
,
2
,
3
...
122
, 123,
124
...
130
,
131
,
132
Next
ELOG Home Page