MUST2
SAMURAI_2018
S3-LEB-LPC
SUPERNEMO
MUGAST
EXPAND
SCALP
GALATRON
HiCARI
VELO
MUGAST, Page 122 of 132
Not logged in
Find
|
Login
Full
| Summary |
Threaded
2636 Entries
Goto page
Previous
1
,
2
,
3
...
121
, 122,
123
...
130
,
131
,
132
Next
Status
ExpNbr
Date
Author
Type
Category
Target-Source
Subject
Text
Fixed
Fri Apr 5 19:05:56 2019
Marlène Nicolas
GRIT
General
Brho beam & 17O
Brho of 16O @ 6 MeV/A after 1mg/cm2 = 0.68906
Brho of 17O for g.s. after 1 mg/cm2=0.71065
Brho of 17O @ 871 keV after 1mg/cm2=0.70831
Fixed
com2019
Sat Apr 6 02:48:39 2019
Iulian Ruxandra
RUN
Software
Online Spectra run 256 @2h30 am 06/04 (for reference)
The online spectra (for reference)
No timing on Mg3 & Mg4 side X. Those correspond
with the masked channels on the Muvi1
11x
Fixed
com2019
Sat Apr 6 02:52:51 2019
Iulian Ruxandra
RUN
Software
Online Scalers run 256 @2h30 am 06/04 for reference
Fixed
com2019
Sat Apr 6 03:22:30 2019
Iulian Ruxandra
RUN
Software
New Kinematics plots (4h of stats)
More statistics on the script written by Adrian
and Valerian (first image)
Fixed
e744s
Mon Apr 8 00:41:53 2019
Francois
OTHER
General
Predictions for VAMOS plots with 14N and 14O beams
Fixed
Mon Apr 8 07:54:53 2019
iulian
MUST2
Hardware
end alpha contamination run
Problem M3 EY , moving piedestal... See below
Alfa spectra have changed, no longer continuous
excepting partially MM2.
Fixed
Mon Apr 8 08:01:04 2019
iulian
MUST2
Hardware
swiching off HV & BT (in that order)
switching off HV & BT now :
>lpcgrit
>hvm_print MUST2
Fixed
e744s
Mon Apr 8 15:17:28 2019
François
TARGET
General
E744 Targets
Targets mounted on holder
Fixed
e744s
Tue Apr 9 18:08:22 2019
Marlène and François
DAQ
Software
new inputs in the ADC Mugast
new inputs in the ADC mugast
T_Mugast_HF = input N°2
E_AGATA = agata 42 = input N°3
Fixed
Tue Apr 9 21:47:20 2019
Marlene Valerian
GRIT
General
FSC time calibration 9th april evening
Snapshot of FSC calibration just before experiment
The noisy MG detectors are still there but
Fixed
e744s
Wed Apr 10 06:45:53 2019
François
BEAM
Social
No beam yet
They are about to align the beam from the
cyclotron CIME to the area G1.
Fixed
e744s
Wed Apr 10 06:51:35 2019
Beyhan
BEAM
General
14N7+ beam characteristics and settings at VAMOS
Fixed
e744s
Wed Apr 10 07:15:22 2019
François
BEAM
Social
no beam
They aligned the beam up to G1 Pr31 but the
stripper foil was not inserted, so they have
Fixed
e744s
Wed Apr 10 09:05:33 2019
François
BEAM
Social
No beam in G1 yet.
The beam is at the entrance of G1.
Fixed
e744s
Wed Apr 10 10:15:38 2019
François
BEAM
Social
Beam stopped
A problem with the cooling water.
2 UT at least to restart the accelerator
Pinned
e744s
Wed Apr 10 11:57:37 2019
A. Lemasson
OFFLINE
Software
VAMOS Conversion HowTo
[B]HOW TO convert a run in VAMOS[/B]
[LIST]
Fixed
e744s
Thu Apr 11 02:12:42 2019
François
TARGET
General
Measured target thicknesses
[COLOR=blue]CATS2[/COLOR]
Incident beam 14N7+ Brho 0.79 Tm
Fixed
e744s
Thu Apr 11 02:53:20 2019
Marlène
RUN
General
TAc VAMOS-CATS
Just before RUN 68
TAC VAMOS-CATS is now in TAC CATS1-CATS2
in order to check if we see something in
Fixed
e744s
Thu Apr 11 02:54:09 2019
mugast
RUN
General
Changing Brho to 0.51 Tm starting run 70
Fixed
e744s
Thu Apr 11 06:38:12 2019
Diego
VAMOS
Hardware
TACS modification
+300 ns of delay in the HF validated signal
that gives the STOP of T_FPMW_HF && T_CATS2_HF.
Goto page
Previous
1
,
2
,
3
...
121
, 122,
123
...
130
,
131
,
132
Next
ELOG Home Page