Fri Apr 5 19:05:56 2019 |
Marlène Nicolas | GRIT | General | | Brho beam & 17O |
Brho of 16O @ 6 MeV/A after 1mg/cm2 = 0.68906
Brho of 17O for g.s. after 1 mg/cm2=0.71065
Brho of 17O @ 871 keV after 1mg/cm2=0.70831 |
Fixed | com2019 |
Sat Apr 6 02:48:39 2019 |
Iulian Ruxandra | RUN | Software | | Online Spectra run 256 @2h30 am 06/04 (for reference) |
The online spectra (for reference)
No timing on Mg3 & Mg4 side X. Those correspond with the masked channels on the Muvi1 |
Attachment 1: Run_256_Impact_Matrix.png
|
|
Attachment 2: Run_256_Must_X_side.png
|
|
Attachment 3: Run_256_TACs.png
|
|
Attachment 4: Run_256_Must_Y_side.png
|
|
Attachment 5: Run_256_Must_X_side.png
|
|
Attachment 6: Run_256_Impact_Matrix.png
|
|
Attachment 7: Run_256_Vamos_1.png
|
|
Attachment 8: Run_256_Vamos_2.png
|
|
Attachment 9: Run_256_Vamos_3.png
|
|
Attachment 10: Run_256_Vamos_4.png
|
|
Attachment 11: Run_256_Vamos_5.png
|
|
Fixed | com2019 |
Sat Apr 6 02:52:51 2019 |
Iulian Ruxandra | RUN | Software | | Online Scalers run 256 @2h30 am 06/04 for reference |
|
Attachment 1: Run_256_Scaler1.png
|
|
Attachment 2: Run_256_Scaler2.png
|
|
Attachment 3: Run_256_Scaler3.png
|
|
Attachment 4: Run_256_Scaler4.png
|
|
Fixed | com2019 |
Sat Apr 6 03:22:30 2019 |
Iulian Ruxandra | RUN | Software | | New Kinematics plots (4h of stats) |
More statistics on the script written by Adrian and Valerian (first image)
Second image is a comparison between the excited states produced between 90-130 deg and 130-180 deg. Effects of angular distribution?
the kinematic line seen in the Elab vs Theta at backward angles can be observed in figure 3. Are those protons? |
Attachment 1: Kine256_0-256_3.pdf
|
|
Attachment 2: Kine256_0-256_3_comparison.pdf
|
|
Attachment 3: Elab_vs_ThetaLab_backward.pdf
|
|
Fixed | e744s |
Mon Apr 8 00:41:53 2019 |
Francois | OTHER | General | | Predictions for VAMOS plots with 14N and 14O beams |
|
Attachment 1: Kineplots.pdf
|
|
Fixed | |
Mon Apr 8 07:54:53 2019 |
iulian | MUST2 | Hardware | | end alpha contamination run |
Problem M3 EY , moving piedestal... See below
Alfa spectra have changed, no longer continuous excepting partially MM2. |
Attachment 1: bilan_run262_bck_mugast4.png
|
|
Attachment 2: bilan_run262_bck_mugast3.png
|
|
Attachment 3: bilan_run262_bck_mugast2.png
|
|
Attachment 4: bilan_run262_bck_mugast1.png
|
|
Fixed | |
Mon Apr 8 08:01:04 2019 |
iulian | MUST2 | Hardware | | swiching off HV & BT (in that order) |
switching off HV & BT now :
>lpcgrit
>hvm_print MUST2
> hvm_group HV-CsI off
>hvm_group HV-Si off
>hvm_group BTMG-A off
>hvm_group BTMG-B off
>hvm_print MUST2
>hvm_print VAMOS |
Attachment 1: HV_mugast_end1.png
|
|
Attachment 2: HV_mugast_end2.png
|
|
Attachment 3: HV_mugast_end3.png
|
|
Attachment 4: HV_mugast_end4.png
|
|
Fixed | e744s |
Mon Apr 8 15:17:28 2019 |
François | TARGET | General | | E744 Targets |
Targets mounted on holder
N°1 Hole Diam=7 mm
N°2 CH2 104 µm => 9.67 mg/cm2 (polyethylene density = 0.93 g/cm3) Georges@2018
N°3 CH2 100 µm Goodfellow (polyethylene)
N°4 Carbon 75 µm => 6.75 < thick < 9.75 mg/cm2 (Graphite flexible, density 0,9-1,3 g/cm3) Goodfellow
N°5 CH2 73 µm Georges@2019
N°6 CH2 104 µm Georges@2019 |
Attachment 1: 20190408_143035.jpg
|
|
Fixed | e744s |
Tue Apr 9 18:08:22 2019 |
Marlène and François | DAQ | Software | | new inputs in the ADC Mugast |
new inputs in the ADC mugast
T_Mugast_HF = input N°2
E_AGATA = agata 42 = input N°3
T_AGATA_HF = N° 4
gains of the signal AGATA 42 were changed from 200 to 50
|
Fixed | |
Tue Apr 9 21:47:20 2019 |
Marlene Valerian | GRIT | General | | FSC time calibration 9th april evening |
Snapshot of FSC calibration just before experiment
The noisy MG detectors are still there but otherwise most of them are OK |
Attachment 1: FSC_calib_09042019.png
|
|
Fixed | e744s |
Wed Apr 10 06:45:53 2019 |
François | BEAM | Social | | No beam yet |
They are about to align the beam from the cyclotron CIME to the area G1. |
Fixed | e744s |
Wed Apr 10 06:51:35 2019 |
Beyhan | BEAM | General | | 14N7+ beam characteristics and settings at VAMOS |
|
Attachment 1: IMG_1552.jpg
|
|
Attachment 2: IMG_1549.jpg
|
|
Attachment 3: IMG_1550.jpg
|
|
Attachment 4: IMG_1553.jpg
|
|
Fixed | e744s |
Wed Apr 10 07:15:22 2019 |
François | BEAM | Social | | no beam |
They aligned the beam up to G1 Pr31 but the stripper foil was not inserted, so they have to start the work again. |
Fixed | e744s |
Wed Apr 10 09:05:33 2019 |
François | BEAM | Social | | No beam in G1 yet. |
The beam is at the entrance of G1. |
Fixed | e744s |
Wed Apr 10 10:15:38 2019 |
François | BEAM | Social | | Beam stopped |
A problem with the cooling water.
2 UT at least to restart the accelerator |
Pinned | e744s |
Wed Apr 10 11:57:37 2019 |
A. Lemasson | OFFLINE | Software | | VAMOS Conversion HowTo |
HOW TO convert a run in VAMOS
- Do : source $HOME/GoToVamosAna
- To Convert a Run : MyVAna -d2Ar <RunNr>
- Otherwise, If you want to convert a single file : MyVAna -d2Ar -f <Infile> <OutFile>
- Output Root rile is written to : ./RootA/
If you encounter the error on Brho "Could not find the BrhoRef for the run <RunNr> ", Update the ./Calibs/ListBrho.dat file with relevant Brho for RunNr |
Fixed | e744s |
Thu Apr 11 02:12:42 2019 |
François | TARGET | General | | Measured target thicknesses |
CATS2
Incident beam 14N7+ Brho 0.79 Tm
Brho (6+) measured after CATS2 = 0.9148 Tm => energy = 7.38627 MeV/u
Measured = 3.97 µm mylar + 20 mm gas
N°2 CH2 104 µm
= 9.67 mg/cm2 (polyethylene density = 0.93 g/cm3) Georges@2018
Measured :
Brho(6+) = 0.7473 Tm => E=4.9355 MeV/u => e=109.7 µm
Brho(5+) = 0.8924 Tm => E=4.8874 MeV/u => e=111.5 µm
Measured e=110.6 µm
N°3 CH2 100 µm Goodfellow (polyethylene)
Measured Brho(6+)=0.7754 Tm => E=5.3126 MeV/u
Measured e= 95 µm
N°4 Carbon 75 µm
=> 6.75 < thick < 9.75 mg/cm2 (Graphite flexible, density 0,9-1,3 g/cm3) Goodfellow
measured Brho(6+)=0.811 Tm (very broad) => E=5.81006 MeV/u
Measured e=8.4 mg/cm2
N°5 CH2 73 µm Georges@2019
N°6 CH2 104 µm Georges@2019 |
Fixed | e744s |
Thu Apr 11 02:53:20 2019 |
Marlène | RUN | General | | TAc VAMOS-CATS |
Just before RUN 68
TAC VAMOS-CATS is now in TAC CATS1-CATS2 in order to check if we see something in the online spectra.
TCATS total delay = 300 + 500 ns=800 ns
TODO : put back the right ADC channel |
Fixed | e744s |
Thu Apr 11 02:54:09 2019 |
mugast | RUN | General | | Changing Brho to 0.51 Tm starting run 70 |
|
Fixed | e744s |
Thu Apr 11 06:38:12 2019 |
Diego | VAMOS | Hardware | | TACS modification |
+300 ns of delay in the HF validated signal that gives the STOP of T_FPMW_HF && T_CATS2_HF.
Range of TAC FPMW_CATS2 increased to 1us. |