Fixed, , Fri Apr 5 19:05:56 2019, Marlène Nicolas, GRIT, General, , Brho beam & 17O
|
Brho of 16O @ 6 MeV/A after 1mg/cm2 = 0.68906
Brho of 17O for g.s. after 1 mg/cm2=0.71065
Brho of 17O @ 871 keV after 1mg/cm2=0.70831 |
Fixed, com2019, Sat Apr 6 02:48:39 2019, Iulian Ruxandra, RUN, Software, , Online Spectra run 256 @2h30 am 06/04 (for reference) 11x
|
The online spectra (for reference)
No timing on Mg3 & Mg4 side X. Those correspond with the masked channels on the Muvi1 |
Fixed, com2019, Sat Apr 6 02:52:51 2019, Iulian Ruxandra, RUN, Software, , Online Scalers run 256 @2h30 am 06/04 for reference   
|
|
Fixed, com2019, Sat Apr 6 03:22:30 2019, Iulian Ruxandra, RUN, Software, , New Kinematics plots (4h of stats)  
|
More statistics on the script written by Adrian and Valerian (first image)
Second image is a comparison between the excited states produced between 90-130 deg and 130-180 deg. Effects of angular distribution?
the kinematic line seen in the Elab vs Theta at backward angles can be observed in figure 3. Are those protons? |
Fixed, e744s, Mon Apr 8 00:41:53 2019, Francois, OTHER, General, , Predictions for VAMOS plots with 14N and 14O beams
|
|
Fixed, , Mon Apr 8 07:54:53 2019, iulian, MUST2, Hardware, , end alpha contamination run   
|
Problem M3 EY , moving piedestal... See below
Alfa spectra have changed, no longer continuous excepting partially MM2. |
Fixed, , Mon Apr 8 08:01:04 2019, iulian, MUST2, Hardware, , swiching off HV & BT (in that order)   
|
switching off HV & BT now :
>lpcgrit
>hvm_print MUST2
> hvm_group HV-CsI off
>hvm_group HV-Si off
>hvm_group BTMG-A off
>hvm_group BTMG-B off
>hvm_print MUST2
>hvm_print VAMOS |
Fixed, e744s, Mon Apr 8 15:17:28 2019, François, TARGET, General, , E744 Targets
|
Targets mounted on holder
N°1 Hole Diam=7 mm
N°2 CH2 104 µm => 9.67 mg/cm2 (polyethylene density = 0.93 g/cm3) Georges@2018
N°3 CH2 100 µm Goodfellow (polyethylene)
N°4 Carbon 75 µm => 6.75 < thick < 9.75 mg/cm2 (Graphite flexible, density 0,9-1,3 g/cm3) Goodfellow
N°5 CH2 73 µm Georges@2019
N°6 CH2 104 µm Georges@2019 |
Fixed, e744s, Tue Apr 9 18:08:22 2019, Marlène and François, DAQ, Software, , new inputs in the ADC Mugast
|
new inputs in the ADC mugast
T_Mugast_HF = input N°2
E_AGATA = agata 42 = input N°3
T_AGATA_HF = N° 4
gains of the signal AGATA 42 were changed from 200 to 50
|
Fixed, , Tue Apr 9 21:47:20 2019, Marlene Valerian, GRIT, General, , FSC time calibration 9th april evening
|
Snapshot of FSC calibration just before experiment
The noisy MG detectors are still there but otherwise most of them are OK |
Fixed, e744s, Wed Apr 10 06:45:53 2019, François, BEAM, Social, , No beam yet
|
They are about to align the beam from the cyclotron CIME to the area G1. |
Fixed, e744s, Wed Apr 10 06:51:35 2019, Beyhan, BEAM, General, , 14N7+ beam characteristics and settings at VAMOS   
|
|
Fixed, e744s, Wed Apr 10 07:15:22 2019, François, BEAM, Social, , no beam
|
They aligned the beam up to G1 Pr31 but the stripper foil was not inserted, so they have to start the work again. |
Fixed, e744s, Wed Apr 10 09:05:33 2019, François, BEAM, Social, , No beam in G1 yet.
|
The beam is at the entrance of G1. |
Fixed, e744s, Wed Apr 10 10:15:38 2019, François, BEAM, Social, , Beam stopped
|
A problem with the cooling water.
2 UT at least to restart the accelerator |
Pinned, e744s, Wed Apr 10 11:57:37 2019, A. Lemasson, OFFLINE, Software, , VAMOS Conversion HowTo
|
HOW TO convert a run in VAMOS
- Do : source $HOME/GoToVamosAna
- To Convert a Run : MyVAna -d2Ar <RunNr>
- Otherwise, If you want to convert a single file : MyVAna -d2Ar -f <Infile> <OutFile>
- Output Root rile is written to : ./RootA/
If you encounter the error on Brho "Could not find the BrhoRef for the run <RunNr> ", Update the ./Calibs/ListBrho.dat file with relevant Brho for RunNr |
Fixed, e744s, Thu Apr 11 02:12:42 2019, François, TARGET, General, , Measured target thicknesses
|
CATS2
Incident beam 14N7+ Brho 0.79 Tm
Brho (6+) measured after CATS2 = 0.9148 Tm => energy = 7.38627 MeV/u
Measured = 3.97 µm mylar + 20 mm gas
N°2 CH2 104 µm
= 9.67 mg/cm2 (polyethylene density = 0.93 g/cm3) Georges@2018
Measured :
Brho(6+) = 0.7473 Tm => E=4.9355 MeV/u => e=109.7 µm
Brho(5+) = 0.8924 Tm => E=4.8874 MeV/u => e=111.5 µm
Measured e=110.6 µm
N°3 CH2 100 µm Goodfellow (polyethylene)
Measured Brho(6+)=0.7754 Tm => E=5.3126 MeV/u
Measured e= 95 µm
N°4 Carbon 75 µm
=> 6.75 < thick < 9.75 mg/cm2 (Graphite flexible, density 0,9-1,3 g/cm3) Goodfellow
measured Brho(6+)=0.811 Tm (very broad) => E=5.81006 MeV/u
Measured e=8.4 mg/cm2
N°5 CH2 73 µm Georges@2019
N°6 CH2 104 µm Georges@2019 |
Fixed, e744s, Thu Apr 11 02:53:20 2019, Marlène, RUN, General, , TAc VAMOS-CATS
|
Just before RUN 68
TAC VAMOS-CATS is now in TAC CATS1-CATS2 in order to check if we see something in the online spectra.
TCATS total delay = 300 + 500 ns=800 ns
TODO : put back the right ADC channel |
Fixed, e744s, Thu Apr 11 02:54:09 2019, mugast, RUN, General, , Changing Brho to 0.51 Tm starting run 70
|
|
Fixed, e744s, Thu Apr 11 06:38:12 2019, Diego, VAMOS, Hardware, , TACS modification
|
+300 ns of delay in the HF validated signal that gives the STOP of T_FPMW_HF && T_CATS2_HF.
Range of TAC FPMW_CATS2 increased to 1us. |
|