MUST2 SAMURAI_2018 S3-LEB-LPC SUPERNEMO MUGAST EXPAND SCALP GALATRON HiCARI VELO
  MUGAST, Page 122 of 127  Not logged in MUGAST
Fixed, e793s, Sat Mar 13 05:33:41 2021, Faïrouz, Juan Lois, RUN, General, CD2, run61 screenshots at 5h30 8x
 
Fixed, e793s, Sat Mar 13 07:18:10 2021, OttoRun, RUN, General, CD2, Run62 
*************************
  [SIZE=3][B]Run  : 62[/B][/SIZE]
*************************
Fixed, e793s, Sat Mar 13 07:26:40 2021, Faïrouz, Juan Lois, RUN, General, CD2, End of run61 screenshots at 7h20 7x
RUN 61 stopped to let Emmanuel fix the AGATA acquisition problem. 
Fixed, e793s, Sat Mar 13 07:29:56 2021, Faïrouz, Juan Lois, AGATA, Software, CD2, AGATA acquisition problem fixed by Emmanuel 
 
Fixed, e793s, Sat Mar 13 07:31:13 2021, Faïrouz, Juan Lois, RUN, General, CD2, Run 62 scalers run62_scaler_7h20.png
 
Fixed, e793s, Sat Mar 13 09:19:14 2021, Lynda, Laetitia, Chloe, ONLINE, General, CD2, run62 screenshots at 9h10 10x
Online spectra reset at 9h20
Fixed, e793s, Sat Mar 13 10:11:44 2021, Adrien, OFFLINE, General, CD2, Offline analysis of run 51-61 Plot51-61.pngAngle51-61.png
Run 51 to 61 are converted and analysed. 
I fixed the gamma/no gamma normalisation after binning change.
Fixed, e793s, Sat Mar 13 10:14:16 2021, Lynda, Laetitia, Chloe, VAMOS, General, , Vamos tripped @ 10:10 & fixed run62_scaler_9h16.png
Vamos tripped around 10:10. we switched back 3 HV on
Online spectra reset to check
Fixed, e793s, Sat Mar 13 11:16:38 2021, Lynda, Laetitia, Chloe, BEAM, General, , beam lost and back 
we loose the beam around 11:12, it should be back in few minutes according to pcp.

11:18: the beam is back (3.5E5 pps)
Fixed, e793s, Sat Mar 13 11:52:26 2021, Lynda, Laetitia, Chloe, BEAM, General, CD2, Beam lost 
A security problem occurs at a door near CSS1 ( AFR alarm ), need to call the security to fix the problem
The person needs to come so it will take ~1h
Fixed, e793s, Sat Mar 13 12:07:32 2021, Lynda, Laetitia, Chloe, ONLINE, General, CD2, run 62 screenshots at 11h55 10x
 
Fixed, e793s, Sat Mar 13 13:16:04 2021, Franco, OFFLINE, General, CD2, Angular distributions ang_distr_run51-61.pnggamma_gateEx.png
- Updated the macro for the angular distributions.
- For the angular distribution of the peak at 4 MeV excitation energy I think we need the calculation for the transfer 0f5/2.
- Added the gamma spectra gated on the 3 main peaks in Ex in the macro DrawPlots.C (arrows and labels of the gamma should be added).
Fixed, e793s, Sat Mar 13 13:46:42 2021, Chloe F., OFFLINE, General, CD2, analysis gg gg_e793s_gat.pnggg_e793s_gat_2.png
> > Up to now data (run 46-51-52-53-55-56-60-61-62)
Decays seen from level scheme:
3- (451,280)keV
Fixed, e793s, Sat Mar 13 14:41:28 2021, Lynda, Laetitia, Chloe, BEAM, General, CD2, Beam is back run62_scaler_graph_14h48.png
Beam is back ~ 14h35, safety problem fixed
PCP said that the source is unstable so the beam intensity will fluctuate
Fixed, e793s, Sat Mar 13 14:49:40 2021, Charlie, OFFLINE, General, CD2, TWOFNR for 4 MeV, 0f5/2 24.f52_4MeV_sp324.f52_4MeV_sp2TWOFNR_graph_w_comparison.png
In response to Franco's comment [URL=https://caeelog.in2p3.fr/MUGAST/6119]here[/URL], I ran some quick TWOFNR simulations for a 0f5/2 transfer on to 4 MeV,
on to spin 2 or 3. The attached files are named as follows:
Fixed, e793s, Sat Mar 13 17:35:57 2021, Sarah Louis Wilton, RUN, General, CD2, run62 screenshots at 17h25 9x
 
Fixed, e793s, Sat Mar 13 17:41:57 2021, Sarah Louis Wilton, RUN, General, CD2, Beam intensity increased Beam_at_17h40.pngScalars_at_17h35.png
Bertrand saw that the slits were slightly closed, called the PCP and now we have around 5e5 pps
we can see the increase on the figure at 17h20 
Fixed, e793s, Sat Mar 13 19:54:47 2021, Louis, Sarah, OFFLINE, General, CD2, Preliminary spectroscopic factors  C2S.pnggg_gEx.pngAnaPlot.png
1) Preliminary spectroscopic factors has been extracted for the first 2- exited state @ 143 keV and for the 0- excited state @ 1985 keV. DWBA calul has
been performed by cyril for a p3/2 transfer at 0MeV and a p1/2 transfer at 2MeV. Experimental differential cross section has been extracted by normalising
the number of counts with the total number of incoming 47K (from CATS div), the number of deuteron in the target, and correcting from MUGAST geometrical
Fixed, e793s, Sat Mar 13 20:05:04 2021, Sarah Louis, ONLINE, General, CD2, run62 screenshots at 20h00 10x
 
Fixed, e793s, Sat Mar 13 22:16:59 2021, Sarah Louis Wilton, ONLINE, General, CD2, run62 screenshots at 22h10 10x
 

ELOG Home Page