Fixed, e793s, Wed Mar 17 12:16:20 2021, OttoTime, RUN, General, N/A, TimeCalibratorRun 
*** Run Time Calibrator FSC ***
  - Run: 640
  - MUVI: MUVI3
Fixed, e793s, Wed Mar 17 12:28:40 2021, OttoTime, RUN, General, N/A, TimeCalibratorRun 
*** Run Time Calibrator FSC ***
  - Run: 641
  - MUVI: MUVI4
Fixed, e793s, Wed Mar 17 12:37:09 2021, OttoTime, RUN, General, N/A, TimeCalibratorRun 
*** Run Time Calibrator FSC ***
  - Run: 642
  - MUVI: MUVI4
Fixed, e793s, Wed Mar 17 13:53:04 2021, OttoTime, RUN, General, N/A, TimeCalibratorRun 
*** Run Time Calibrator FSC ***
  - Run: 643
  - MUVI: MUVI1
Fixed, e793s, Wed Mar 17 13:58:29 2021, OttoTime, RUN, General, N/A, TimeCalibratorRun 
*** Run Time Calibrator FSC ***
  - Run: 644
  - MUVI: MUVI1
Fixed, e793s, Wed Mar 17 14:10:30 2021, OttoTime, RUN, General, N/A, TimeCalibratorRun 
*** Run Time Calibrator FSC ***
  - Run: 645
  - MUVI: MUVI1
Fixed, e793s, Wed Mar 17 14:22:31 2021, OttoTime, RUN, General, N/A, TimeCalibratorRun 
*** Run Time Calibrator FSC ***
  - Run: 646
  - MUVI: MUVI2
Fixed, e793s, Wed Mar 17 14:34:43 2021, OttoTime, RUN, General, N/A, TimeCalibratorRun 
*** Run Time Calibrator FSC ***
  - Run: 647
  - MUVI: MUVI2
Fixed, e793s, Wed Mar 17 14:46:59 2021, OttoTime, RUN, General, N/A, TimeCalibratorRun 
*** Run Time Calibrator FSC ***
  - Run: 648
  - MUVI: MUVI3
Fixed, e793s, Wed Mar 17 14:59:17 2021, OttoTime, RUN, General, N/A, TimeCalibratorRun 
*** Run Time Calibrator FSC ***
  - Run: 649
  - MUVI: MUVI3
Fixed, e793s, Wed Mar 17 15:11:37 2021, OttoTime, RUN, General, N/A, TimeCalibratorRun 
*** Run Time Calibrator FSC ***
  - Run: 650
  - MUVI: MUVI4
Ongoing, e793s, Wed Mar 17 15:17:39 2021, Emmanuel C, OFFLINE, General, , New gamma gamma analysis 48K.pdf
The level scheme is based on coherent check of
1- gamma gamma
2- gamma gated by Ex
Fixed, e793s, Wed Mar 17 15:20:08 2021, OttoTime, RUN, General, N/A, TimeCalibratorRun 
*** Run Time Calibrator FSC ***
  - Run: 651
  - MUVI: MUVI4
Fixed, e793s, Wed Mar 17 19:19:05 2021, Franco, OFFLINE, General, CD2, Mugast detectors disaligned in Ex detectors_disalignment_Ex.pngEx_aligned_vs_unaligned.png
The Ex distributions gated on the different MG detectors show large differences, up to 500 keV. In the attached figure I show as an example the comparison
between two nearby detectors, MG3 and MG4.
I tried a rough alignment of the Ex by shifting it manually and setting the first main peak at Ex=0 (essentially taking MG5 as the reference, since his
Fixed, e793s, Fri Mar 19 09:54:58 2021, Adrien, Freddy and Franco, GRIT, General, 3-alpha, Alpha calibration and noise on MG3 and MG4 after the experiment 
While starting the alpha source runs after the experiment we found unexpected noise on MG3 and MG4 which cannot be excluded just by masking some Y mates
(The X mates were already masked for both of them). We cannot figure out the origin of this noise.
Fixed, e793s, Mon Mar 22 16:35:46 2021, OttoRun, RUN, General, N/A, Run67 
*************************
  [SIZE=3][B]Run  : 67[/B][/SIZE]
*************************
Fixed, e793s, Mon Mar 22 18:15:50 2021, mugast, RUN, General, N/A, TACS calibration - run 662 
TACS:

    FAG-CATS2 (range 500 ns)
Fixed, e793s, Mon Mar 22 19:04:55 2021, mugast, RUN, General, N/A, TACS calibration - run 653 
TACS:

MUGAST-AGATA (range 2 us)
Fixed, e793s, Sat Mar 13 18:37:01 2021, Emmanuel C, OFFLINE, General, , Efficiency gamma AGATA 
 TF1 *fit_1 = new TF1("fit_1","TMath::Exp([0]+[1]*TMath::Log(x)+[2]*pow(TMath::Log(x),2.0)+[3]*pow(TMath::Log(x),3.0)+[4]*pow(TMath::Log(x),4.0))",100,5000);
 //NRJ traite en keV et efficiency en %
     p0          -7.84071e+00   
    Fixed, e793s, Thu Mar 18 16:25:56 2021, Emmanuel C, OFFLINE, General, , Efficiency gamma AGATA --- real measurement run70 
[quote="Emmanuel C"] TF1 *fit_1 = new TF1("fit_1","TMath::Exp([0]+[1]*TMath::Log(x)+[2]*pow(TMath::Log(x),2.0)+[3]*pow(TMath::Log(x),3.0)+[4]*pow(TMath::Log(x),4.0))",10,5000);
 //NRJ traite en keV et efficiency en %
       Fixed, e793s, Tue Mar 23 10:22:48 2021, Emmanuel C, OFFLINE, General, , Efficiency gamma AGATA --- real measurement run70 effi.png

I have been working on the high energy response.
The point is that we do not have source measurement beyond 2 MeV to constrain the fit. 