MUGAST, Page 119 of 132
Not logged in
Find
|
Login
Full
| Summary |
Threaded
2636 Entries
Goto page
Previous
1
,
2
,
3
...
118
, 119,
120
...
130
,
131
,
132
Next
Status
ExpNbr
Date
Author
Type
Category
Target-Source
Subject
Text
Fixed
TEST
Tue Mar 10 11:05:40 2020
Franco
GRIT
Hardware
3-alpha
Trip in the cooling system after e775s experiment
In the weekend after the experiment e775s
(7-8 March 2020) a problem with the cooling
system of Mugast occurred. In particular,
Fixed
e793s
Tue Mar 10 18:46:13 2020
Franco & Marlène
GRIT
Hardware
Changes in MUGAST
- MG6 (FZ) is disconnected.
- MG7 (500um) is dismounted and MG8 (375um)
is replacing it.
Fixed
TEST
Wed Mar 11 18:12:40 2020
Marlène & Franco
GRIT
Hardware
N/A
Update on Mugast
(Probably) final update of the status of the
detector before the experiment:
Fixed
e793s
Wed Mar 11 19:02:54 2020
mugast
GRIT
General
3-alpha
Alpha calibration for e793s - run 600
========================================
========================================
========================================
Fixed
e793s
Wed Mar 11 22:01:18 2020
mugast
GRIT
General
3-alpha
Alpha calibration - run 600
After 2h30' of run we checked the temperatures
of the boards and we noticed that MG7 had
63 degrees on both X and Y, which is very
Fixed
TEST
Thu Mar 12 10:14:02 2020
Marlène & Franco
GRIT
Hardware
N/A
Debugging the cooling system
We realized that the increase of temperature
of MG7 and MG9 during run 600 (alpha calibration)
was due to the fact that a loop of the cooling
Fixed
TEST
Thu Mar 12 14:47:59 2020
Marlène & Franco
GRIT
Hardware
N/A
Moving MG9 square to MUVI2
- Since we are not using MG6 anymore (card
burnt), we replaced it with MG9 on slot 3
of MUVI2. MUVI4 is now unused. We changed
Fixed
e793s
Thu Mar 12 14:54:13 2020
Marlène & Franco
GRIT
General
3-alpha
Run 0601 - alpha source calibration
We start the alpha source calibration run
with pedestal suppression (except for MG7
and MG9) and cooling at 0 deg.
Fixed
e793s
Thu Mar 12 15:48:58 2020
Franco&Marlène
GRIT
General
Summary and TO DO list 12/03/2020
What remains to be done
- Do the time calibration of all boards (time
calibrator has to be connected)
Fixed
e793s
Thu Mar 12 17:25:19 2020
mugast
GRIT
General
3-alpha
run 0601 - alpha source with pedestals
Alpha source calibration run without pedestal
suppression and cooling at 0 deg.
Fixed
e793s
Fri Jan 29 15:11:54 2021
Adrien
VACUUM
General
N/A
MUGAST undervacuum and powered up
MUGAST is undervacuum thanks to Arnaud and
Laurent.
Fixed
TEST
Tue Feb 2 16:41:17 2021
Franco
VACUUM
Hardware
N/A
MUGAST undervacuum and powered up
I put back the supply of MM1 to the channel
1 of the MUST2 box (as in the normal configuration)
and polarized the detectors to make a rapid
Fixed
TEST
Wed Feb 3 16:42:41 2021
Franco
GRIT
General
3-alpha
Status of the set-up (February 3rd 2021)
We re-mounted the annular, put the source
and cooled down to 0 deg. Voltages and spectra
are attached.
Fixed
TEST
Thu Feb 4 18:16:47 2021
Franco
GRIT
Hardware
3-alpha
Problems with the annular persist
We opened the chamber to verify the connections
of the kaptons but they were all well connected.
We checked with the tester the conductivity
8x
Fixed
TEST
Fri Feb 5 12:44:42 2021
Franco
GRIT
Hardware
N/A
Pulser on MG11 MUFEE Y
I managed to obtain the spectrum with the
pulser on the annular (Y side, namely sectors).
The raw strip numbers where I should have
Fixed
e793s
Mon Feb 8 10:27:23 2021
OttoTime
RUN
General
N/A
TimeCalibratorRun
*** Run Time Calibrator FSC ***
- Run: 605
- MUVI: MUVI1
Fixed
e793s
Mon Feb 8 10:39:35 2021
OttoTime
RUN
General
N/A
TimeCalibratorRun
*** Run Time Calibrator FSC ***
- Run: 606
- MUVI: MUVI1
Fixed
e793s
Mon Feb 8 10:51:48 2021
OttoTime
RUN
General
N/A
TimeCalibratorRun
*** Run Time Calibrator FSC ***
- Run: 607
- MUVI: MUVI2
Fixed
e793s
Mon Feb 8 11:04:04 2021
OttoTime
RUN
General
N/A
TimeCalibratorRun
*** Run Time Calibrator FSC ***
- Run: 608
- MUVI: MUVI2
Fixed
e793s
Mon Feb 8 11:16:18 2021
OttoTime
RUN
General
N/A
TimeCalibratorRun
*** Run Time Calibrator FSC ***
- Run: 609
- MUVI: MUVI3