MUST2
SAMURAI_2018
S3-LEB-LPC
SUPERNEMO
MUGAST
EXPAND
SCALP
GALATRON
HiCARI
VELO
MUGAST, Page 119 of 132
Not logged in
Find
|
Login
New entries since:
Thu Jan 1 01:00:00 1970
Full
| Summary |
Threaded
2636 Entries
Goto page
Previous
1
,
2
,
3
...
118
, 119,
120
...
130
,
131
,
132
Next
Status
ExpNbr
Date
Author
Type
Category
Target-Source
Subject
Text
Fixed
TEST
Tue Feb 2 16:41:17 2021
Franco
VACUUM
Hardware
N/A
MUGAST undervacuum and powered up
I put back the supply of MM1 to the channel
1 of the MUST2 box (as in the normal configuration)
and polarized the detectors to make a rapid
Fixed
TEST
Wed Feb 3 16:42:41 2021
Franco
GRIT
General
3-alpha
Status of the set-up (February 3rd 2021)
We re-mounted the annular, put the source
and cooled down to 0 deg. Voltages and spectra
are attached.
Fixed
TEST
Thu Feb 4 18:16:47 2021
Franco
GRIT
Hardware
3-alpha
Problems with the annular persist
We opened the chamber to verify the connections
of the kaptons but they were all well connected.
We checked with the tester the conductivity
8x
Fixed
TEST
Fri Feb 5 12:44:42 2021
Franco
GRIT
Hardware
N/A
Pulser on MG11 MUFEE Y
I managed to obtain the spectrum with the
pulser on the annular (Y side, namely sectors).
The raw strip numbers where I should have
Fixed
e793s
Mon Feb 8 10:27:23 2021
OttoTime
RUN
General
N/A
TimeCalibratorRun
*** Run Time Calibrator FSC ***
- Run: 605
- MUVI: MUVI1
Fixed
e793s
Mon Feb 8 10:39:35 2021
OttoTime
RUN
General
N/A
TimeCalibratorRun
*** Run Time Calibrator FSC ***
- Run: 606
- MUVI: MUVI1
Fixed
e793s
Mon Feb 8 10:51:48 2021
OttoTime
RUN
General
N/A
TimeCalibratorRun
*** Run Time Calibrator FSC ***
- Run: 607
- MUVI: MUVI2
Fixed
e793s
Mon Feb 8 11:04:04 2021
OttoTime
RUN
General
N/A
TimeCalibratorRun
*** Run Time Calibrator FSC ***
- Run: 608
- MUVI: MUVI2
Fixed
e793s
Mon Feb 8 11:16:18 2021
OttoTime
RUN
General
N/A
TimeCalibratorRun
*** Run Time Calibrator FSC ***
- Run: 609
- MUVI: MUVI3
Fixed
e793s
Mon Feb 8 11:25:29 2021
Adrien and Freddy
S1
General
N/A
FSC run
we ran FSC on all card. S1 is dismounted.
Pulser goes on all channel and works well
so electronic is fine.
Fixed
e793s
Mon Feb 8 11:28:38 2021
OttoTime
RUN
General
N/A
TimeCalibratorRun
*** Run Time Calibrator FSC ***
- Run: 610
- MUVI: MUVI3
Fixed
e793s
Mon Feb 8 16:20:42 2021
OttoTime
RUN
General
N/A
TimeCalibratorRun
*** Run Time Calibrator FSC ***
- Run: 611
- MUVI: MUVI2
Fixed
e793s
Mon Feb 8 16:33:22 2021
OttoTime
RUN
General
N/A
TimeCalibratorRun
*** Run Time Calibrator FSC ***
- Run: 612
- MUVI: MUVI2
Fixed
e793s
Fri Feb 12 08:52:30 2021
mugast
RUN
General
3-alpha
run 613: long alpha run
all Muvi in trigger, mugast stand alone. all
detector Bias on.
Fixed
e793s
Fri Feb 12 18:07:24 2021
OttoTime
RUN
General
N/A
TimeCalibratorRun
*** Run Time Calibrator FSC ***
- Run: 614
- MUVI: MUVI2
Fixed
e793s
Fri Feb 12 18:12:00 2021
Adrien
S1
Hardware
N/A
Kapton change
Arnaud open today and change the Y Kapton
(YA5) of the S1. Everything under vacuum/cooled
again so I ran FSC, hopefully this will fix
Fixed
e793s
Fri Feb 12 18:19:52 2021
OttoTime
RUN
General
N/A
TimeCalibratorRun
*** Run Time Calibrator FSC ***
- Run: 615
- MUVI: MUVI2
Ongoing
e793s
Wed Mar 3 17:12:57 2021
Franco
S1
Hardware
N/A
Schema of the new S1
The signals of the new S1 will be splitted
among 6 Mugast boards, according to the scheme
attached.
Fixed
e793s
Wed Mar 3 17:18:42 2021
Franco
GRIT
General
N/A
MUVI's scheme and connections on the chamber
Fixed
e775s
Thu Mar 4 10:45:42 2021
OttoRun
RUN
General
N/A
Run200
*************************
[SIZE=3][B]Run : 200[/B][/SIZE]
*************************
Goto page
Previous
1
,
2
,
3
...
118
, 119,
120
...
130
,
131
,
132
Next