FixedTEST Thu Feb 7 09:52:08 2019 Freddy, MarlèneRUNGeneral3-alphaRUN10 : 3 alpha source on MG1-3-4-5-7Test run with alpha source in front of trapezoid
detectors.
 alpha_source_5trap_rawhistos_2.pngalpha_source_5trap_rawhistos.png 
Fixed  Thu Feb 14 08:50:58 2019 MarleneGRITGeneral3-alphaRUN 27RUN 27 on 14th of feb.
3 alpha source (one in front of trap., one
in front of square detectors)
 8x 
Fixed  Thu Feb 14 15:30:14 2019 Marlene Daniele JennyGRITGeneral3-alphaRUN 28RUN 28 14th Feb
3 alpha source on MG11A, MG3T, MG1T
 3alpha_sourceMG03XY._OKpng3alpha_sourceMG11XY.png3alpha_sourceMG01XY_OK.png 
FixedTEST Thu Feb 21 09:08:49 2019 FreddyRUNGeneral3-alphaRUN 30 - alpha on MG 1,3,5,7 [U][B]Run 30[/B][/U]

Alpha source run for trapezoid detectors
 3alpha_source_MG_1357_20Feb.pngLowV_bis_run30.pngLowV_run30.pngHV_run30.png 
FixedTEST Thu Feb 21 14:37:26 2019 iulian, valerian &FreddyGRITHardware3-alphaResults Calibration 3-alpha RUN30 MG1, MG3,MG5 & MG7Results of the calibration run 30
In order:
 Telescope1 X,Y (MG5 X,Y)
 8x 
FixedTEST Thu Feb 21 17:32:42 2019 iulian, freddyGRITHardware3-alpharun 33 3 alfa with MG1,MG3,MG4,MG5,MG7,MG9 short runFirst test of the repaired 2xcables. The repaired
cables were placed between MUVI1_2 <=> MG4
& MUVI1_4 <=>MG11 (longer cable)
 3alpha_sourceMG1MG4MG7MG9XY_run33.png3alpha_sourceMG3MG5XY_run33.png 
FixedTEST Thu Feb 21 18:14:48 2019 iulianGRITHardware3-alphaACQ problem run 34 3 alfa with MG1,MG3,MG4,MG5,MG7,MG9
Alpha source run for trapezoid detectors
+ anulaire detector with pedestals aligned
 acq_problem_21and22fevrier.png 
FixedTEST Fri Feb 22 11:56:53 2019 iulian GRITHardware3-alpharun 38 3-alpha with reordering of the MUGAST cables for the logic and analogic signals[U][B]Run 38
[/B][/U] 
 Alpha source run for trapezoid detectors
 run38_3alpha_mg1345.pngrun38_3alpha_mg711.png 
FixedTEST Fri Feb 22 14:36:35 2019 iulianMUST2Hardware3-alphatest new cable for Must2 detectors. Cables OK!Cables put on Muvi3.
Testing procedure. Use the numbered cables
to conect the annular detector (MG11) and
  
FixedTEST Fri Feb 22 15:54:30 2019 iulian GRITHardware3-alpharun 40 3-alpha night run [CENTER][/CENTER][U][B]Run 40
[/B][/U] 
 Alpha source run for trapezoid detectors
 run40_3alpha_mg1345.pngrun40_3alpha_mg79.png 
FixedTEST Fri Mar 1 12:07:44 2019 FreddyGRITGeneral3-alphaEfficiency reconstructionblue: reconstructed efficiency using alpha
run 40 (arbitratily normalized)
red: simulated efficiency
 comparison.pdfcomparison.Calpha_eff.root 
FixedTEST Mon Mar 4 12:28:26 2019 Valerian and IulianMUST2General3-alphaNo DECS and acq error run 47-48-49. Das Saved after problem fixedFixed. Solution:
1) CENTRUM not configured on GENTRUM Master
2) GMT matrix on GMT3 (2nd slave) was all
 run49_error_acq.png 
FixedTEST Mon Mar 4 13:54:24 2019 iulian & ValerianGRITHardware3-alpharun 50 3-alpha short run[U][B]RUN 50[/B][/U]
First 3a test with  all Must2 detectors.
HV on all set to 50 V for this test only
 run50_3a_Must.pngrun50_3a_Must2.png 
FixedTEST Mon Mar 4 15:30:31 2019 iulian Marlene & ValerianMUST2Hardware3-alpharun 51 3-alpha run with Pedestals Aligned @ 13 deg Measured on cooling system [U][B]RUN 51[/B][/U]
3a run with Pedestals Aligned[I][U] but not[/U][/I]
suppressed 
 run51_HVs.pngrun51_3a_Must3_pedestalAligned.png 
FixedTEST Tue Mar 5 18:18:46 2019 iulian MarleneMUST2Hardware3-alpharun 97 3a run Muvi3 night run Run 87

stop@ 5:42 am
 run87_3alpha_4mm_spectra.png 
FixedTEST Wed Mar 6 15:02:51 2019 ValerianMUST2Hardware3-alphaCooling temperature is relevant for the resolutionUsing run 52 -> 13deg and run 87 -> -5deg.

We see that the resolution improves at -5
 MM2X_13deg.pngMM2X_minus5deg.png 
FixedTEST Mon Mar 18 18:31:18 2019 valerian marlèneGRITGeneral3-alphaRUN 20 (com2019) 3 alpha overnightRUN20

Run with double 3alpha source MUST2+MG1_7+MG11
 RUN20_HV_MG_3lapha.pngRUN20_3alpha_HV_MUST2.png 
FixedTEST Wed Mar 27 11:06:33 2019 Valerian and CyrilGRITHardware3-alphaEvolution of resolution with temperatureFor the mugast telescope, changing the temperature
from 13deg to minus 4deg doesn't seem to
have an impact as strong as for the MUST2
 MG4_13_deg.pngMG4_minus_4_deg.png 
Fixed  Thu Mar 28 18:29:04 2019 marlene valerianGRITGeneral3-alphaRUN 147 3alpha source overnight all detectors -4deg[SIZE=3]RUN 147  start@ 18:30

3 alpha source over night
  
Fixedcom2019 Fri Mar 29 17:11:04 2019 OttoRunRUNGeneral3-alphaRun155*************************
  [SIZE=3][B]Run  : 155[/B][/SIZE]
*************************
  