  MUGAST, Page 114 of 132  Not logged in MUGAST
Status ExpNbr Date Author Type Categorydown Target-Source Subject
Fixede768s Sat Aug 3 05:00:32 2019 OttoTimeRUNGeneralN/ATimeCalibratorRun
*** Run Time Calibrator FSC ***
- Run: 161
- MUVI: MUVI3
- Side : MUFEE X (Junction)
- Telescope: 2,
Fixede768s Sat Aug 3 06:03:51 2019 OttoTimeRUNGeneralN/ATimeCalibratorRun
*** Run Time Calibrator FSC ***
- Run: 161
- MUVI: MUVI3
- Side : MUFEE Y (Ohmic)
- Telescope: 2,
Fixede768s Sat Aug 3 08:13:33 2019 OttoTimeRUNGeneralN/ATimeCalibratorRun
*** Run Time Calibrator FSC ***
- Run: 161
- MUVI: MUVI3
- Side : MUFEE Y (Ohmic)
- Telescope: 3,
Fixede768s Sat Aug 3 09:17:12 2019 OttoTimeRUNGeneralN/ATimeCalibratorRun
*** Run Time Calibrator FSC ***
- Run: 161
- MUVI: MUVI3
- Side : MUFEE X (Junction)
- Telescope: 4
Fixede768s Sat Aug 3 10:21:04 2019 OttoTimeRUNGeneralN/ATimeCalibratorRun
*** Run Time Calibrator FSC ***
- Run: 161
- MUVI: MUVI3
- Side : MUFEE Y (Ohmic)
- Telescope: 4
FixedTEST Wed Feb 12 09:32:17 2020 mugastRUNGeneral3-alphaRun 500 - 3alpha - mugast standalone
RUN 500

start: 11/02/2020 @ 19h00
stop: 12/02/2020 @ 10h00

alpha source test - cooling 14°C

Remarks:
- The two new detectors (MG2 and 6) seem functional;
- MG11 annular, ok for sectors (Y) but many rings have double peaks;
- MM1 current was oscillating yesterday evening with values around 3 uA, this morning it was stable at ~0.55 uA.
Attachment 1: MG_all_X_alpha_source_run500
Attachment 2: MG_all_Y_alpha_source_run500
FixedTEST Fri Feb 14 10:49:22 2020 Marlène & FrancoRUNGeneral3-alphaMG11 issues
We analyzed the behaviour of the annular. We realized that the 4-peaks behaviour on X was already present last year but only on one sector, now it's on two sectors. We noticed that there is a correlation between the malfunctioning sectors and the missing strips on Y. Last year there was only a missing strip on Y, affecting only one sector on X; now 3 strips are missing on Y, affecting 2 sectors on X. We believe that the fact that the boundings are missing have an impact on the grounding, therefore the sectors are not always biased properly, resulting in an oscillation of the pedestal. We estimate that this will cause a loss of efficiency of ~25% for the annular (from ~90% to ~67%).



mugast wrote:
RUN 500

start: 11/02/2020 @ 19h00
stop: 12/02/2020 @ 10h00

alpha source test - cooling 14°C

Remarks:
- The two new detectors (MG2 and 6) seem functional;
- MG11 annular, ok for sectors (Y) but many rings have double peaks;
- MM1 current was oscillating yesterday evening with values around 3 uA, this morning it was stable at ~0.55 uA.
Fixede768s Fri Feb 14 11:11:57 2020 OttoTimeRUNGeneralN/ATimeCalibratorRun
*** Run Time Calibrator FSC ***
- Run: 502
- MUVI: MUVI1
- Side : MUFEE X (Junction)
- Telescope: 1, 2, 3, 4
Fixede768s Fri Feb 14 11:23:56 2020 OttoTimeRUNGeneralN/ATimeCalibratorRun
*** Run Time Calibrator FSC ***
- Run: 503
- MUVI: MUVI1
- Side : MUFEE Y (Ohmic)
- Telescope: 1, 2, 3, 4
Fixede768s Fri Feb 14 11:35:44 2020 OttoTimeRUNGeneralN/ATimeCalibratorRun
*** Run Time Calibrator FSC ***
- Run: 504
- MUVI: MUVI2
- Side : MUFEE X (Junction)
- Telescope: 1, 2, 3, 4
Attachment 1: TimeCal_MGX.png
TimeCal_MGX.png
Fixede768s Fri Feb 14 11:47:31 2020 OttoTimeRUNGeneralN/ATimeCalibratorRun
*** Run Time Calibrator FSC ***
- Run: 505
- MUVI: MUVI2
- Side : MUFEE Y (Ohmic)
- Telescope: 1, 2, 3, 4
Attachment 1: TimeCal_MGY.png
TimeCal_MGY.png
Fixede768s Fri Feb 14 11:59:24 2020 OttoTimeRUNGeneralN/ATimeCalibratorRun
*** Run Time Calibrator FSC ***
- Run: 506
- MUVI: MUVI3
- Side : MUFEE X (Junction)
- Telescope: 1, 2, 3, 4
Fixede768s Fri Feb 14 12:11:23 2020 OttoTimeRUNGeneralN/ATimeCalibratorRun
*** Run Time Calibrator FSC ***
- Run: 507
- MUVI: MUVI3
- Side : MUFEE Y (Ohmic)
- Telescope: 1, 2, 3, 4
Attachment 1: TimeCal_M2.png
TimeCal_M2.png
Fixede768s Fri Feb 14 12:23:24 2020 OttoTimeRUNGeneralN/ATimeCalibratorRun
*** Run Time Calibrator FSC ***
- Run: 508
- MUVI: MUVI4
- Side : MUFEE X (Junction)
- Telescope: 1, 2, 3, 4
Fixede768s Fri Feb 14 12:35:18 2020 OttoTimeRUNGeneralN/ATimeCalibratorRun
*** Run Time Calibrator FSC ***
- Run: 509
- MUVI: MUVI4
- Side : MUFEE Y (Ohmic)
- Telescope: 1, 2, 3, 4
Fixede768s Fri Feb 14 17:17:18 2020 OttoTimeRUNGeneralN/ATimeCalibratorRun
*** Run Time Calibrator FSC ***
- Run: 510
- MUVI: MUVI2
- Side : MUFEE X (Junction)
- Telescope: 1, 2, 3, 4
Attachment 1: TimeCal_MGX_r510.png
TimeCal_MGX_r510.png
FixedTEST Fri Feb 14 17:26:05 2020 mugastOTHERGeneralN/ARun 517 - Pedestal with source
RUN 517

Pedestal run with alpha source
Attachment 1: Pedestal_with_source_MGX_r517.png
Pedestal_with_source_MGX_r517.png
Attachment 2: Pedestal_with_source_MGY_r517.png
Pedestal_with_source_MGY_r517.png
Fixede768s Fri Feb 14 17:29:06 2020 OttoTimeRUNGeneralN/ATimeCalibratorRun
*** Run Time Calibrator FSC ***
- Run: 511
- MUVI: MUVI2
- Side : MUFEE Y (Ohmic)
- Telescope: 1, 2, 3, 4
Attachment 1: TimeCal_MGY_r511.png
TimeCal_MGY_r511.png
Fixede768s Mon Feb 17 17:10:11 2020 OttoTimeRUNGeneralN/ATimeCalibratorRun
*** Run Time Calibrator FSC ***
- Run: 515
- MUVI: MUVI4
- Side : MUFEE X (Junction)
- Telescope: 1,
Attachment 1: TimeCal_MG9X_r515.png
TimeCal_MG9X_r515.png
Fixede768s Mon Feb 17 17:18:31 2020 OttoTimeRUNGeneralN/ATimeCalibratorRun
*** Run Time Calibrator FSC ***
- Run: 516
- MUVI: MUVI4
- Side : MUFEE Y (Ohmic)
- Telescope: 1,
Attachment 1: TimeCal_MG9Y_r516.png
TimeCal_MG9Y_r516.png