Fixede744s Thu Apr 11 00:57:34 2019 iulianOTHERHardwareCH2CH2 target thicknesstarget CH2 104 um (2nd position)

Brho 14N6+ CATS2 
  
Fixede744s Thu Apr 11 02:25:06 2019 iulianRUNGeneralCH2 target thicknesses measurement OnlineOnline measurement of the target thickness:
Run 58 
Cats2 in -> Brho 14N7+=0.9148 Tm
  
Fixede744s Thu Apr 11 06:48:23 2019 iulianRUNHardwareCH2TO DO list[quote="mugast"]- 2 TACS are not working:

[LIST]
 run275_tacs_mugast.png 
Fixede744s Thu Apr 11 07:00:17 2019 iulianBEAMGeneralCH2ToDo List and plan for todayTo Do/Understand
1) T_Vamos_Cats1 in Mugast and T_FPMW_CATS2
in Vamos are not working. I suspect it is
 run275_tacs_mugast.png 
Fixede744s Thu Apr 11 17:38:28 2019 iulianRUNHardwareEmptySetting trigger Vamos and CatsRemoved division %40000 on Cats and %1000
on Vamos.
  
Fixede744s Fri Apr 12 07:26:29 2019 iulianRUNGeneralCH2Run88Please add all the spectra from the visualization
into the elog and all the scales.... see
runs before
  
Fixede744s Fri Apr 12 13:34:33 2019 iulianOTHERGeneralN/AE744 Status1) Beam tuning during the night.
2) around 04h00 started runs at 4e+4
3) beam intensity decreased to 1e+4 @7h30
  
Fixede744s Sat Apr 13 23:25:14 2019 iulianRUNGeneralN/AInconsistent info in the run messageThis inconsistency has been addressed 
[quote="Adrien Matta"][quote="Adrien Matta"]Be
careful to fill in correctly all info in
  
Fixede768s Thu Jul 18 19:40:11 2019 iulianOFFLINEGeneralLiFEx in 19F from run 72 Excitation energy spectra in 19F obtained
by conditioning Z==9 and (A/Q*8-19)<0.3 in
Vamos for 
 mg5_19F_Ex_run72_0.pngmg11_19F_Ex_run72_0.pngallMugast_deToF_Q9_and8_19FVam_run72_0.pngallBackward_deToF_Q9_and8_19FVam_run72_1.png 
Fixed  Fri Jul 19 11:46:51 2019 iulianOFFLINEGeneralLiFOffline 112Egamma vs M/Q*9 to check who is 19Ne
Ex in 19Ne all Mugast
Ex vs Egamma for 19Ne
 run112_Egamma_mM_Q.pngrun113_Ex_19Ne.pngrun112_Ex_Egamma_19Ne.pngrun112_KinLines_19Ne.png 
Fixede744s Fri Apr 12 13:53:56 2019 diegoOTHERGeneral interventionTAC FPMW_HF in VAMOS was still out of range
for MUGAST physics
We increased the range from 1us to 2us and
  
Fixede744s Fri Apr 12 19:44:09 2019 diegoVAMOSSoftware SetAlias script for VAMOS identification   SetAlias.C 
Fixedcom2019 Sat Apr 6 00:29:14 2019 clementOFFLINEGeneralCD2Experimental Kinematic Line from dp + gamma ?????Triangle is 870 keV  20.png 
Fixede744s Tue Apr 16 15:33:26 2019 beyhan, marion, dieterVAMOSGeneral VAMOS settings fo C run   IMG_1643.jpg 
Fixede744s Tue Apr 16 01:01:42 2019 beyhan, louis, serge, OFFLINEGeneral different parameters evolution as function of intensity   6x 
Fixede744s Tue Apr 16 00:04:08 2019 beyhanOFFLINEGeneral ewire evolution vs beam intensity (normalized to CATS intensity)   EWIRE0_change_122_vs_130_vs_131.pdfEWIRE1_change_122_vs_130_vs_131.pdfEWIRE2_change_122_vs_130_vs_131.pdfEWIRE3_change_122_vs_130_vs_131.pdf 
Fixede768s Fri Jul 19 14:44:30 2019 adrienOTHERHardwareLiFThe diamond detector is not behaving properlyOn the image attached we can see the counting
rate of the diamond (Red) going up linearly
while Vamos (blue) staty stables.
 dimaond_is_not_working.png 
Fixede793s Sat Mar 6 13:10:07 2021 adrienONLINEGeneralN/AFSC screen shot of online at end of runevery detetector have time on either X or
Y except for MM5, which is at 90deg and used
for elastic, so not a deal breaker.
 FSC5-6march.png 
Fixede793s Thu Mar 11 09:04:38 2021 adrienONLINEGeneralCD2Elastic scattering in MM5looking at E vs strip number in MM5 we see
clearly the pp and dd elastic scattering.
 run53_mm5_elastic.png 
Fixede793s Thu Mar 11 04:34:58 2021 ablaihan, louisCATSHardwareCD2CATS and VAMOS trippedat 4h15 CATS and VAMOS tripped probably due
to too high beam intensity (~1.2x10^6 pps).
We switched them on again at 4h30. All the
 Scaler_run53_4h30.png 