MUST2
SAMURAI_2018
S3-LEB-LPC
SUPERNEMO
MUGAST
EXPAND
SCALP
GALATRON
HiCARI
VELO
MUGAST, Page 10 of 132
Not logged in
Find
|
Login
Full
| Summary |
Threaded
2636 Entries
Goto page
Previous
1
,
2
,
3
...
9
, 10,
11
...
130
,
131
,
132
Next
Status
ExpNbr
Date
Author
Type
Category
Target-Source
Subject
Text
Fixed
e744s
Thu Apr 11 00:57:34 2019
iulian
OTHER
Hardware
CH2
CH2 target thickness
target CH2 104 um (2nd position)
Brho 14N6+ CATS2
Fixed
e744s
Thu Apr 11 02:25:06 2019
iulian
RUN
General
CH2
target thicknesses measurement Online
Online measurement of the target thickness:
Run 58
Cats2 in -> Brho 14N7+=0.9148 Tm
Fixed
e744s
Thu Apr 11 06:48:23 2019
iulian
RUN
Hardware
CH2
TO DO list
[quote="mugast"]- 2 TACS are not working:
[LIST]
Fixed
e744s
Thu Apr 11 07:00:17 2019
iulian
BEAM
General
CH2
ToDo List and plan for today
To Do/Understand
1) T_Vamos_Cats1 in Mugast and T_FPMW_CATS2
in Vamos are not working. I suspect it is
Fixed
e744s
Thu Apr 11 17:38:28 2019
iulian
RUN
Hardware
Empty
Setting trigger Vamos and Cats
Removed division %40000 on Cats and %1000
on Vamos.
Fixed
e744s
Fri Apr 12 07:26:29 2019
iulian
RUN
General
CH2
Run88
Please add all the spectra from the visualization
into the elog and all the scales.... see
runs before
Fixed
e744s
Fri Apr 12 13:34:33 2019
iulian
OTHER
General
N/A
E744 Status
1) Beam tuning during the night.
2) around 04h00 started runs at 4e+4
3) beam intensity decreased to 1e+4 @7h30
Fixed
e744s
Sat Apr 13 23:25:14 2019
iulian
RUN
General
N/A
Inconsistent info in the run message
This inconsistency has been addressed
[quote="Adrien Matta"][quote="Adrien Matta"]Be
careful to fill in correctly all info in
Fixed
e768s
Thu Jul 18 19:40:11 2019
iulian
OFFLINE
General
LiF
Ex in 19F from run 72
Excitation energy spectra in 19F obtained
by conditioning Z==9 and (A/Q*8-19)<0.3 in
Vamos for
Fixed
Fri Jul 19 11:46:51 2019
iulian
OFFLINE
General
LiF
Offline 112
Egamma vs M/Q*9 to check who is 19Ne
Ex in 19Ne all Mugast
Ex vs Egamma for 19Ne
Fixed
e744s
Fri Apr 12 13:53:56 2019
diego
OTHER
General
intervention
TAC FPMW_HF in VAMOS was still out of range
for MUGAST physics
We increased the range from 1us to 2us and
Fixed
e744s
Fri Apr 12 19:44:09 2019
diego
VAMOS
Software
SetAlias script for VAMOS identification
Fixed
com2019
Sat Apr 6 00:29:14 2019
clement
OFFLINE
General
CD2
Experimental Kinematic Line from dp + gamma ?????
Triangle is 870 keV
Fixed
e744s
Tue Apr 16 15:33:26 2019
beyhan, marion, dieter
VAMOS
General
VAMOS settings fo C run
Fixed
e744s
Tue Apr 16 01:01:42 2019
beyhan, louis, serge,
OFFLINE
General
different parameters evolution as function of intensity
6x
Fixed
e744s
Tue Apr 16 00:04:08 2019
beyhan
OFFLINE
General
ewire evolution vs beam intensity (normalized to CATS intensity)
Fixed
e768s
Fri Jul 19 14:44:30 2019
adrien
OTHER
Hardware
LiF
The diamond detector is not behaving properly
On the image attached we can see the counting
rate of the diamond (Red) going up linearly
while Vamos (blue) staty stables.
Fixed
e793s
Sat Mar 6 13:10:07 2021
adrien
ONLINE
General
N/A
FSC screen shot of online at end of run
every detetector have time on either X or
Y except for MM5, which is at 90deg and used
for elastic, so not a deal breaker.
Fixed
e793s
Thu Mar 11 09:04:38 2021
adrien
ONLINE
General
CD2
Elastic scattering in MM5
looking at E vs strip number in MM5 we see
clearly the pp and dd elastic scattering.
Fixed
e793s
Thu Mar 11 04:34:58 2021
ablaihan, louis
CATS
Hardware
CD2
CATS and VAMOS tripped
at 4h15 CATS and VAMOS tripped probably due
to too high beam intensity (~1.2x10^6 pps).
We switched them on again at 4h30. All the
Goto page
Previous
1
,
2
,
3
...
9
, 10,
11
...
130
,
131
,
132
Next
ELOG Home Page