MUST2 SAMURAI_2018 S3-LEB-LPC SUPERNEMO MUGAST EXPAND SCALP GALATRON HiCARI VELO
  MUGAST, Page 108 of 132  Not logged in MUGAST
Status ExpNbr Date Authordown Type Category Target-Source Subject Text Attachments
Fixed  Thu Feb 27 15:54:09 2020 Marlène RUNGeneral RUN 141 junk (problem at start)    
FixedTEST Wed Jan 16 16:33:28 2019 MarlèneGRITGeneral3-alphaStatus of detectors on 16/01/19MG1 has some issue with the HT cable (for
the BT bias). There is a shortcut only under
vacuum. We checked the connector but we have
 Detectors_status_160119.xlsxCapture_d’eÌcran_2019-01-16_aÌ€_17.05.57.png 
Fixed  Tue Jan 22 11:15:15 2019 MarlèneGRITGeneralN/ASquare detectorsMG9C (thin square detector coupled with thick
square detector unplugged) noisy
On X channels --> no noise problem ( about
 MG9C_disabled_channels__no_crazy_ORD.pngMG9C_disabled_channels__no_crazy_ORD_moredetailed.pngMG9C_piedestal_of_disabled_channels_Y.png 
Fixed  Wed Jan 23 12:24:10 2019 MarlèneGRITGeneral Change cable MG1T - Exchange of detectors named MG9C & MG10C23/01/19

Change of the HT/BT cable of MG1T (the one
  
Fixed  Fri Jan 25 17:02:25 2019 MarlèneGRITGeneral Detectors numbering   MUGAST_detectors.pdf 
Fixed  Tue Mar 12 10:21:17 2019 MarlèneMUST2General Debug Calimero YDebug of Calimero

test of channels (mate) masking : OK with
 test_GECO_masquage_mate2&10activees_seulement.png 
Fixed  Thu Apr 4 17:55:47 2019 MarlèneGRITGeneral ScalersThe scalers are

Scaler 1:
  
Fixedcom2019 Fri Apr 5 00:47:16 2019 MarlèneOTHERGeneralN/AGame plan   gameplan_comMUGAST.pdf 
Fixede744s Thu Apr 11 02:53:20 2019 MarlèneRUNGeneral TAc VAMOS-CATSJust before RUN 68
TAC VAMOS-CATS is now in TAC CATS1-CATS2
in order to check if we see something in
  
Fixed  Thu Apr 11 05:03:13 2019 MarlèneRUNHardwareCH2TO DO list- 2 TACS are not working: 
[LIST]
[*] T_Si_CATS1 (stop should be CATS n FAG
  
Fixede744s Thu Apr 11 18:08:12 2019 MarlèneOTHERHardware changes in the electronic[quote="Valérian, Chloé and François"]Changes
made in the electronic during the break between
14N and 14O
  
Fixede744s Thu Apr 11 19:47:15 2019 MarlèneOFFLINEGeneral CATS charges in RUN76 and RUN77Offline analysis to reconstruct the charges
in X and Y for CATS.
The charges are lower in RUN77 because bias
 CATS_stripY_run76.pdfCATS_stripX_run76.pdfCATS_stripY_run77.pdfCATS_stripX_run77.pdfCATS_RUN77.pdf 
Fixede744s Fri Apr 12 08:19:31 2019 MarlèneOFFLINEGeneral CATS profiles RUN87   CATS_pos_RUN87.pngCATS_chargeX_run87.pngCATS_chargeX_2_run87.pngCATS_chargeY_run87.pngCATS_ChargeY_2_run87.png 
Fixede744s Fri Apr 12 09:25:10 2019 MarlèneONLINEGeneral TAC   Capture_du_2019-04-12_09-24-34.png 
Fixede744s Mon Apr 15 09:59:32 2019 MarlèneRUNGeneralCH2change thresholds in DSSD MUST2 and suppression CsIFrom RUN126
change of MUST2 DSSD thresholds : thresholds
are 583 keV now
  
Fixede744s Tue Apr 16 11:01:04 2019 MarlèneRUNGeneral statistics on each targetCumulated statistics (evaluated from CATS
trigger) on each target is : 
-target #3 : 7.547e5 (x 30000) 
  
Fixede744s Thu Apr 18 09:28:12 2019 MarlèneMUST2General3-alphaRUN 206 (mugast) 3Alpha calib after e744s experimentRUN 206
3 alpha source all detectors with no change
in the configuration (low thresholds in MUST2)
 run206_calibMMY.pngrun206_calibMGY.pngrun206_calibMMX.pngrun206_calibMGX.png 
Fixede786s Fri May 31 09:53:14 2019 MarlèneGRITGeneral Alpha source --> status of detectorsMG3T has been fixed by changing the X kapton.

I have removed aluminium foil on square detectors,
  
Fixede786s Mon Jun 3 18:00:10 2019 MarlèneGRITGeneral MUGAST detectors status --> MG4T The problem of MG4T ha sbeen solved by changing
the feedthrough.
The pulser on Y was not working and we were
  
Fixede786s Mon Jun 24 03:08:49 2019 MarlèneRUNGeneralCryo-3HeBrho issueWe observe a change in the Brho of VAMOS :
the charged states are divided in 2 !!!
 Brho_vamos.png 

ELOG Home Page