Fixede744s Thu Apr 11 18:20:27 2019 Valerian and DiegoOFFLINESoftwareCH2Timing issue between vamos and mugast
A cut is seen on the TAC between MUGAST and the focal plane multiwire of VAMOS when one select XF or DC0_Y>-1500


Edit: This must be a reconstruction problem as it is not seen in the Raw files (using DC0_X for example)

Edit: This is not only a reconstruction problem as the cut appear again if one select DC0_Y

Edit: We changed VAMOS FAG validation window from 500ns to 800ns
Attachment 1: T_MUGAST_FPMW.png
T_MUGAST_FPMW.png
Attachment 2: T_MUGAST_FPMW1.png
T_MUGAST_FPMW1.png
Fixede744s Thu Apr 11 18:08:12 2019 MarlèneOTHERHardware changes in the electronic

Valérian, Chloé and François wrote:
Changes made in the electronic during the break between 14N and 14O

1) T_VAMOS-CATS1
it was not connected. We added 500 ns delay in CATS1


2) T_CATS1_HF
range changed from 2µs to 200 ns


T_VAMOS-CATS1 is now connected in T_CATS1_CATS2 as posted this night. We have tried to add 500ns more delay (800ns in total) to CATS and it did not work, so we suspected the TAC or ADC. This is why we inverted T_VAMOS-CATS1 with T_CATS1_CATS2. For this TAC, CATS is the START (and is not delayed by 500ns).
Fixede744s Thu Apr 11 17:43:44 2019 OttoRunRUNGeneralEmptyRun80
*************************
Run : 80
*************************

Start at 2019-04-11 17:42:44.178301

Run Conditions:
  • Operator: Adrien
  • Trigger: VAMOS %1
  • Target/Source: hole
  • Beam: 14O
  • Intensity: ~ 5e+3
  • Brho = 0.69186 Tm
  • !CATS/VAMOS (CATS Efficiency)! : XXXX

Comment:
After removing division on Cats and Vamos.
Aligning beam, daq on for online monitoring

Stop at 2019-04-11 18:50:52.122268
Stop comment: Stop to remove target hole
Fixede744s Thu Apr 11 17:38:28 2019 iulianRUNHardwareEmptySetting trigger Vamos and Cats
Removed division %40000 on Cats and %1000 on Vamos.

Removed Cats2 from the beam
Fixede744s Thu Apr 11 17:38:24 2019 mugast (beyhan)BEAMGeneral 14O8+ beam characteristics
Brho 14O8+ = 0.69186 Tm


update Adrien:
La dream team de Division (non) Opération n'arrive pas a mesurer l’énergie en sortie de CIME (WTF??!!)
Du coup ils ont mis une énergie fausse mais avec une super précision de 1.8 Mev/A dans la fiche.

#onlyatganil
Attachment 1: image1.jpeg
image1.jpeg
Attachment 2: IMG_1581.jpg
IMG_1581.jpg
Fixede744s Thu Apr 11 17:37:29 2019 Valérian, Chloé and FrançoisOTHERHardware changes in the electronic
Changes made in the electronic during the break between 14N and 14O

1) T_VAMOS-CATS1
it was not connected. We added 500 ns delay in CATS1 (CATS2 in reality) (48+150ns before)


2) T_CATS1_HF
range changed from 2µs to 200 ns
Fixede744s Thu Apr 11 17:35:21 2019 FrançoisBEAMGeneral 14O beam is in G1 since 17H00
alignment of the beam in VAMOS
intensity ~ 5x10^3 pps
FixedTEST Thu Apr 11 17:30:58 2019 OttoH.V.OTHERHardwareN/AHVM_ERROR
*** hvm watcher error ***
FP_DC1_w1 Slot: 2 (A1821HMP) Channel:0 Vmon: 674.25 V Imon: 0 uA Status: OVER CURRENT

Fixede744s Thu Apr 11 17:08:39 2019 OttoRunRUNGeneralEmptyRun79
*************************
Run : 79
*************************

Start at 2019-04-11 17:08:21.837538

Run Conditions:
  • Operator: Adrien
  • Trigger: VAMOS
  • Target/Source: hole
  • Beam: 14O
  • Intensity: ~ 3e+3
  • Brho = ?? Tm
  • !CATS/VAMOS (CATS Efficiency)! : XXXX

Comment:

Aligning beam, daq on for online monitoring

Stop at 2019-04-11 17:31:48.540765
Stop comment: Entering to Remove CATS2 and remove VAMOS %1000
Fixede744s Thu Apr 11 16:56:34 2019 OttoRunRUNGeneralEmptyRun78
*************************
Run : 78
*************************

Start at 2019-04-11 16:55:28.720017

Run Conditions:
  • Operator: Adrien
  • Trigger: Mugast
  • Target/Source: hole
  • Beam: 14O
  • Intensity: ~ 3e+3
  • Brho = ?? Tm
  • !CATS/VAMOS (CATS Efficiency)! : XXXX

Comment:

Alignign beam, daq on for online monitoring

Stop at 2019-04-11 17:07:49.331973
Stop comment: changing trigger to vamos
Fixede744s Thu Apr 11 16:07:59 2019 Valerian and LouisOFFLINESoftwareCH2HF resolution
Using the value of the HF=83,4ns. We can obtain the calibrated plot of T_CATS2_HF which is joined and gives us roughly a 2-3 ns resolution for the HF
Attachment 1: T_CATS2_HFns.png
T_CATS2_HFns.png
Fixede744s Thu Apr 11 15:16:10 2019 Adrien, Valerian, LouisCATSGeneralCH2run77 CATS efficiency
CATS efficiency has been computed for run 77 using T_FagHF an T_Si_Cats1 with different triggers:

Trigger GATCONF_MASTER<8 (MUST+Mugast) : 94%
Trigger GATCONF_MASTER=4 (MUST) : 99.4%
Trigger GATCONF_MASTER=2 (square) : 85%
Trigger GATCONF_MASTER=1 (trapezoidal+annular) : 22%

The 22% resolution is due to the fact that the trapezoidal detectors are noisy. Doing the same on an analysed run we obtain ~ 85% efficiency
Fixede744s Thu Apr 11 14:03:45 2019 ValerianCATSHardwareN/AIn case of a CATS2 tripped
Currently, CATS2 is inserted, if the window :

CATS2 has tripped appear, one should do the following :

  • Open a terminal
  • Type: HV
  • Username is : admin
  • Password is : admin
  • Press enter twice

The list of channels is going to appear.

  • Using the arrow of the keyboard, go down until you reach cats2
  • then go right until you reach Off
  • press space, the dectector should start ramping up
  • If it trips again, you can try to put voltage to cats1 (right above cats2)

Two possibility :

  • If cats1 trip it is the gas bottle that is empty call : 07 83 34 30 81 (Sebastien)
  • If cats1 doesn't trip try cats2 again, and if it trips lower the voltage of cats2

To lower the voltage of cats2 : go to the left until you reach the first cell after cats2 name and lower the voltage 10 volts and try to start cats2 again.

THEN CLOSE THE TERMINAL
FixedTEST Thu Apr 11 13:55:54 2019 OttoH.V.OTHERHardwareN/AHVM_ERROR
*** hvm watcher error ***
cats2 Slot: 13 (A1835 ) Channel:1 Vmon: 193.6 V Imon: 0 uA Status: INTERNAL TRIP

FixedTEST Thu Apr 11 13:51:54 2019 OttoH.V.OTHERHardwareN/AHVM_ERROR
*** hvm watcher error ***
cats2 Slot: 13 (A1835 ) Channel:1 Vmon: 170.3 V Imon: 0 uA Status: INTERNAL TRIP

FixedTEST Thu Apr 11 13:50:22 2019 OttoH.V.OTHERHardwareN/AHVM_ERROR
*** hvm watcher error ***
cats2 Slot: 13 (A1835 ) Channel:1 Vmon: 0 V Imon: 0 uA Status: INTERNAL TRIP

FixedTEST Thu Apr 11 13:47:10 2019 OttoH.V.OTHERHardwareN/AHVM_ERROR
*** hvm watcher error ***
cats2 Slot: 13 (A1835 ) Channel:1 Vmon: 200.7 V Imon: 0 uA Status: INTERNAL TRIP

Fixede744s Thu Apr 11 13:43:26 2019 ValerianOFFLINESoftwareCH2Target position for 14N runs
Attachment 1: XY_run14N.png
XY_run14N.png
Attachment 2: Xshift_run14N.png
Xshift_run14N.png
Attachment 3: Yshift_run14N.png
Yshift_run14N.png
FixedTEST Thu Apr 11 13:43:20 2019 OttoH.V.OTHERHardwareN/AHVM_ERROR
*** hvm watcher error ***
cats2 Slot: 13 (A1835 ) Channel:1 Vmon: 189.8 V Imon: 0 uA Status: INTERNAL TRIP

FixedTEST Thu Apr 11 13:43:10 2019 OttoH.V.OTHERHardwareN/AHVM_ERROR
*** hvm watcher error ***
cats2 Slot: 13 (A1835 ) Channel:1 Vmon: 541.2 V Imon: 0.9 uA Status: OVER CURRENT