Status ExpNbr Date Authordown Type Category Target-Source Subject Text Attachments
Fixede768s Fri Jul 26 13:48:41 2019 Marlène, Faïrouz, Bertrand & NicolasBEAMGeneral G1 profiler & VAMOS efficiencyFactor of two between the profiler and VAMOS
FP determination of incident beam is now
understood.
  
Fixed  Sun Jul 21 16:51:30 2019 Marlène, Christian, KseniaBEAMGeneral trial of tracking of the implantation of 15OLooking at AGATA count rate, we have seen
that the highest counting rate for 511 keV
line is seen in the inner ring (0*A clusters).
  
Fixede768s Sun Jul 21 16:39:38 2019 Marlène, AntoineBEAMGeneral IMPORTANT :How to send scalers to PCPGo to PCP

Open a terminal
  
Fixede744s Tue Apr 9 18:08:22 2019 Marlène and FrançoisDAQSoftware new inputs in the ADC Mugastnew inputs in the ADC mugast
T_Mugast_HF = input N°2
E_AGATA =  agata 42 = input N°3
  
Fixed  Fri Apr 5 19:05:56 2019 Marlène NicolasGRITGeneral Brho beam & 17OBrho of  16O @ 6 MeV/A after 1mg/cm2 = 0.68906
Brho of 17O for g.s. after 1 mg/cm2=0.71065
Brho of 17O @ 871 keV after 1mg/cm2=0.70831
  
Fixed  Mon Feb 24 22:34:43 2020 Marlène NicolasRUNGeneral Screenshots run 126 (target CD2+Au #2 rotated 180 deg)   run126_theta_Elab.pngrun126_Tof.png 
Fixede775s Thu Feb 27 12:35:39 2020 Marlène NicolasGRITGeneral RUN128-137_138 analysisKinematic lines for the full statistics up
to now
States above E*>7 MeV are cut in the angles
 Elab_Thetalab_RUN128_137_138.pngExEg_RUN128_137_139.pngEx_RUN128_137_138.png 
Fixede786s Mon Jun 24 03:52:11 2019 Marlène MatthieuRUNGeneralCryo-3He3He target filled with 700 mbThe 3He cryo target is filled with a pressure
of 700 mb
The temperature on the target is 5.98K
  
FixedTEST Thu Mar 7 14:02:03 2019 Marlène IulianMUST2GeneralN/Atest of MUST2 electronics Test with pulser at 20 kHz
The OR of MUVI was scaled down by a factor
of 100, to provoke some resets
  
Fixede744s Thu Apr 11 05:08:20 2019 Marlène IulianRUNGeneralCD2Screenshots from RUN 74RUN 74 with 14N beam and CD2 104um target
First screenshots from MUGAST
 8x 
Fixede775s Sun Mar 1 17:04:43 2020 Marlène FrançoisRUNGeneral Preliminary analysis of runs from 128 up to now (169)Preliminary analysis with all stat up to now.  6x 
Fixed  Thu Jul 11 11:40:18 2019 Marlène & FrancoOTHERHardware Some changes in the electronic scheme - We checked the TACs with a time calibrator,
all of them are working. Maybe to check the
ADCs if some timings are not there during
  
FixedTEST Tue Dec 3 18:14:45 2019 Marlène & FrancoGRITHardware Pulser test of new boardThe new board that will be installed for MG2
has been tested and validated with a pulser
outside of the chamber.
  
Fixed  Wed Jan 22 18:39:54 2020 Marlène & FrancoGRITHardware Tests of the new boxThe new box has been tested together with
the new CAEN SY4527 power supply. We connected
a laptop with Linux to the power supply by
 box_pin_map.pdf 
FixedTEST Fri Feb 14 10:49:22 2020 Marlène & FrancoRUNGeneral3-alphaMG11 issuesWe analyzed the behaviour of the annular.
We realized that the 4-peaks behaviour on
X was already present last year but only
  
Fixede775s Tue Feb 25 11:50:16 2020 Marlène & FrancoOFFLINEGeneral PID with gate on T_FPMW_HFThe black points are what remains after putting
the condition abs(T_FPMW_HF-13000)<1000,
for MG1 and the annular.
 MG1_gatetime_run128.pngannular_gatetime_run128.png 
FixedTEST Wed Mar 11 18:12:40 2020 Marlène & FrancoGRITHardwareN/AUpdate on Mugast(Probably) final update of the status of the
detector before the experiment:
  
FixedTEST Thu Mar 12 10:14:02 2020 Marlène & FrancoGRITHardwareN/ADebugging the cooling systemWe realized that the increase of temperature
of MG7 and MG9 during run 600 (alpha calibration)
was due to the fact that a loop of the cooling
  
FixedTEST Thu Mar 12 14:47:59 2020 Marlène & FrancoGRITHardwareN/AMoving MG9 square to MUVI2- Since we are not using MG6 anymore (card
burnt), we replaced it with MG9 on slot 3
of MUVI2. MUVI4 is now unused. We changed
  
Fixede793s Thu Mar 12 14:54:13 2020 Marlène & FrancoGRITGeneral3-alphaRun 0601 - alpha source calibrationWe start the alpha source calibration run
with pedestal suppression (except for MG7
and MG9) and cooling at 0 deg.
 HV_run601.png 