MUST2 SAMURAI_2018 S3-LEB-LPC SUPERNEMO MUGAST EXPAND SCALP GALATRON HiCARI VELO
  MUGAST, Page 100 of 132  Not logged in MUGAST
Status ExpNbr Date Author Type Categorydown Target-Source Subject
Fixede768s Fri Jul 19 01:02:54 2019 mugastOTHERGeneral 15O beam parameters
Brho manip = Brho after target - 2% = 0.556 Tm

RMN = 2821.476 Gauss

Q32 = 15.2 A
Q31 = 16.8 A
Q41 = 148.070 A
Q42 = 217.452 A

Dipole D4p = 187.632 A
Fixede768s Fri Jul 19 01:05:26 2019 mugastRUNGeneral RUN 108
Brho Change to 0.556 Tm

Moving Plate : Final Position +7mm
with 6 kHz

Slowly increasing
Fixede768s Fri Jul 19 01:32:17 2019 OttoRunRUNGeneralLiFRun107
*************************
Run : 107
*************************

Start at 2019-07-19 01:00:49.000867

Stop at 2019-07-19 01:32:18.881037
Stop comment:
Fixede768s Fri Jul 19 01:32:20 2019 OttoRunRUNGeneralLiFRun108
*************************
Run : 108
*************************

Start at 2019-07-19 01:05:04.198626

Stop at 2019-07-19 02:01:09.195123
Stop comment:

Stop at 2019-07-19 02:16:54.064899
Stop comment:
Fixede768s Fri Jul 19 02:19:51 2019 OttoRunRUNGeneralLiFRun110
*************************
Run : 110
*************************

Start at 2019-07-19 02:13:34.456709

RUN 110 Coupled with AGATA

15O : 1e7 pps
Brho 0.656
target 1.25 mg/cm 7LiF
Fixede768s Fri Jul 19 02:22:12 2019 OttoRunRUNGeneralLiFRun111
*************************
Run : 111
*************************

Start at 2019-07-19 02:19:49.799405

JUNK
10 Coupled with AGATA

15O : 1e7 pps
Brho 0.656
target 1.25 mg/cm 7LiF

Stop at 2019-07-19 02:22:24.337284
Stop comment:
Fixede768s Fri Jul 19 02:27:22 2019 OttoRunRUNGeneralLiFRun112
*************************
Run : 112
*************************

Start at 2019-07-19 02:25:09.701469

coupled with AGATA

15O @ 1.5e7 ppps
Brho=0.556
Target : LiF n°1 1.25 mg/cm2

trigger :
MG
square
MM
Vamos%100
BaF2%100

removed suppression of overflow in energy for MM & square

Stop at 2019-07-19 10:07:19.632461
Stop comment:
Fixede768s Fri Jul 19 03:29:58 2019 JennONLINEGeneralLiFScreenshots run 112 overnight
MUGAST and VAMOS screenshots run 112
Fixede768s Fri Jul 19 08:09:21 2019 Jenn, KseniiaOTHERGeneral Overview nightshift run 112
Smooth night, everything was working properly.
Checked agata rootfile to see preliminary gammas.

19Ne 275 state observed

Also 19F (strong 109 state) (fusion-evaporation?)

Check Agata elog for more details.
Fixede768s Fri Jul 19 09:32:45 2019 mugastBEAMGeneralLiFBeam is fluctuating
There was a temporary beam loss during the run 113
Fixede768s Fri Jul 19 09:38:05 2019 mugastGRITGeneralLiFImpact matrix for MUGAST
Fixede768s Fri Jul 19 10:35:05 2019 OttoRunRUNGeneralLiFRun113
*************************
Run : 113
*************************

Start at 2019-07-19 10:35:00.811685

JUNK

Stop at 2019-07-19 10:42:58.694755
Stop comment: type your message here

Stop at 2019-07-19 10:51:03.268053
Stop comment: type your message here
Fixed  Fri Jul 19 11:46:51 2019 iulianOFFLINEGeneralLiFOffline 112
Egamma vs M/Q*9 to check who is 19Ne
Ex in 19Ne all Mugast
Ex vs Egamma for 19Ne
Kinematics Lines drawn over Elab vs Tlab for 19Ne
Fixede768s Fri Jul 19 12:06:44 2019 OttoRunRUNGeneralLiFRun115
*************************
Run : 115
*************************

Start at 2019-07-19 10:53:00.945262

same conditions as before
LiF target
Brho=0556

GMT triggers :
MG
Square
MM
Vamos div
Baf2 div

Beam optimization during this run to try to improve intensity
Fixede768s Fri Jul 19 13:09:14 2019 mugastBEAMGeneralLiFCounting rates as a function of beam intensity
checking counting rates as a function of increasing beam intensity
Fixede768s Fri Jul 19 13:24:01 2019 mugastOFFLINEGeneralLiFg-ray spectrum (run 112) requiring 19Ne in VAMOS
Fixede768s Fri Jul 19 15:11:10 2019 mugastOFFLINEGeneral Procedure for run conversion and analysis
Here is the procedure to convert a run with VAMOS and AGATA data and add those data to the Kinematic plot.

Every 4GB there will be a file change, to see if there is a file change type:

ls -ltrh /data/mugastX/e768s/acquisition/run/

Convert the last 4GB file and add it to the chain through the following steps:

Open a terminal from one of the Mugast computer:
Type: source $HOME/GoToVamosAna
Type: MyVAna -d2Ar -f /data/mugastX/e768s/acquisition/run/run_$$$$-DD-MM-YY.HHhMMmSSs /data/mugastX/e768s/acquisition/run/RootA/r$$$$_000a.root

OR (in case the run is split in more files)

Type: MyVAna -d2Ar -f /data/mugastX/e768s/acquisition/run/run_$$$$-DD-MM-YY.HHhMMmSSs.N /data/mugastX/e768s/acquisition/run/RootA/r$$$$_00Na.root

(If you get the error "Could not find the BrhoRef for the run <RunNr> ", update the ./Calibs/ListBrho.dat file with relevant Brho for RunNr)

Now you would be already able to run npanalysis to analyze the data VAMOS+Mugast with the following procedure:

Type: exit (to exit the VAMOS environment)
Type: lpcgrit (to load the analysis environment)
Type: npp MUGAST
Edit the exe_e768s.sh to specify which runs to analyze. The command should be the following:

npanalysis -D mugast.detector -C Calibration.txt -E ./Reaction/15N7Lit.reaction -T /data/mugastX/e768s/acquisition/run/RootA/r$$$$_00Na.root AD -O run_$$$$_N.root

Type: ./exe_e768s.sh

To convert a run including the AGATA data, the procedure is the following:
Go to the AGATA analysis computer (last on the right close to the window in the acquisition room), open a terminal and type the following commands:

> a4
> t e768s
> cd Replay
>./do_global_replay.sh -run ## (## is the number of the run you want to convert).

When it is finished, copy the root file to the GANIL world:

> mkdir /dataganil/e768s/acquisition/root_agata/run_00##/
> cp ./run_00##/Out/Analysis/Tree_00*.root /dataganil/e768s/acquisition/root_agata/run_00##/.

Now you can analyze the file using npanalysis.
The command in the exe_e768s.sh file should now look like:

npanalysis -D mugast.detector -C Calibration.txt -E ./Reaction/15N7Lit.reaction -T /data/mugastX/e768s/acquisition/root_agata/run_00##/Tree_000N.root TreeMaster -O run_00##_N_agata.root

The run will be created in the ./NPOutputs folder.
Bon courage!
Fixede768s Fri Jul 19 15:15:47 2019 Diego RamosOFFLINEGeneralLiF19Ne identification in VAMOS together with MUGAST
Fixede768s Fri Jul 19 15:18:38 2019 Diego RamosOFFLINEGeneralLiFPosition of 19Ne in dE:E in VAMOS
Conclusion: IC pressure not needed to be reduced.
Fixede768s Fri Jul 19 15:55:38 2019 mugastRUNGeneral Beam is fluctuating
Run 115 stopped at 16h40.

ELOG Home Page