MUST2 SAMURAI_2018 S3-LEB-LPC SUPERNEMO MUGAST EXPAND SCALP GALATRON HiCARI VELO
  MUGAST  Not logged in MUGAST
Entry  Mon Apr 8 08:30:50 2019, iulian, e744s, OTHER, General, Fixed, N/A, E744s to-do list , proposal and other relevant documents Proposal__15F_v6.pdftime_request_E744.pdfe744s.pdf
    Reply  Mon Apr 8 14:41:07 2019, Daniele M, e744s, OTHER, General, Fixed, N/A, PACE4 cross check ------ E744s to-do list , proposal and other relevant documents 
       Reply  Mon Apr 8 15:18:03 2019, Daniele M, e744s, OTHER, General, Fixed, N/A, Br ---- E744s to-do list , proposal and other relevant documents  
          Reply  Tue Apr 9 17:27:33 2019, Daniele M, e744s, OTHER, General, Fixed, N/A, Br ---- E744s to-do list , proposal and other relevant documents  
       Reply  Tue Apr 9 11:40:33 2019, Daniele M, e744s, OTHER, General, Fixed, N/A, 14N PACE4 cross check ------ E744s to-do list , proposal and other relevant documents 
Message ID: 3841     Entry time: Mon Apr 8 08:30:50 2019     Reply to this: 3846
Author: iulian 
ExpNbr: e744s 
Type: OTHER 
Category: General 
Status: Fixed 
Target-Source: N/A 
Subject: E744s to-do list , proposal and other relevant documents 
To do list

- ask final beam energy for the 14O beam (include CATS removal)-> E=7.60 MeV/u Done
- Mount CATS timing (much thinner) at Cats1 position -> no need -> Cats stay as they are
- make a hole target, diameter = 7 mm, thick target (Al?) Done
- dismount targets with gloves due to the contamination done
- mount targets (list ..… + hole target)
Target list ( Hole Target, 104 um CH2 , 100 um CH2, C target 75 um, 104 um CH2 ) done

- remove the Vamos entrance DCs done
- install the VAMOS finger, larger one, no need to change finger, stay as it is
- Id plots with Vamos
- to mount / or not a MCP -> we stay with cats
- Prepare Agata Or - HFpropre and Agata 52 – HFpropre for beam intensity monitoring.
- Solve the MM3 EY problems (see previous elog entry)
- Understand Vamos (40% efficency) (advances) and Agata efficiency (5% efficiency Agata instead of 10%) (seams that maximum efficiency is 8%-9%, despite having 10 % for Europium) for 2H(16O,p)17O
- Make an acq run with Mugast in air to understand if detectors contaminated done with conclusion ??

You will find:
E744s.pdf last infos about E744
Proposal__15F_6.pdf the proposal as it was for 2018 Lise run
time_request_E744.pdf time request for Vamos-Agata run
Attachment 1: Proposal__15F_v6.pdf  270 kB  Uploaded Mon Apr 8 09:32:21 2019  | Hide | Hide all
Proposal__15F_v6.pdf Proposal__15F_v6.pdf Proposal__15F_v6.pdf Proposal__15F_v6.pdf Proposal__15F_v6.pdf
Attachment 2: time_request_E744.pdf  436 kB  Uploaded Mon Apr 8 09:32:47 2019  | Hide | Hide all
time_request_E744.pdf time_request_E744.pdf time_request_E744.pdf time_request_E744.pdf
Attachment 3: e744s.pdf  1.624 MB  Uploaded Mon Apr 8 19:46:35 2019  | Hide | Hide all
e744s.pdf e744s.pdf e744s.pdf e744s.pdf e744s.pdf e744s.pdf e744s.pdf

ELOG Home Page