Fixed, e755, Fri Jun 29 08:06:42 2018, e755 Valérie, RUN, General, Cryo-LH2, Summary- Runs 175 to 184 29x
|
RUNS during night Friday 29th June From 3am to 8am
RUNS 175 to 184 - cf Scalers, and TcatsHF plots
Run 175 start @ 3h38 stop @3h53
...
Run 184 start @ 6h32 stop @8h00
e748 Exxx 6420051 29 juin 03:53 run_0175.dat.29-06-18_03h38m13s
-r--r--r-- 1 e748 Exxx 469369357 29 juin 04:11 run_0176.dat.29-06-18_03h53m49s
-r--r--r-- 1 e748 Exxx 49139791 29 juin 04:27 run_0177.dat.29-06-18_04h23m02s
-r--r--r-- 1 e748 Exxx 348480913 29 juin 04:47 run_0178.dat.29-06-18_04h36m30s
-r--r--r-- 1 e748 Exxx 2982845 29 juin 04:54 run_0179.dat.29-06-18_04h46m53s
-r--r--r-- 1 e748 Exxx 502709413 29 juin 05:11 run_0180.dat.29-06-18_04h53m41s
-r--r--r-- 1 e748 Exxx 197665271 29 juin 05:26 run_0181.dat.29-06-18_05h18m41s
-r--r--r-- 1 e748 Exxx 6603229 29 juin 05:38 run_0182.dat.29-06-18_05h25m17s
-r--r--r-- 1 e748 Exxx 1580317947 29 juin 06:23 run_0183.dat.29-06-18_05h38m50s
-r--r--r-- 1 e748 Exxx 3176650393 29 juin 08:00 run_0184.dat.29-06-18_06h32m14s |
Fixed, e755, Fri Jun 29 08:08:47 2018, e755 Valérie, target :Takeshi, RUN, General, Cryo-LH2, Run 185 13x
|
Run 185 Friday 29th June start@ 8h stop@
All triggers Must2+cats1 and Cats 2 div.
Mean intensity of the beam between 1.5 to 1.8 10**5/s during the run, with large fluctuations. |
Fixed, e755, Fri Jun 29 09:08:50 2018, e755 Valérie, RUN, General, Cryo-LH2, Plots of Must2 and Cats during run 185 14x
|
Run 185 Friday 29th June see entry 742
Mean intensity of the beam between 1.5 to 1.8 10**5/s during the run, with large fluctuations. |
Fixed, e755, Fri Jun 29 09:53:33 2018, e755 Valérie, target :Takeshi, RUN, General, Cryo-LH2, Run 186 problem Numexo-Narval
|
Run 186 Friday 29th June start@ 9h48 stop@9h51
e748 Exxx 551 29 juin 09:50 run_0186.dat.29-06-18_09h48m46s
All triggers Must2+cats1 and Cats 2 div.
Problem ECC error Numexo |
Fixed, e755, Fri Jun 29 10:03:06 2018, e755 Valérie, target :Takeshi, RUN, General, Cryo-LH2, Run 187
|
Run 187 Friday 29th June start@ 9h53 stop@10h05
e748 Exxx 95976431 29 juin 10:05 run_0187.dat.29-06-18_09h53m29s
All triggers Must2+cats1 and Cats 2 div.
Mean intensity of the beam between 1.5 to 1.8 10**5/s down to 10**4, with large fluctuations. |
Fixed, e755, Fri Jun 29 10:41:00 2018, e755 Olivier, Omar, Valérie, target : Nori, Takeshi, RUN, General, Cryo-LH2, Run 188
|
Run 188 Friday 29th June start@10h36 stop@10h40
e748 Exxx 18078991 29 juin 10:40 run_0188.dat.29-06-18_10h35m20s
All triggers Must2+cats1 and Cats 2 div.
starting tuning of 37Ca. Primary beam is too unstable. PCP machine tries to stabilize it (it should take less than one hour). |
Fixed, e755, Fri Jun 29 12:39:34 2018, Louis, OFFLINE, General, Cryo-LH2, Analysis 38Ar(p,t)36Ar run 128 to 156    
|
Here are some plot summarizing the analysis status on the 36Ar(p,t)34Ar channel.
Run concerned: 128-156
Running time: 31 hours
Gates applied:
- Target Impact (from CATS)
- Triton in dE-E
- Incoming 36Ar, TCATS2_HF in [1600;24000]
- Outgoin Z=18, delta_E E
Plots:
- Kinematics, Exitation energy
- Exitation energy per telescope for T1 to T4, with fit for two pics
Remarks:- We are able to distinguish two different states coressponding two known 0+ and 2+ states
- By looking excitation energy telescope by telescope, we can see a shift between T1,2 and T3,4. Again, left right misalignement of MUST2 is highlight
Runs in 26Ar will be helpfull for E tritons calibrations in CsI
|
Fixed, e755, Fri Jun 29 14:00:51 2018, takeshi, RUN, General, Cryo-LH2, summary for 38Ca + liq. H2, updated
|
I would summarize the statistics of 38Ca + liq H2 target measurement.
We have obtained the data of 49.5 hours until 28/6, and we added 3.5 hours more data last night.
See the spreadsheet for detail, such as the runnumber and the number of acquisition trigger.
https://docs.google.com/spreadsheets/d/1yErcQcrXPdJjEOfUd9D9KPWWkWQpw5kX4wFze6vwij4/edit#gid=0 |
Fixed, e755, Fri Jun 29 17:43:46 2018, daisuke, TARGET, General, Cryo-LH2, liquid hydrogen target logger 10x
|
last update at 6 am on June 30 |
Fixed, e755, Sat Jun 30 01:55:35 2018, Daisuke Louis, RUN, General, Cryo-LH2, RUN 191 FIRST PHYSICS RUN IN 37Ca 21x
|
RUN 191:
started at 1:20
Trigger MUST2, CATS1%3*10**3, CATS2%3*10**3
I=1.3uA
Purity = 20%
================================================
Several changed have been made during beam tuning:- Delay have been changed for CATS1-HF and CATS2-HF
- One more CATS1-HF TOF measurement has been added. It's register in the spectra named NP_T_CATS1_HF
- CATS division has been set to 3*10³ of both CATS1 and CATS2
- Beam is made of 37Ca, 36K, 35Ar and 34Cl with in average 20% purity in 37Ca
- CATS1 and 2 tripped because bottle of isobutane was empty. During changing the gaz bottle, gain of strip 13 X of CATS1 changed. Another calibration is probably need for this one
===============================================
NEW PHYSICS IS COMING |
Fixed, e755, Sat Jun 30 03:18:14 2018, louis, Daisuke, RUN, Software, Cryo-LH2, Beam image after retracting CHIO
|
the beam seems more focused after retracting CHIO upstream of M2C. Screenshot taken during RUN 193. |
Fixed, e755, Sat Jun 30 04:54:55 2018, louis, daisuke, RUN, General, Cryo-LH2, RUN 194 45x
|
Continue 37ca data taking. |
Fixed, e755, Sat Jun 30 08:24:07 2018, Freddy, Shumpei, Louis, RUN, General, Cryo-LH2, Run 195    
|
Run 195
start: 8h08
stop: 12h09
37Ca setting
CATS12 ~ 15-20 kHz
- I = 1.4 uA since 7h30 (2 uA during the night) - PCP: source decreasing -working on it
- Estimation of (Transmission * Efficiency_IC) about 64 % (based on ICdE1 vs TCATS1_HF spectrum)
|
Fixed, e755, Sat Jun 30 09:17:25 2018, Louis, OFFLINE, General, Cryo-LH2, Offline analysis of 37Ca(p,d)36Ca reaction 7x
|
Here are some plot summarizing the analysis status on the 37Ca(p,d)36Ca channel. Plots shows performance of the setup in optimal conditions and preli;inary results.
Run concerned: 192-194
Running time: 6 hours
Gates applied:
- Target Impact (from CATS)
- deuton in dE-E
- Incoming 37Ca, TCATS1_HF in [2800;3800]
- Outgoing Z=20 and Z=19
Plots:
- Ion identification in dE-TOF and dE-E
- Light particle identification in dE-E
- Kinematics, Exitation energy and laboratory angle for Gate on Z=20 and Z=19 outgoing nuclei
- Previous results for 38Ca(p,t)36Ca analysis
Remarks:- Particle identification seems OK for light and heavy particles. We are able to reproduce wath we get during 38Ca beam. All component are well separeted
- On the Z=20 gated spectra, one can distinguish two state. Excited state looks like to be at the same position (around 3MeV) than the one found in 38Ca(p,t)36Ca reaction.
- On the Z=19 gated spectra, one can see state. Looks like to be at the same position (around 6MeV) than the one found in 38Ca(p,t)36Ca reaction with the same gate.
Results looks consistent with previous observations. Let's see wath will grown with more data! |
Fixed, e755, Sat Jun 30 11:25:59 2018, Freddy, Shumpei, BEAM, General, Cryo-LH2, Beam profile on the target 
|
The beam profile on the target for each isotope is shown for all trigger and CATS trigger (GATCONF > 500).
X position seems not to depend on the isotope, while Y position depends on the isotope.
Now, 37Ca is a little bit higher form the center of the target, while 36K is almost at the center. |
Fixed, e755, Sat Jun 30 13:25:27 2018, Freddy, Shumpei , RUN, General, Cryo-LH2, Run 196  
|
Run 196
start: 12h09
stop: 15h38
37Ca setting
I = 2 uA
CATS12 ~ 20 kHz |
Fixed, e755, Sat Jun 30 15:07:43 2018, Shumpei, OFFLINE, General, Cryo-LH2, 37Ca (p,d) 36Ca 
|
37Ca (p,d) 36Ca reaction is analyzed (run 191-195).
Gate condition;
1. beam on target by CATS1&2
2. TOF gate for 37Ca
3. recoil deutron gate by MUST2 only T3
4. fragment gate by CHIO and plastic
Only T3 is used for analysis and the angle is intentionally shifted 1.0 deg to match the kinematics for 40Ca (p,d).
Ground and 2+ state of 36Ca are observed in Z=20 gate, while a higher lying state is seen in Z=19 gate.
This result seems to be consistent with that of 38Ca (p,t) 36Ca. |
Fixed, e755, Sat Jun 30 16:04:11 2018, takeshi, Didier, RUN, General, Cryo-LH2, run 197   
|
RUN 197
start: 15h39
stop : 17h38
beam rate 1.7 uA |
Fixed, e755, Sat Jun 30 17:45:17 2018, takeshi, Didier, RUN, General, Cryo-LH2, run 198   
|
RUN 198
start: 17h40
stop : |
Fixed, e755, Sat Jun 30 18:09:53 2018, Nori, BEAM, General, N/A, Brho1 and Brho2 optimization for 37Ca  
|
Summary of Brho1 and Brho2 optimizations for the 37Ca beam.
Attachment 1:
Results of the Brho1 scan. Corresponding LISE run numbers are also shown in the figure.
As the beam intensity was fluctuating, the counting rates were normalized with respect to the intensity.
By changing Brho1, we tried to search for the peak of the 37Ca production. The yield seemed to reach the maximum at around 2.10 Tm,
although sometimes the rates were not reproducible (see the data point of the run 306, for example).
Attachment 2, 3:
Changes of the yield and purity by scanning Brho2. The shaded area corresponds to the width of the slit (shown only for 0%).
They were well optimized at about 1.925 Tm. |
|