Fixede755 Mon Jul 2 07:37:50 2018 LouisOFFLINEGeneralCryo-LH2Background
RUN: 86 to 89
Beam time: 2h30
Beam 40Ca with empty target

Background has been analyzed for 37Capd from run of 40Ca beam on empty target.
Figure shows excitation energy for all Z in 37Ca(p,d), background associated and background substraction

remarks:
As Ionization chamber was not fonctional during 40Ca beam time, it is not possible to apply Z cuts on background. The substraction is so not yet applied in analysis. Solution to reach this goal is under developement
Fixede755 Tue Jul 3 10:47:01 2018 LouisRUNGeneralCryo-LH2Run beam tuning
RUN 236:
started 10h46, stop at 11h09

RUN 237:
started 11h18, stop at 11h20


Beam tunning
Fixede755 Tue Jul 3 11:48:30 2018 LouisRUNGeneralCryo-LH2Run 238 40Ca
RUN 238:

START 11h23 STOP 12h50

Beam: 40Ca at 1.8*10⁵pps
Trigger: T1 to T8, CATS1div, CATS2div, Plastic
Target: LH2
Fixede755 Tue Jul 3 13:37:19 2018 LouisRUNGeneralCryo-LH2RUN 239
Run 239
start at 13h30, stop at 15h18

beam: 40Ca at 2.3*10⁵pps
target: LH2
trigger: T1 to T8, CATS1div, CATS2div,PLASTICdiv
Fixede755 Tue Jul 3 15:22:26 2018 LouisRUNGeneralCryo-LH2RUN 240
Run 240
start at 15h17, stop at

beam: 40Ca at 2*105pps
target: LH2
trigger: T1 to T8, CATS1div, CATS2div,PLASTICdiv
Fixede755 Tue Jul 3 17:54:44 2018 LouisRUNGeneralCryo-LH2Run 241, 242
RUN 241

start at 17h12, stop at 17h35

beam: 40Ca at 1*105pps
target: LH2
trigger: T1 to T8, CATS1div, CATS2div,PLASTICdiv

RUN 242

start at 17h35, stop at

beam: 40Ca at 1*105pps
target: LH2
trigger: T1 to T8, CATS1div, CATS2div,PLASTICdiv
Fixede738 Thu Jul 5 14:12:18 2018 LouisMUST2General3-alphaRUN 253 calib alpha
Fixede748 Sun Jul 2 23:20:43 2017 LISE team JCT+ChrSBEAMGeneralN/AIdentification plot LISE Run 119
Run 119 2nd July started at 22h20 (around)
Lise trigger
PID ED4_TED4HF without wedge
Brho1=Brho2= 2.3869 T.m
FH31 +/-7 mm ; FH43 +/- 4.1mm
270nA ; REd 1/5 L1; 1/15 L2
channels in the plot

12Be TD4HF 3120 cx ; ED4 6140 cx
14B TD4HF 6000 cx ; ED4 9614 cx
16C TD4HF 7953 cx ; ED4 12860 cx
Fixede755 Thu Jun 21 09:16:01 2018 KitamuraTARGETHardwareN/AVapor pressure
Vapor pressures of isobutane and CF4. The paramateres of the Antoine equation were taken from the following NIST
pages.

Isobutane: https://webbook.nist.gov/cgi/cbook.cgi?ID=C75285&Mask=4&Type=ANTOINE&Plot=on
CF4: https://webbook.nist.gov/cgi/cbook.cgi?ID=C75730&Mask=4&Type=ANTOINE&Plot=on

MODIFIED ATTACHMENT FILES: vertical axes were fixed
Fixede748 Sun Jul 9 09:07:31 2017 Jean-Charles Valérie L. Daisuke ShumpeiRUNGeneralCD2Run 376 LISE tuning (underway)
RUN 376 short run to check beam profile during LISE tuning.

9h07 started
9h10 stopped
Fixede748 Sun Jul 9 09:13:54 2017 Jean-Charles Valérie L. Daisuke ShumpeiRUNGeneralCD2Run 377 LISE tuning (underway)
RUN 376. LISE tuning to optimize the beam spot on target. During this run, the beam stop will be moved.

9h12 started
9h35 stopped.
Images from final settings are attached.
Fixede744 Sat May 26 16:31:53 2018 Jaromir, GiuseppeEXL-PPTSoftwareN/AEXL calibration, light leak
Selector.C can be used to adjust energy bad reconstruction in the EXL detectors due to energy leak (see the PDF attached for more information about it) once we already have the coefficients for the energy on EXL crystals. To operate with it, for first calibration coefficient must be deduced. Once it is done the slopes and offset of the calibration have to be inserted in Selector.C file at lines 41 (a[19]) and at line 49 (b[19]). After thqt thresholds must be fixed (line 58, tr[19]) and also gains on the pairs. We deduced gains as the ratio between x-axis and y-axis of each uncalibrated matrix: for each pair (1-2,3-4,5-6,...,17-18) we took the ratio between x=2000;4000;6000 and the respective y value, and y=2000;4000;6000 and the respective x values. taking the averages of those ratios; those were than used as the coefficients R1ex[9] and R2ex[9] in Selector.C (all information on those values and how are used are in EXL.pdf).
Once the variables are set, the program can be executed using the batch file in attachement by typing the line root rootdir/run_number.root -b batch -q from terminal. Here "run_number" is the name of the run to use. It will generate then a .root file (in attachement some output file for run 0430.root). Now the name is "whatever_output.root", and can be changed from "Selector.C"
The program also provides randomization of bins for the operation of sym between contiguous crystals
Fixede738 Wed Jul 11 18:31:23 2018 Jacques, Didier, LouisRUNGeneralCryo-LH2Run 349
Run 349

Start 18h22 Stop 18h47

========================================

Beam: 9C
2.3*10**5pps in CATS1
1.9*10**5pps in CATS2
3.1*10**5pps in CAVIAR
2uA of intensity of the primary beam


CATS1 670V 0.14 ľA
CATS2 650V 0.10 ľA

========================================

Pressure in CAVIAR has been changed from 20mbar to 10mbar because we lost the position correlation with respect to the TOF
Fixede738 Fri Jul 13 21:15:53 2018 J-C, nori, shumpei, takeshi, hide, didier, serge, daisukeRUNGeneralCryo-emptyRUN 375: 12C pilot run
12C beam + empty target after measurement of 9C momentum distribution.
trigger t1-8 + cats 1 2 %30000 + plastic %10000
start 20h47 / stop 21h08
During this run, wien filter was tuned to center the beam vertically. Final setting is 2.5 kV for negative and 2.5 kV for positive.
The run started with a primary beam intensity of 350 enA. We found that CAVIAR is counting too much and leakage current of CATS1 (0.18 micro A) and 2 (0.14 micro A) are higher than in the 9C measurement. We reduced the beam intensity to 220 enA. The leakage current of CATS1 and 2 are 0.10 and 0.08 micro A, respectively. The plastic rate is about 80 kpps.
Fixede738 Fri Jul 13 18:07:04 2018 J-C, cristelle, nori, olivier, daisukeRUNGeneralCryo-emptyRUN 373
12C 5+ beam. CATS2 trigger.
17h29 start
17h41 stop
Fixede738 Fri Jul 13 18:08:31 2018 J-C, cristelle, nori, olivier, daisukeRUNGeneralCryo-emptyRUN 374
12C5+ beam. Trigger T1-8 + CATS1%30000 + CATS2%30000 + Plastic%10000.
Target empty (under cooling).
beam intensity 350 enA
Fente 31 +/-5 mm
Fente 43 +/-10 mm (both H and V)
Beam energy 55.02 MeV/u
Fixede744 Sat May 26 05:16:12 2018 Iulian Valerian, pedja, mihaiTARGETGeneralCH2Target change
Target No 4 is placed in-beam 5h15.
Fixede744 Sat May 26 06:05:13 2018 Iulian Valerian PedjiaTARGETGeneralCH2Target issue No5
In the attached figure it could be seen that with the target No5 (run 2010) lower energy resonances were visible (lower part of the figure), which is not the case with the target No4 (upper part)from run 2013.

GOODFELLOW or mounting error?
Ongoinge744 Tue May 15 21:32:46 2018 Iulian ValerianEXL-PPTGeneral60Corun #300 60 Co source EXL & PPT trigger
Run #300
PPT EXL trigger 60Co

start 21:32:06 15/05/2018
Fixede744 Wed May 16 18:01:47 2018 Iulian ValerianMUST2SoftwareN/AFirst successful Calimero run on T1 voie X run 316
First successful Calimero run on T1 voie X run 316