MUST2 SAMURAI_2018 S3-LEB-LPC SUPERNEMO MUGAST EXPAND SCALP GALATRON HiCARI VELO
  MUST2, Page 35 of 48  Not logged in MUST2
Status ExpNbr Date Authordown Type Category Target-Source Subject
Fixede755 Wed Jun 27 18:34:31 2018 NPTeamOFFLINEGeneralCryo-LH2Update on the offline Analysis for 38Ca pt run 128-156
Fixede738 Wed Jul 11 12:02:14 2018 NPTeamOFFLINEGeneralCryo-LH2Lauching parrallel analysis of multiple run
We made a parralel conversion script in the conversion folder.
You can run up to 5 run in parallel using the command (for run 331-334 in this example):

./ConvertPhysics.sh 331 332 333 334


when the conversion finnished you will have this display:
- Number of transactions: 3

- Number of transactions: 3

- Number of transactions: 3

- Number of transactions: 3

Please do ctrl-C to get out of the script and start again.
Fixede744 Sat May 26 02:39:18 2018 Mihai, PedjaRUNGeneralCH2Run 2011, Target n°5
RUN 2011
Date : 26/05/2018
Beam used: 14O
Start: 2h26
Stop: 4h21


-----------------------------
Missing strips:
x
MM1 1
MM2 6
MM3 0
MM4 2
MM5 0
y:
MM1 3
MM2 1
MM3 0
MM4 7
MM5 3.5
Fixede744 Sat May 26 04:24:16 2018 Mihai, PedjaRUNGeneralCH2Run 2012, Target n°5
RUN 2012
Date : 26/05/2018
Beam used: 14O
Start: 4h23
Stop: 4h57

suspect the target is too thick, low resonances seen... run stopped in order to check it.


-----------------------------
Missing strips:
x
MM1 1
MM2 6
MM3 0
MM4 2
MM5 0
y:
MM1 3
MM2 1
MM3 0
MM4 7
MM5 3
Fixede744 Sat May 26 05:23:12 2018 Mihai, PedjaRUNGeneralCH2Run 2013, Target n°4
RUN 2013
Date : 26/05/2018
Beam used: 14O
Start: 5h18
Stop: 5h48




-----------------------------
Missing strips:
x
MM1 1
MM2 6
MM3 0
MM4 2
MM5 0
y:
MM1 3
MM2 1
MM3 0
MM4 7
MM5 3
Fixede744 Sat May 26 05:51:00 2018 Mihai, PedjaRUNGeneralCH2Run 2014, Target n°4
RUN 2014
Date : 26/05/2018
Beam used: 14O
Start: 5h50
Stop: 7h19

Stopped, because no beam due to a vacuum problem on CSS1



-----------------------------
Missing strips:
x
MM1 1
MM2 6
MM3 0
MM4 2
MM5 0
y:
MM1 3
MM2 1
MM3 0
MM4 7
MM5 3
Fixede738 Sun Jul 15 00:49:52 2018 Megumi, Shumpei, Takeshi, Benoît, ValérieRUNGeneralCryo-emptyRUN 394 9C
9C + Empty target 15th JULY
RUN 394 start 0h43 stop 03h20
e748 Exxx 2,9G 15 juil. 2018 /data/e748X/e755/acquisition/run/run_0394.dat.15-07-18_00h43m25s
SEE OFFLINE PLOTS for the checking of the empty target.
normal TRIGGERS MUST2 CATS div Plastic div
primary beam I ~ 1.85 ľA.

Beam CATS1 ~ 208 kpps ; CATS2 ~ 185 kpps ; Plastic ~ 194 kpps

CATS1 I ~ 0.12 ľA
CATS2 I ~ 0.10 ľA
Fixede738 Sun Jul 15 03:27:25 2018 Megumi, BenoîtRUNGeneralCryo-emptyRUN 395 9C
9C + Empty target 15th JULY
RUN 395 start 03h20 stop 05h59
e748 Exxx 2,8G 15 juil. 06:01 /data/e748X/e755/acquisition/run/run_0395.dat.15-07-18_03h20m21s
normal TRIGGERS MUST2 CATS div Plastic div
primary beam I ~ 1.85 ľA.

Beam CATS1 ~ 203 kpps ; CATS2 ~ 184 kpps ; Plastic ~ 192 kpps

CATS1 I ~ 0.12 ľA
CATS2 I ~ 0.10 ľA

small disjunction on CSS1, beam was erratic for about 15min. Intensity became 1.95 ľA after.
Fixede738 Sun Jul 15 06:17:04 2018 Megumi, BenoîtRUNGeneralCryo-emptyRUN 396 9C
9C + Empty target 15th JULY
RUN 396 start 06h00 stop 7h59

normal TRIGGERS MUST2 CATS div Plastic div
primary beam I ~ 1.85 ľA.

Beam CATS1 ~ 198 kpps ; CATS2 ~ 177 kpps ; Plastic ~ 186 kpps

CATS1 I ~ 0.12 ľA
CATS2 I ~ 0.10 ľA

missing CATS 1 Y 9 which was starting to be bad in run 395
Fixed  Fri May 18 15:17:19 2018 Megumi and LouisOTHERHardware TAC range setting and time calibration
1 mm-cats 1us
2 mm-hf 200ns
3 mm-exl 1us
4 mm-ppt 1us
5 cats-hf 200ns
6 exl-cats 1us
7 ppt-cats 1us
8 mm-mcp 1us
9 mm-hfv 200ns
10 mcp-hf 200ns

time calibrator setting
period 0.02us
range 1.28us

run340 for test
run341 for calibration of mm-cats start
run343 for calibration of mm-hf
run344 for calibration of mm-exl, mm-ppt, mm-mcp, mm-hf, mcp-hfv

added on 21/05/2018
we found validation point was missing for some channels

run349 for calibraion cats_hf
run350 for calibration ppt_cats
run351 for calibraion cats_hf again
run352 for calibration exl_cats



calibration parameter (in ns)
1 mm-cats 0.0495255
2 mm-hf 0.0102974
3 mm-exl 0.0500575
4 mm-ppt 0.0510095
5 cats-hf 0.010322
6 exl-cats 0.0547923
7 ppt-cats 0.051581
8 mm-mcp 0.0507524
9 mm-hfv 0.0107085
10 mcp-hf 0.01041
Fixede755 Tue Jun 26 12:06:41 2018 Marlčne, Yorick, ValérieRUNGeneralCryo-LH2RUN 142
Run 142 26th june start@ 11h15 ; stop @11h27

e748 Exxx 492791993 26 juin 11:27 /data/e748X/e755/acquisition/run/run_0142.dat.26-06-18_11h15m39s
Trigger: all MM + CATS DIV
conditions of the MUST2 pedestals. Before we had:
Mate 1 to 8 seuil haut (high threshold) =8210; seuil bas (low threshold)= 8180
NOW: seuil haut =8210; seuil bas = 0

Fixede755 Tue Jun 26 12:18:08 2018 Marlčne, Yorick, ValérieRUNGeneralCryo-LH2RUN 143
Run 143 -- 26th June start@ 11h30 ; stop @ 11h39
e748 Exxx 306151179 26 juin 11:39 /data/e748X/e755/acquisition/run/run_0143.dat.26-06-18_11h30m28s

Trigger: all MM + CATS DIV
conditions of the MUST2 pedestals. Before we had:
Mate 17 SiLi seuil haut (high threshold) = 8192; seuil bas (low threshold)= 8192
NOW: seuil haut = 8210 ; seuil bas = 0

Fixede755 Tue Jun 26 12:22:56 2018 Marlčne, Yorick, ValérieRUNGeneralCryo-LH2RUN 144
Run 144 -- 26th June start@ 11h51 ; stop @ 13h04

Trigger: all MM + CATS DIV
conditions of the MUST2 pedestals. Before we had:
Mate 9 ŕ 16 Y seuil haut (high threshold) = 8210; seuil bas (low threshold)= 8180
NOW: seuil haut = 16384 ; seuil bas = 8180

Fixede738 Wed Jul 11 07:49:12 2018 Marlčne, Franck, Jacques, DaisukeRUNGeneralCryo-LH2RUN 341
RUn 341
start 7:44 /stop 9h29

CATS2 high voltage 650V (lowered because it tripped) - I= 0.08uA
CATS2 efficiency ~ 50%
Fixede755 Mon Jun 25 11:12:40 2018 Marlene, LouisRUNGeneralCryo-LH2Run 117, 38Ca, Target filled
Run 117 started @ 10h54
stopped @ 11h32 to enter in the room

CAVIAR was tripped and restarted. CAVIAR retripped and re turned on at 655V
Fixede755 Mon Jun 25 13:40:41 2018 Marlene, LouisRUNGeneralCryo-LH2RUN 118 CAVIAR setting
run 118 started @ 13h13
stopped @ 13h43

Tension of CAVIAR setting for high intensity beam.
Stopped to enter in D4 and D6
Fixede755 Mon Jun 25 14:04:17 2018 Marlene, LouisRUNGeneralCryo-LH2RUN 119 to 121
Test for CAVIAR and CHIO:

run 119 with two 1/15 reductors 13h54 to 14h01
run 120 with one 1/15 reductor 14h01 to 14h03
run 121 without reductor 14h04 to 14h13
run 122 without redictor, with CATS1/3*10**4 14h13 to 14h16
Fixede748 Wed Jul 5 14:34:15 2017 MarleneRUNGeneralCD2Run summary 329,330
We thought the merge was broken, but the issue was the Raw Data gruscipt connecting to the wrong port.

Everything reestablished as before.
Fixede738 Wed Jul 11 02:52:54 2018 MarleneRUNGeneralCryo-LH2RUN336
run336 start 1:07 / stop 2:48
fluctuations of beam intensity
Fixede744 Wed May 23 15:42:04 2018 Louis, ValérieMUST2GeneralN/ACALIMERO run 409 - XT - T1 to T4
Started run #409
GMT triggers: GecoCalimeroMuviGMT.png
HT on cf : HTtelescopesMustsWed23May.png
Calimero TC 640ns; period 20ns
XT for T1 to T4 ampli pulser 12MeV
thresholds for telescopes T1 to T3, 400 keV except T4: Threshold 1MeV
cf GecoCalimeroMuviTel4Thr1MeV.png
problem of configuration:
cf configCalim1.png trigger must be external on the calimero pulser interface.
cf good one on the configCalimOkexterne.png (to be done for the next runs)

ELOG Home Page