Status |
ExpNbr |
Date |
Author |
Type |
Category |
Target-Source |
Subject |
Fixed | e755 |
Mon Jun 25 03:58:22 2018 |
Valérie +Target: Takeshi | RUN | General | Cryo-LH2 | RUN 114 |
Run 114 25th June start @ 3h57 stop @5h34
e748 Exxx 4015552641 25 juin 05:34 /data/e748X/e755/acquisition/run/run_0114.dat.25-06-18_03h57m34s
--------------------------------------------------------------------------------
Triggers All Must2 Cats 1 and Cats2 DIV= 3.10**4
I ~2.4 10**5 /s FH43 +/- 5mm ; FV 43 +/- 4.1mm ; FH31 = +/-4mm;
FH62 +/-15 mm; FV62 +11 mm
-------------------------------------------------------------------------------------
Dead time between 20 and 25%
Beam I~ 2.4 10**5 down to 2.2 10**5 at 4h01- see scalers
down to 3. 10**4 at 4h55 then up to 2.3 10**5 at 5h07; 1.6 10**5 at 5h30
------------------------------------------------------------------------------
|
Attachment 1: Run114ScalersAt4h01.png
|
|
Attachment 2: Run114CATSchargeRaw.png
|
|
Attachment 3: Run114CATSchargecal.png
|
|
Attachment 4: Run114DCnumexoPhys.png
|
|
Attachment 5: Run114IC0degcatsCaviar.png
|
|
Attachment 6: Run114ICorrelPIDicDeTOF.png
|
|
Attachment 7: Run114MMimpacts.png
|
|
Attachment 8: Run114NPscalersAt4h25.png
|
|
Attachment 9: Run114ScalersAt5h30.png
|
|
Fixed | e755 |
Mon Jun 25 05:34:53 2018 |
Valérie +Target: Takeshi | RUN | General | Cryo-LH2 | RUNS 115, 115.1 and 116 |
Run 115 25th June start @ 5h34 stop@6h57
e748 Exxx 4190541701 25 juin 06:57 /data/e748X/e755/acquisition/run/run_0115.dat.25-06-18_05h34m33s
-------------------------------------------------------------------------------
Run 115.1 25th June start @ 6h57 stop@ 8h15
r--r--r-- 1 e748 Exxx 4003567657 25 juin 08:15 /data/e748X/e755/acquisition/run/run_0115.dat.25-06-18_05h34m33s.1
--------------------------------------------------------------------------------
Run 116 25th June start @ 8h15 stop@ 10h53
-rw-r--r-- 1 e748 Exxx 95322557 25 juin 2018 /data/e748X/e755/acquisition/run/run_0116.dat.25-06-18_08h14m39s
--------------------------------------------------------------------------------
--------------------------------------------------------------------------------
Triggers All Must2 Cats 1 and Cats2 DIV= 3.10**4
I ~2.4 10**5 /s FH43 +/- 5mm ; FV 43 +/- 4.1mm ; FH31 = +/-4mm;
FH62 +/-15 mm; FV62 +11 mm
-------------------------------------------------------------------------------------
Dead time between 17 to 26% for I between 1.5 and 1.7 10**5/s on CATS1 and 2
Beam I~ 1.6 10**5 at 5h37
Beam I~ 2.7 10**5 at 6h39 ;dead time ~ 16 to 30%.
Stopped cause noticed that there was no CAVIAR anymore
------------------------------------------------------------------------------
|
Attachment 1: Run115ScalersAt5h37.png
|
|
Attachment 2: Run115ScalersAt6h39.png
|
|
Attachment 3: Run115b1_scalersAt7h20.png
|
|
Attachment 4: Run115b1BeamProfile.png
|
|
Attachment 5: Run116_ScalersAt8h26.png
|
|
Fixed | e755 |
Mon Jun 25 07:41:54 2018 |
e755- Valérie | MUST2 | Hardware | Cryo-LH2 | SUMMARY-Missing strips MUST2 |
Telescopes MM1 to MM8, XY ET missing strips
----------------------------------------------------
MM1-XE - X1, X30, X34, X44, X64, X121, X126
MM1-YE - Y25, Y47, Y48, Y124
----------------------------------------------------
MM2-XE - X3, X4, X5, X6, X8, X22, X26, X31, X39, X46, X47, X69, X70, X77
MM2-YE - Y69, Y70, Y100
----------------------------------------------------
MM3-XE - none
MM3-YE - Y93
----------------------------------------------------
MM4-XE - X35
MM4-YE - Y123, Y126
----------------------------------------------------
MM5-XE - X19, X20, X22, X23, X48
MM5-YE - Y34, Y46, Y49, Y65, Y66, Y67, Y69, Y71, Y73, Y75, Y77, Y96, Y98, Y119, Y125
----------------------------------------------------
MM6-XE - X40, X110, X111, X113, X114, X1199, X120, X121, X122
MM6-YE - Y18, Y98
----------------------------------------------------
MM7-XE - X12, X13, X27, X78
MM7-YE - Y24, Y58, Y59
----------------------------------------------------
MM8-XE - X67, X68
MM8-YE - Y96, Y113
----------------------------------------------------
|
Attachment 1: Run116_MMimpacts.png
|
|
Attachment 2: Run116_Mm1toMM4StrXYE.png
|
|
Fixed | e755 |
Mon Jun 25 08:38:34 2018 |
e755 Louis Francois Marlene | OFFLINE | General | Cryo-LH2 | 38Ca(p,d)37Ca |
Here Kine;atics line for th 38Ca(p,d)37Ca Channel from run 110 |
Attachment 1: 38Capd_Run_110.pdf
|
|
Attachment 2: 38Capd_Run_110_deE.pdf
|
|
Fixed | e755 |
Mon Jun 25 10:42:47 2018 |
daisuke | TARGET | Software | Cryo-empty | RUN 106 (38Ca with empty target) S/N |
p, d, t ratio of events from the target frame and from the target aperture (covered by Havar 6.5 micron and Mylar 2 micron)
R(d/p) = 0.3 (frame) 0.14 (target)
R(t/p) = 0.1 (frame) 0.07 (target)
The target cell produce less deuterons and tritons compared to the target frame.
The target cell also produce more particles within one event (or the multiplicity is higher). |
Attachment 1: screenshot_2018-06-25_10h26m17s.png
|
|
Attachment 2: screenshot_2018-06-25_10h27m37s.png
|
|
Attachment 3: screenshot_2018-06-25_10h36m15s.png
|
|
Attachment 4: screenshot_2018-06-25_10h27m26s.png
|
|
Attachment 5: screenshot_2018-06-25_10h37m16s.png
|
|
Attachment 6: screenshot_2018-06-25_14h41m23s.png
|
|
Attachment 7: screenshot_2018-06-25_14h41m35s.png
|
|
Fixed | e755 |
Mon Jun 25 11:12:40 2018 |
Marlene, Louis | RUN | General | Cryo-LH2 | Run 117, 38Ca, Target filled |
Run 117 started @ 10h54
stopped @ 11h32 to enter in the room
CAVIAR was tripped and restarted. CAVIAR retripped and re turned on at 655V |
Attachment 1: Run117_CATS_RAW.png
|
|
Attachment 2: Run117_CATStraj.png
|
|
Attachment 3: Run117_Odegres.png
|
|
Attachment 4: Run117_T8CATS_HF.png
|
|
Attachment 5: Run118_de_tof.png
|
|
Attachment 6: Run118_Scalers.png
|
|
Fixed | e755 |
Mon Jun 25 11:23:03 2018 |
daisuke | TARGET | Hardware | Cryo-LH2 | Liquid hydrogen target logger |
|
Attachment 1: screenshot_2018-06-25_11.17.25.png
|
|
Fixed | e755 |
Mon Jun 25 13:40:41 2018 |
Marlene, Louis | RUN | General | Cryo-LH2 | RUN 118 CAVIAR setting |
run 118 started @ 13h13
stopped @ 13h43
Tension of CAVIAR setting for high intensity beam.
Stopped to enter in D4 and D6 |
Fixed | e755 |
Mon Jun 25 14:04:17 2018 |
Marlene, Louis | RUN | General | Cryo-LH2 | RUN 119 to 121 |
Test for CAVIAR and CHIO:
run 119 with two 1/15 reductors 13h54 to 14h01
run 120 with one 1/15 reductor 14h01 to 14h03
run 121 without reductor 14h04 to 14h13
run 122 without redictor, with CATS1/3*10**4 14h13 to 14h16 |
Fixed | e755 |
Mon Jun 25 16:09:24 2018 |
Benoit Louis | RUN | General | Cryo-LH2 | Beam and CHIO tunning |
During run 126:
Beam was tuned to be centered and homogeneous in the target
efficiency and resolution of the CHIO was improved |
Attachment 1: Run126_deTOF.png
|
|
Attachment 2: Run127_BeamProfil.png
|
|
Attachment 3: Run126_Scaler.png
|
|
Fixed | e755 |
Mon Jun 25 17:23:49 2018 |
Cherry Mx Team | CATS | General | Cryo-LH2 | Confirmation of CATS reconsctruction |
Gating on T1 to T4 and looking at the the CATS reconstruction on Target we confirm that;
- CATS is correlated to MUST
- Telescope Position matches CATS Position, so Telescope numerotation is correct and there is no inversion in CATS.
In attached picture you can see CATS position on target gated by:
- Red: T1
- Green: T2
- Violet: T3
- Noir: T4 |
Fixed | e755 |
Mon Jun 25 17:27:59 2018 |
Cherry Mx Team | CATS | General | Cryo-LH2 | Confirmation of CATS reconsctruction |
Gating on T1 to T4 and looking at the the CATS reconstruction on Target we confirm that;
- CATS is correlated to MUST
- Telescope Position matches CATS Position, so Telescope numerotation is correct and there is no inversion in CATS.
In attached picture you can see CATS position on target gated by:
- Red: T1
- Green: T2
- Violet: T3
- Noir: T4
Second plot with MUST reconstruct coordinate. All is consistent. |
Attachment 1: CATS_TELESCOPE.png
|
|
Attachment 2: CATS_TELESCOPE_M2.png
|
|
Fixed | e755 |
Mon Jun 25 17:28:03 2018 |
Nori | TARGET | Hardware | Cryo-LH2 | Liquid hydrogen target logger |
There was a sudden increase of the temperature at 4pm. Fortunately the cell is still filled with liquid. |
Attachment 1: screenshot_2018-06-25_17.20.41.png
|
|
Attachment 2: screenshot_2018-06-25_20.56.47.png
|
|
Fixed | e755 |
Mon Jun 25 17:31:27 2018 |
daisuke, benoït | TARGET | Software | Cryo-LH2 | RUN 127 (Still filled with liquid? test with Wien filter) |
Beam spot is now too small to see the cell frames. Moved the beam spot down and up by using the Wien filter. It is not conclusive, but the gap between the cell frame and the liquid surface is increasingly apart toward outside in X. It is possible that liquid filling the upper part of the cell has been evaporated. Should carefully monitor the cell temperature and the beam image. |
Attachment 1: Run127_BeamProfil.png
|
|
Attachment 2: visu_2018-06-25_16h55m02s.png
|
|
Attachment 3: visu_2018-06-25_17h01m48s.png
|
|
Attachment 4: Run127_target_frame_projection.png
|
|
Fixed | e755 |
Mon Jun 25 17:40:44 2018 |
daisuke, benoït | RUN | Software | Cryo-LH2 | RUN 128 (Still filled with liquid?) |
|
Attachment 1: visu_2018-06-25_17h21m26s.png
|
|
Attachment 2: visu_2018-06-25_17h38m50s.png
|
|
Attachment 3: visu_2018-06-25_17h57m59s.png
|
|
Attachment 4: visu_2018-06-25_18h08m41s.png
|
|
Attachment 5: visu_2018-06-25_18h17m46s.png
|
|
Attachment 6: visu_2018-06-25_18h29m42s.png
|
|
Attachment 7: visu_2018-06-25_18h39m24s.png
|
|
Attachment 8: visu_2018-06-25_18h49m38s.png
|
|
Attachment 9: visu_2018-06-25_18h59m19s.png
|
|
Attachment 10: scaler_2018-06-25_18h59m20s.png
|
|
Fixed | e755 |
Mon Jun 25 19:59:55 2018 |
marlène, freddy, benoït | MUST2 | Software | N/A | CsI disabled in MUVI/DAS |
|
Attachment 1: das_2018-06-25_19h59m19s.png
|
|
Fixed | e755 |
Mon Jun 25 20:01:07 2018 |
olivier, daisuke | DAQ | Hardware | N/A | Another deat time scaler |
After RUN 128, we entered D6 to add another deat time measuring pulses to U2M channel 9. This is supposed to correctly measure dead time both for MUVI1 in the master and MUVI2 in the slave. For detail, see page 85 in the logbook.
The new dead time scaler counts at nearly the same rate as the originial dead time scaler. We could not see a meaningful difference. |
Fixed | e755 |
Mon Jun 25 20:10:21 2018 |
daisuke, benoît | RUN | General | Cryo-LH2 | RUN 130 |
|
Attachment 1: scaler_2018-06-25_20h10m53s.png
|
|
Attachment 2: visu_2018-06-25_20h09m45s.png
|
|
Fixed | e755 |
Mon Jun 25 20:51:28 2018 |
daisuke, benoît | RUN | General | Cryo-LH2 | RUN 132 |
Previous run (RUN 131), MUST2 threshold was raised to 500 keV to see how the dead time (DESC/ORDD) is improved (found not effective). The threshold was set back to 400 keV. |
Attachment 1: scaler_2018-06-25_20h50m56s.png
|
|
Attachment 2: visu_2018-06-25_20h59m54s.png
|
|
Attachment 3: visu_2018-06-25_21h09m11s.png
|
|
Attachment 4: visu_2018-06-25_21h29m33s.png
|
|
Attachment 5: visu_2018-06-25_21h39m48s.png
|
|
Attachment 6: visu_2018-06-25_21h49m43s.png
|
|
Attachment 7: visu_2018-06-25_22h10m53s.png
|
|
Attachment 8: visu_2018-06-25_22h07m58s.png
|
|
Attachment 9: visu_2018-06-25_22h30m18s.png
|
|
Fixed | e755 |
Mon Jun 25 22:40:38 2018 |
daisuke, benoît | RUN | General | Cryo-LH2 | Run 133 |
same as before |
Attachment 1: scaler_2018-06-25_22h42m05s.png
|
|
Attachment 2: visu_2018-06-25_22h51m13s.png
|
|
Attachment 3: visu_2018-06-25_23h00m38s.png
|
|
Attachment 4: visu_2018-06-25_23h12m25s.png
|
|
Attachment 5: visu_2018-06-25_23h12m37s.png
|
|
Attachment 6: scaler_2018-06-25_23h25m25s.png
|
|