Status |
ExpNbr |
Date |
Author |
Type |
Category |
Target-Source |
Subject |
Fixed | e738 |
Sat Jul 14 00:32:55 2018 |
Shumpei | OFFLINE | General | Cryo-empty | empty target analysis for 9C beam setting |
H2 filled: run0312-0355
empty: run0370-0372
Scale factor for empty run is 10.0
Gate for target position and recoil pid (deuteron or triton)
Gate for theta_cm < 60 deg.
For (p,t) reaction, proton elastic scattering of beam triton contamination cannot be subtracted.
See entry 864
https://elog.lpc-caen.in2p3.fr/MUST2/864 |
Attachment 1: pd.pdf
|
|
Attachment 2: pd_60deg.pdf
|
|
Attachment 3: pt.pdf
|
|
Attachment 4: pt_60deg.pdf
|
|
Fixed | e744 |
Wed May 16 17:03:18 2018 |
Ruxandra | EXL-PPT | Software | | calibration |
Calibration coefficients for the PPT detector using the 60Co and 40K lines: E=0.5514*ch - 83.322. Internal radioactivity at 1444 keV, not separated from 40K
Efficiency: During the run (21h46min40s) the number of gammas emitted from the 60Co source is 66796800; for the Co pics the integrals are: 2.71e05 for the 1173.2 and 1.87e05 for the 1333, respectively (0.4% and 0.3%) without geometrical factor |
Fixed | e744 |
Fri May 18 10:47:37 2018 |
Ruxandra | EXL-PPT | Hardware | 60Co | Co60 caliibration |
Thu May 17 . run 339
60Co calibration
start @19h26 17/05/18
stop @7h39 18/05/18
EXL + PPT trigger |
Fixed | e744 |
Fri May 18 13:28:24 2018 |
Ruxandra | EXL-PPT | Software | 60Co | new calibration |
The new calibration coefficients for the PPT detector (run 339): E=0.526*ch+32.57 |
Fixed | e755 |
Tue Jun 26 07:24:59 2018 |
Pierre, Shumpei, Yorick, Valérie | RUN | General | Cryo-LH2 | RUN 139 |
start: 07h23
stop: 8h52
748 Exxx 3003199093 26 juin 08:52 /data/e748X/e755/acquisition/run/run_0139.dat.26-06-18_07h22m11s
Trigger: all MM + CATS DIV
Beam= 1.6x10^5 pps fluctuating down to 1.0 10**5/s at 8h06
Scalers at 8h42 beam 1.3 10**5/s |
Attachment 1: scaler_2018-06-26_07h23m43s.png
|
|
Attachment 2: visu_2018-06-26_07h26m37s.png
|
|
Attachment 3: run139_scalersAt8h42.png
|
|
Fixed | e755 |
Tue Jun 26 00:09:40 2018 |
Pierre, Shumpei | RUN | General | Cryo-LH2 | RUN 134 |
Start: 26/06 at 00h05
Stop: 00h40 for PCP to improve beam tuning
Beam is back after some tunning.
Trigger: MM+CATS DIV
Beam intensity about 2x10^5 pps |
Attachment 1: scaler_2018-06-26_00h08m24s.png
|
|
Attachment 2: visu_2018-06-26_00h08m16s.png
|
|
Attachment 3: visu_2018-06-26_00h42m01s.png
|
|
Fixed | e755 |
Tue Jun 26 01:02:42 2018 |
Pierre, Shumpei | RUN | General | Cryo-LH2 | RUN 135 |
start: 01h02
stop: 01h39
Trigger: MM+CATS DIV
Beam = 2x10^5; pps |
Attachment 1: scaler_2018-06-26_01h02m13s.png
|
|
Attachment 2: visu_2018-06-26_01h04m13s.png
|
|
Fixed | e755 |
Tue Jun 26 01:46:56 2018 |
Pierre, Shumpei | RUN | General | Cryo-LH2 | RUN 136 |
start: 01h41
stop: 03h37
!!!!!!!!!
New signal from CAVIAR has been shifted by 50 ns.
=> TAC_CATS_CAVIAR is now qlso shifted => new cut condition will have to be applied for run 136 |
Attachment 1: scaler_2018-06-26_01h44m28s.png
|
|
Attachment 2: visu_2018-06-26_01h47m09s.png
|
|
Attachment 3: visu_2018-06-26_02h53m01s.png
|
|
Fixed | e755 |
Tue Jun 26 03:40:15 2018 |
Pierre, Shumpei | RUN | General | Cryo-LH2 | RUN 137 |
start: 03h38
stop: 05h30
Same condition as before
Trigger: MM + CATS DIV
Beam = 2x10^5 pps |
Attachment 1: scaler_2018-06-26_03h38m54s.png
|
|
Attachment 2: visu_2018-06-26_03h42m20s.png
|
|
Attachment 3: visu_2018-06-26_04h05m34s.png
|
|
Fixed | e755 |
Tue Jun 26 05:32:35 2018 |
Pierre, Shumpei | RUN | General | Cryo-LH2 | RUN 138 |
start: 05h31
stop: 07h23
Trigger: MM + CATS DIV
Beam = 2x10^5 pps |
Attachment 1: scaler_2018-06-26_05h32m06s.png
|
|
Attachment 2: visu_2018-06-26_05h36m34s.png
|
|
Fixed | e755 |
Mon Jul 2 16:50:10 2018 |
Pierre, Louis | RUN | General | Cryo-LH2 | Run 231 |
start: 16h47
stop: 18h48
Beam= 26000 pps |
Attachment 1: scaler_2018-07-02_16h51m31s.png
|
|
Attachment 2: visu_2018-07-02_16h52m17s.png
|
|
Fixed | e738 |
Mon Jul 9 15:43:50 2018 |
Pierre Valérie | RUN | General | Cryo-empty | Run 309 |
start: 15h36
stop: 16h10
Trigger: OR MM, CATS1 DIV and PLASTIC%
large beam interuption between 15h40 and 16h06 |
Attachment 1: scaler_2018-07-09_15h38m55s.png
|
|
Attachment 2: scaler_2018-07-09_16h10m56s.png
|
|
Fixed | e755 |
Sat Jun 23 00:47:19 2018 |
Pierre Valerian | CATS | General | N/A | NEW GOOD mask reconstruction |
New shift for CATS after fixing Z position of CATS detectors.
ConfigCATS
ZPROJ -824
ZPROJ -1332
SHIFT_CATS CATS1X -2.3
SHIFT_CATS CATS1Y -3.9
SHIFT_CATS CATS2X 4.5
SHIFT_CATS CATS2Y -2.2 |
Attachment 1: mask1.pdf
|
|
Attachment 2: mask2.pdf
|
|
Fixed | e755 |
Wed Jun 27 22:11:20 2018 |
Pierre Louis | OFFLINE | General | Cryo-LH2 | Offline analysis of 38Ca(p,d)37Ca |
Here are some plot summarizing the analysis status on the 38Ca(p,d) channel.
Run concerned: 128-156 (from 25/06 @ 17h11 to 27/06 @ 7h03)
Running time: 33 hours
Gates applied:
- Target Impact (from CATS)
- Deuton in dE-E
- Incoming 38Ca, TCATS2_HF in [200;1000]
- Outgoing (Z=20)Ca, dE-E (IC-PL)
We analysed statistics in the Ground States of 38Ca(p,d) and compared to statistics of the 38Ca(p,t) channel telescope by telescope
38Ca(p,t)36Ca:
T1: mean = -0.84
sigma = 0.608
Count number = 302
T2: mean = -1.06
sigma = 0.76
Count number = 238
T3: mean = -1.70
sigma = 0.77
Count number = 342
T4: mean = -1.57
sigma = 1.21
Count number = 271
TOTAL_t_GS = 1153
38Ca(p,d)37Ca:
T1: mean = 0.71
sigma = 0.73
Count number = 2868
T2: mean = 0.18
sigma = 0.66
Count number = 1828
T3: mean = 0.23
sigma = 0.81
Count number = 3536
T4: mean = 0.127
sigma = 0.88
Count number = 3240
TOTAL_d_GS = 11472
Remarks:
- see 10 times more statistics in the ground states of 37Ca than in 36Ca
- resolution of the t channel is 80% of the resolution of the d channel
- excited states in (p,d) channel are more populated than the ground state
|
Attachment 1: 38Ca_pd_128_156.png
|
|
Attachment 2: 38Ca_pd_128_156_kinematics.png
|
|
Fixed | e755 |
Mon Jul 2 23:09:55 2018 |
Pierre Louis | OFFLINE | General | Cryo-LH2 | 37Ca(p,d)36Ca |
|
Attachment 1: 37Ca_pd_192_231.pdf
|
|
Fixed | e755 |
Fri Jun 22 21:29:05 2018 |
Pierre Fairouz Adrien Valerian | CATS | General | N/A | Mask reconstruction |
Mask reconstruction after adding the correction shift for CATS.
CATS1X = +1.2
CATS1Y = -0.1
CATS2X = 2.0
CATS2Y = -0.2 |
Attachment 1: mask1.pdf
|
|
Attachment 2: mask2.pdf
|
|
Fixed | e738 |
Mon Jul 9 08:55:13 2018 |
Pierre Daisuke | RUN | General | Empty | Run 303 |
start: 08h27
stop: 08h50
Run for background with no beam |
Fixed | e738 |
Mon Jul 9 08:56:50 2018 |
Pierre Daisuke | RUN | General | Cryo-empty | Run 304 |
start: 08h54
stop: 10h00
Run with same trigger but empty target
TRIGGER: MMi, CATS1DIV, CATS2DIV, PLASTIC% |
Attachment 1: scaler_2018-07-09_08h57m21s.png
|
|
Attachment 2: visu_2018-07-09_09h03m24s.png
|
|
Attachment 3: visu_2018-07-09_09h03m30s.png
|
|
Attachment 4: visu_2018-07-09_09h04m05s.png
|
|
Attachment 5: visu_2018-07-09_09h04m21s.png
|
|
Fixed | e744 |
Fri May 25 18:15:41 2018 |
Pierre | MUST2 | General | CD2 | new dEE PID using Shumpei calibration |
|
Attachment 1: PID_dEE_newCsIcalib.png
|
|
Fixed | e755 |
Tue Jun 26 05:40:52 2018 |
Pierre | OFFLINE | General | Cryo-LH2 | Kinematic lines and Ex for 38Ca(p,d) and 38Ca(p,t) |
-> 38Ca(p,d) uses run 128
-> 38Ca(p,t) uses run from 128 up to 136
The macro to plot them are located in /home/e748/analysis/nptool/Projects/e755/Analysis/macro
- ShowResult_pd.C
- ShowResult_pt.C |
Attachment 1: kine_38Capd_run0128.pdf
|
|
Attachment 2: kine_38Capt.pdf
|
|